Honeywell Ademco Security Systems, VISTA-10P About Descriptor Programming Overview ∗82 Menu Mode

Page 47

About Descriptor Programming Overview (82 Menu Mode)

The system lets you assign zone descriptors for protection zones, keypad panics, and RF receiver supervision faults. Each description can be composed of a combination of words (up to 3) selected from a vocabulary of 196 words stored in memory (see a following page). In addition, up to 10 installer-defined words can be added to those already in memory. Thus, when an alarm or trouble occurs in a zone, an appropriate description for that zone's location can be displayed at the keypad. Zone descriptors are recommended for systems using Alpha display keypads, and are necessary if a Phone Module is used.

NOTE: You can enter zone descriptors when the zone is being defined in 56 Menu mode, but we recommend you do it using 82 Menu mode.

If using a 4285 or 4286VIP Phone Module, select from those words in the Alpha Vocabulary List shown in boldface type. The phone module will not provide annunciation of the other words.

If a 4285/4286 Phone Module is added to an existing system, the Alpha descriptors presently in the system should be reprogrammed, selecting from those words shown in boldface type in the Alpha Vocabulary List. The phone module will not provide annunciation of any other words.

Programming Zone Descriptors (Menu mode 82)

Descriptor programming involves:

1.Entering index numbers for up to three words from the vocabulary list for each descriptor;

2.Entering up to ten 10-digit custom words, if desired, which can then be used in descriptors.

When defining descriptors:

Pressing the [6] key accepts the entered index number and moves the cursor to the next position.

Pressing the [8] key saves the entered descriptor and moves to the next descriptor.

Start Zone Descriptor Programming mode by pressing *82 while in Data Programming mode.

 

PROMPT

 

 

 

VALID ENTRIES and EXPLANATION

 

 

 

 

 

 

Press 1 to program descriptors.

 

 

Program Alpha ?

 

 

 

 

 

 

0 = exit this mode

 

 

0=No, 1=Yes

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To program standard alpha descriptors from the fixed vocabulary, press 0. The system will

 

 

Cus tom W ords ?

 

 

 

 

then automatically display the descriptor for zone 1.

 

 

0=No, 1=Yes

00

 

 

 

 

 

To define custom words (described below in “Adding Custom Words” section), press 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary screen of zone 1 descriptor (if programmed) is displayed.

 

 

ZN 01

 

 

 

 

 

 

 

Press [∗] to start blinking cursor at zone number, then enter the zone number for which the

 

 

 

 

 

 

 

 

 

 

 

 

descriptor is being programmed.

 

 

 

 

 

 

 

If a descriptor is programmed for that zone, it is displayed.

To delete or change a previously programmed descriptor, press [∗] plus the same zone number. This will clear that descriptor and move the cursor to the first word position.

If you do not wish to change the existing descriptor, enter [∗] plus the next zone number

for which you wish to enter (or check) a descriptor. A summary display for that zone will appear. You must then press [∗] plus the same zone number again to program a descriptor for that zone.

If no descriptor has been programmed for that zone, the cursor moves to first word position.

ZN 01

Select first word of descriptor:

Press [#] plus the 3-digit index number for the first word from the Alpha Vocabulary List. See index for entries.

Example: The descriptor that we wish to enter for zone 1 is BACK DOOR. From the list, BACK = 013. Therefore, you would enter #013.

If you enter the wrong word, simply press [#] plus the 3-digit number for the desired word.

ZN 01 BACK

Save first word of descriptor:

6 = save word and go to next word in this descriptor

8 = save word and end descriptor if this is the only word used for the descriptor - go to summary screen

5-11

Image 47
Contents Ademco VISTA-10P Ademco VISTA-10PSIA Recommendations for Proper Protection Table Of Contents System Communication and Operation Menu Mode ProgrammingTesting the System Compatible Devices Features and Installation HighlightsCapabilities FunctionsImportant Installation Highlights Installer Please Read Mounting the PC Board Alone no RF Receiver Mounting and Wiring the ControlCabinet and Lock Mounting the PC Board and RF Receiver Mounting Board with RF ReceiverSize MA or less 100 mA 300 mA 500 mA 600 mA Wiring to KeypadsSupplementary Power optional Keypad AddressesDistance from control Wire Size Wiring the AC TransformerBackup Battery Wire Run ChartMetal Cold Water Pipe AC Power Outlet GroundEarth Ground Normally Open Zones/ Normally Open Eolr Zones Hardwire ZonesWire Smoke Detectors Smoke DetectorsRF Receiver No. of Zones Installing the RF ReceiverInstalling a 5800TM Module Transmitter Battery Life Installing the TransmittersInstalling a Keyswitch Keyswitch Wiring Connections Connecting Relay ModulesPhone Line/Phone Module Connections On-Board Trigger Connector with 4-Wire CableOn-Board Triggers Long Range Radio Connections Phone Module ProblemsRJ31X Audio Alarm Verification Connections AAV, listen-InKeypads To enable keypadsProgramming Overview About ProgrammingOutput Devices Wireless Receiver, Transmitters, and Wireless Keys keyfobsPager Programming Function KeysZone Type Definitions Monitor Zone No Alarm ResponseKeyswitch ConfigurableTask Procedure Menu Mode Programming ∗56, *57, ∗58, ∗79, ∗80, ∗81, ∗82Loading Factory Defaults/Initializing for Download Exiting the Programming ModeTable of Device Addresses Reports as†† Enabled By…Programming Data Fields System Setup FieldsData Field Programming About Data Field ProgrammingZone Sounds & Timing Dialer Programming System Status Report Codes Bypass Restore Report Code Cancel Report CodeAlarm Restore Report Code Trouble Restore Report CodeMiscellaneous System Fields No. of Reports In Armed Period per Zone Swinger Suppression Event Log EnablesEvent Log Full Report Code Option SelectionPager Programming Fields Zone Type 90 Report Codes Configurable Zone Type Programming FieldsConfigurable Zone Type Configurable Zone Type OptionsZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Installation Instructions SET to CONFIRM? 0 = no 1 = YES Menu Mode ProgrammingZone Programming Procedure Zone Programming Overview ∗56 and ∗58 Menu ModesXmit to Confirm Input Type RF TransInput S/N L Input S/NProgram ALPHA? 0 = no 1 = YES ∗58 Expert Programming Mode ProceduresCompleting Zone Programming Template ? Wireless Key Programming TemplatesRC in L Xmit to Confirm Press to Skip Wireless Key Predefined Default TemplatesWireless Key Transmitter Input S/N AXXX-XXXXOutput Device programming involves Output Device Programming Overview *79/*80 Menu ModeMenu Mode Output Device Mapping ∗79 Menu ModePrompt Entry Menu Mode Defining Output Functions∗80 Menu Mode Output Definition ComponentsE P Trig List No Used for… Zone List Overview ∗81 Menu ModeMenu Mode Zone List ProgrammingIs no longer available to be used as an end Function Key Programming Overview ∗57 Menu ModeProgramming Function Keys Press the desired function key, A-DWhen defining descriptors About Descriptor Programming Overview ∗82 Menu ModeProgramming Zone Descriptors Menu mode ∗82 Custom? ZN 01 Back D OORZN 01 Back Door ZN 01 Back DoorFor Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsSystem Operation section Programming Installer and User Schedules= group number Installation Instructions Report Code Formats System Communication and OperationSystem Communication Overview Code for Type +1/4+1 Report Standard Expanded WhereMaximum Ademco Contact IDCode Definition Level User No Functions Setting the Real-Time ClockUser Security Codes Function Description Keypad CommandsKeypad Functions Voice KeypadsKeys Displayed as Zone Various System Trouble DisplaysAlpha Display MeaningSystem Test Testing the SystemAbout Test Procedures Checking Transmitter Enrollment Sniffer ModeAutomatic Periodic Test Report Go/No Go Test ModeAutomatic Standby Battery Tests Dialer Communication Test and Periodic Test ReportsLong Range Radio Specifications & AccessoriesRelay Module Phone ModulesModel Product Input Type Description Series Transmitter Input Loop IdentificationCompatible 5800 Series Transmitters Table Can be used to turn the burglary protection on and off 5827 Wireless KeypadInstallation Instructions FCC Part Industrie CanadaFederal Communications Commission FCC Part Industry CanadaSIA Quick Reference Guide UL NoticesLimitations of this Alarm System Limitations and Warranty10-2 Index 10-4 Summary of Connections K0735V3 10/04 Rev. B Limited Warranty