Honeywell VISTA-10P Go/No Go Test Mode, Dialer Communication Test and Periodic Test Reports

Page 60

Installation Instructions

NOTES: • All BR type units must physically be activated to clear the display.

When one button of a transmitter (RF, UR, or BR) is activated, all zones assigned to other buttons on that transmitter are cleared. This also applies to 5816 and 5817 transmitters, which have multiple loops (zones).

Any transmitter that is not “enrolled” will not turn off its zone number.

Go/No Go Test Mode

The Go/No Go Test verifies adequate RF signal strength from the proposed transmitter location, and allow you to reorient or relocate transmitters if necessary, before mounting the transmitters permanently. This mode is similar to the Transmitter Test mode, except that the wireless receiver gain is reduced. This will enable you to make sure that the RF signal from each transmitter is received with sufficient signal amplitude when the system is in the normal operating mode.

1.Enter [Installer code] + [#] + 4.

2.After you have placed transmitters in their desired locations and the approximate length of wire to be run to sensors is connected to the transmitter's screw terminals (if used), fault each transmitter. Do not conduct this test with your hand wrapped around the transmitter.

a.The keypad beeps three times to indicate signal reception and displays the unit’s zone number.

b.If the keypad does not beep, you should reorient or move the transmitter to another location. Usually a few inches in either direction is all that is required.

4.If each transmitter produces the proper keypad response when it is faulted, you can then permanently mount each of the transmitters according to the instructions provided with them.

5.Exit the Go/No Go Test mode by entering: any user code + OFF.

Dialer Communication Test and Periodic Test Reports

The following steps can be followed to manually test communication to the central station. 1. Enter Installer Code + 5 [TEST], then press “1” at the prompt to start the Dialer Test.

1=DIAL, 0=WALK

(no special display on Fixed-Word Display Keypads)

The following will be displayed (accompanied by 2 beeps) if test is successful:

PHONE OKAY

(“Cd” displayed on Fixed-Word Display Keypads) A Contact ID report will also be sent (code 601)

If the dialer test is unsuccessful, the following is displayed:

COMM FAILURE

(“FC” displayed on Fixed-Word Display Keypads)

2. Enter Installer code + OFF to clear the display and exit.

Automatic Periodic Test Report

The system can be set to automatically send test reports (enabled in field *64; Contact ID code 602) at specified intervals.

Frequency of the reports is set in Scheduling mode (event 11) or by the following key commands:

installer code + [#] + 0 + 0 = test report sent every 24 hours installer code + [#] + 0 + 1 = test report sent once per week installer code + [#] + 0 + 2 = test report sent every 28 days

Each mode sets schedule 2 to the selected repeat option; first test report sent 12 hours after command. To ensure that test reports are sent at the times expected, set the Real-Time Clock to the proper time before entering the test report schedule command.

Automatic Standby Battery Tests

1.An automatic test is conducted every 3 minutes to ensure that a standby battery is present and properly connected. If a battery is not present or is not properly connected, a “LOW BATTERY” message is displayed and, if so programmed, will be reported to the central station.

2.A battery capacity test is automatically conducted for 2 minutes every 4 hours, beginning 4 hours after exiting the Programming mode or after powering up the system. In addition, entry into the Test mode will also cause a battery capacity test to be initiated. If the battery cannot sustain a load, a “Low Battery” message is displayed and, if so programmed, will be reported to the central station.

7-2

Image 60
Contents Ademco VISTA-10P Ademco VISTA-10PSIA Recommendations for Proper Protection Table Of Contents Menu Mode Programming Testing the SystemSystem Communication and Operation Features and Installation Highlights CapabilitiesFunctions Compatible DevicesImportant Installation Highlights Installer Please Read Mounting and Wiring the Control Cabinet and LockMounting the PC Board Alone no RF Receiver Mounting Board with RF Receiver Mounting the PC Board and RF ReceiverWiring to Keypads Supplementary Power optionalKeypad Addresses Size MA or less 100 mA 300 mA 500 mA 600 mAWiring the AC Transformer Backup BatteryWire Run Chart Distance from control Wire SizeAC Power Outlet Ground Earth GroundMetal Cold Water Pipe Hardwire Zones Wire Smoke DetectorsSmoke Detectors Normally Open Zones/ Normally Open Eolr ZonesInstalling the RF Receiver Installing a 5800TM ModuleRF Receiver No. of Zones Installing the Transmitters Installing a KeyswitchTransmitter Battery Life Connecting Relay Modules Keyswitch Wiring ConnectionsOn-Board Trigger Connector with 4-Wire Cable On-Board TriggersPhone Line/Phone Module Connections Phone Module Problems Long Range Radio ConnectionsAudio Alarm Verification Connections AAV, listen-In RJ31XTo enable keypads Programming OverviewAbout Programming KeypadsWireless Receiver, Transmitters, and Wireless Keys keyfobs Pager ProgrammingFunction Keys Output DevicesZone Type Definitions No Alarm Response KeyswitchConfigurable Monitor ZoneMenu Mode Programming ∗56, *57, ∗58, ∗79, ∗80, ∗81, ∗82 Loading Factory Defaults/Initializing for DownloadExiting the Programming Mode Task ProcedureReports as†† Enabled By… Table of Device AddressesSystem Setup Fields Data Field ProgrammingAbout Data Field Programming Programming Data FieldsZone Sounds & Timing Dialer Programming System Status Report Codes Cancel Report Code Alarm Restore Report CodeTrouble Restore Report Code Bypass Restore Report CodeMiscellaneous System Fields Event Log Enables Event Log Full Report CodeOption Selection No. of Reports In Armed Period per Zone Swinger SuppressionPager Programming Fields Configurable Zone Type Programming Fields Configurable Zone TypeConfigurable Zone Type Options Zone Type 90 Report CodesConfigurable Zone Type Charts Zone Conditions Represented EntriesKeypad Programming Fields Installation Instructions Menu Mode Programming Zone Programming ProcedureZone Programming Overview ∗56 and ∗58 Menu Modes SET to CONFIRM? 0 = no 1 = YESInput Type RF Trans Input S/N LInput S/N Xmit to Confirm∗58 Expert Programming Mode Procedures Completing Zone ProgrammingProgram ALPHA? 0 = no 1 = YES Wireless Key Programming Templates RC in LTemplate ? Wireless Key Predefined Default Templates Wireless Key TransmitterInput S/N AXXX-XXXX Xmit to Confirm Press to SkipOutput Device Programming Overview *79/*80 Menu Mode Menu Mode Output Device Mapping∗79 Menu Mode Output Device programming involvesMenu Mode Defining Output Functions ∗80 Menu ModeOutput Definition Components Prompt EntryE P Trig Zone List Overview ∗81 Menu Mode Menu ModeZone List Programming List No Used for…Function Key Programming Overview ∗57 Menu Mode Programming Function KeysPress the desired function key, A-D Is no longer available to be used as an endAbout Descriptor Programming Overview ∗82 Menu Mode Programming Zone Descriptors Menu mode ∗82When defining descriptors ZN 01 Back D OOR ZN 01 Back DoorZN 01 Back Door Custom?Character Ascii Chart For Adding Custom Words For Entering Zone DescriptorsProgramming Installer and User Schedules System Operation section= group number Installation Instructions System Communication and Operation System Communication OverviewReport Code Formats Where Code for Type +1/4+1 Report Standard ExpandedAdemco Contact ID Code DefinitionMaximum Setting the Real-Time Clock User Security CodesLevel User No Functions Keypad Commands Keypad FunctionsVoice Keypads Function DescriptionVarious System Trouble Displays Alpha DisplayMeaning Keys Displayed as ZoneTesting the System About Test ProceduresChecking Transmitter Enrollment Sniffer Mode System TestGo/No Go Test Mode Automatic Standby Battery TestsDialer Communication Test and Periodic Test Reports Automatic Periodic Test ReportSpecifications & Accessories Relay ModulePhone Modules Long Range RadioSeries Transmitter Input Loop Identification Compatible 5800 Series Transmitters TableModel Product Input Type Description 5827 Wireless Keypad Can be used to turn the burglary protection on and offInstallation Instructions Industrie Canada Federal Communications Commission FCC PartIndustry Canada FCC PartUL Notices SIA Quick Reference GuideLimitations and Warranty Limitations of this Alarm System10-2 Index 10-4 Summary of Connections Limited Warranty K0735V3 10/04 Rev. B