Honeywell Ademco Security Systems, VISTA-10P Series Transmitter Input Loop Identification

Page 62

Installation Instructions

5800 Series Transmitter Input Loop Identification

All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input loops requires its own programming zone (e.g., a 5804's four inputs require four programming zones).

LOOP 3

LOOP 4

LOOP 3

LOOP 4

LOOP 2

YOU MUST

 

ENROLL

LOOP 2

THIS

LOOP 1

BUTTON

 

YOU MUST

ON

OFF

LOOP 2

 

 

LOOP

ENROLL

 

 

 

THIS

 

 

LOOP 1

1

 

 

BUTTON

 

 

 

 

 

 

 

LOOP 3

LOOP 4 YOU MUST ENROLL THIS BUTTON

LOOP 1

SET

5801

ENROLL AS

"UR" OR "RF"

LOOP 1

5802MN

 

ENROLL AS

5804

"UR" OR "RF"

ENROLL AS "BR"

HOUSE

CODE

5804BD

ENROLL AS "BR"

LOOP 1 (PRIMARY)

5808

ENROLL AS "RF"

LOOP 1

5809

ENROLL AS "RF"

LOOP 2 (REED)

LOOP 2

 

LOOP 2

LOOP 2

 

(AUX.

(REED)

 

(REED)

CENTER)

LOOP 1

 

LOOP 1

LOOP 3

(TERMINALS)

ALTERNATE

(TERMINALS)

(AUX.

 

POSITION

 

 

 

RIGHT)

 

FOR LOOP 2

 

 

 

 

5816

5816MN

 

5817

ENROLL AS "RF"

ENROLL AS "RF"

 

ENROLL AS "RF"

 

 

 

LOOP 2

 

 

 

(REED)

 

 

 

NOTE: For information on any transmitter not shown, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc.

UL NOTE: The following transmitters are not intended for use in UL installations:

5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, and 5850.

 

 

 

LOOP 3

 

 

 

LOOP

 

 

(TERMINALS)

LOOP 1

 

 

1

 

 

 

 

(INTERNAL

 

 

MOTION

 

LOOP 1

 

 

SHOCK

 

 

 

 

 

 

SENSOR

(Green)

 

 

LOOP 3

(TERMINALS)

 

(Red)

 

 

 

 

(Yellow)

 

 

(TERMINALS)

 

 

 

 

 

 

 

 

5819

 

5819S (WHS & BRS)

5850 (GBD)

5890

 

 

 

ENROLL AS

 

 

ENROLL AS "RF"

 

 

ENROLL AS "RF"

ENROLL AS "RF"

"RF" OR "RM"

V20P-006-V0

Compatible 5800 Series Transmitters Table

Model

Product

Input Type

Description

5801

Wireless Panic

UR or RF

Four pushbuttons, each with a unique input (loop) code.

 

Transmitter

 

Programmable responses (e.g., Panic, Arm, Disarm, etc.)

 

 

 

 

5802

Pendant (Personal

BR Only

Has single pushbutton.

 

Emergency Transmitter)

 

Usually programmed for response type of 24-Hr audible or 24-Hr

 

 

 

Silent (other zone responses are possible).

5802CP

Belt Clip (Personal

BR Only

Same as 5802.

 

Emergency)

 

 

 

 

 

 

5802MN

Miniature (Personal

UR or RF

Same as 5802.

 

Emergency Trans.)

 

 

 

 

 

 

5804

Wireless Key

BR Only

Has four pushbuttons, each with a unique input (loop) code.

 

Transmitter

 

Programmable responses (e.g., Arm, Disarm, etc.)

 

 

 

 

5804BD

Bi-Directional

BR

House ID must be set.

 

Wireless Key

 

Requires 5800TM Transmitter Module.

 

 

 

Can indicate system status via its 2 LEDs and built-in sounder.

 

 

 

Has four pushbuttons, each with a unique input (loop) code.

 

 

 

Operates the system similarly to wired keypads.

5806

Wireless

RF

One-piece smoke detectors with a built-in transmitter.

5807

Photoelectric Smoke

 

 

5808

Detectors

 

 

 

 

 

 

5809

Heat Detector

RF

One-piece rate-of-rise heat detector with a built-in transmitter.

 

 

 

 

5816

Door/Window

RF

Has two unique input (loop) codes: one for a wired closed circuit

5816MN

Transmitters

 

contact loop; the other for its built-in reed switch (used with a

 

 

magnet).

 

 

 

5816TEMP

Low-Temp. Sensor

RF

Transmits a fault condition when temperature drops below 45°F.

 

 

 

 

8-2

Image 62
Contents Ademco VISTA-10P Ademco VISTA-10PSIA Recommendations for Proper Protection Table Of Contents System Communication and Operation Menu Mode ProgrammingTesting the System Functions Features and Installation HighlightsCapabilities Compatible DevicesImportant Installation Highlights Installer Please Read Mounting the PC Board Alone no RF Receiver Mounting and Wiring the ControlCabinet and Lock Mounting Board with RF Receiver Mounting the PC Board and RF ReceiverKeypad Addresses Wiring to KeypadsSupplementary Power optional Size MA or less 100 mA 300 mA 500 mA 600 mAWire Run Chart Wiring the AC TransformerBackup Battery Distance from control Wire SizeMetal Cold Water Pipe AC Power Outlet GroundEarth Ground Smoke Detectors Hardwire ZonesWire Smoke Detectors Normally Open Zones/ Normally Open Eolr ZonesRF Receiver No. of Zones Installing the RF ReceiverInstalling a 5800TM Module Transmitter Battery Life Installing the TransmittersInstalling a Keyswitch Connecting Relay Modules Keyswitch Wiring ConnectionsPhone Line/Phone Module Connections On-Board Trigger Connector with 4-Wire CableOn-Board Triggers Phone Module Problems Long Range Radio ConnectionsAudio Alarm Verification Connections AAV, listen-In RJ31XAbout Programming To enable keypadsProgramming Overview KeypadsFunction Keys Wireless Receiver, Transmitters, and Wireless Keys keyfobsPager Programming Output DevicesZone Type Definitions Configurable No Alarm ResponseKeyswitch Monitor ZoneExiting the Programming Mode Menu Mode Programming ∗56, *57, ∗58, ∗79, ∗80, ∗81, ∗82Loading Factory Defaults/Initializing for Download Task ProcedureReports as†† Enabled By… Table of Device AddressesAbout Data Field Programming System Setup FieldsData Field Programming Programming Data FieldsZone Sounds & Timing Dialer Programming System Status Report Codes Trouble Restore Report Code Cancel Report CodeAlarm Restore Report Code Bypass Restore Report CodeMiscellaneous System Fields Option Selection Event Log EnablesEvent Log Full Report Code No. of Reports In Armed Period per Zone Swinger SuppressionPager Programming Fields Configurable Zone Type Options Configurable Zone Type Programming FieldsConfigurable Zone Type Zone Type 90 Report CodesConfigurable Zone Type Charts Zone Conditions Represented EntriesKeypad Programming Fields Installation Instructions Zone Programming Overview ∗56 and ∗58 Menu Modes Menu Mode ProgrammingZone Programming Procedure SET to CONFIRM? 0 = no 1 = YESInput S/N Input Type RF TransInput S/N L Xmit to ConfirmProgram ALPHA? 0 = no 1 = YES ∗58 Expert Programming Mode ProceduresCompleting Zone Programming Template ? Wireless Key Programming TemplatesRC in L Input S/N AXXX-XXXX Wireless Key Predefined Default TemplatesWireless Key Transmitter Xmit to Confirm Press to Skip∗79 Menu Mode Output Device Programming Overview *79/*80 Menu ModeMenu Mode Output Device Mapping Output Device programming involvesOutput Definition Components Menu Mode Defining Output Functions∗80 Menu Mode Prompt EntryE P Trig Zone List Programming Zone List Overview ∗81 Menu ModeMenu Mode List No Used for…Press the desired function key, A-D Function Key Programming Overview ∗57 Menu ModeProgramming Function Keys Is no longer available to be used as an endWhen defining descriptors About Descriptor Programming Overview ∗82 Menu ModeProgramming Zone Descriptors Menu mode ∗82 ZN 01 Back Door ZN 01 Back D OORZN 01 Back Door Custom?Character Ascii Chart For Adding Custom Words For Entering Zone DescriptorsProgramming Installer and User Schedules System Operation section= group number Installation Instructions Report Code Formats System Communication and OperationSystem Communication Overview Where Code for Type +1/4+1 Report Standard ExpandedMaximum Ademco Contact IDCode Definition Level User No Functions Setting the Real-Time ClockUser Security Codes Voice Keypads Keypad CommandsKeypad Functions Function DescriptionMeaning Various System Trouble DisplaysAlpha Display Keys Displayed as ZoneChecking Transmitter Enrollment Sniffer Mode Testing the SystemAbout Test Procedures System TestDialer Communication Test and Periodic Test Reports Go/No Go Test ModeAutomatic Standby Battery Tests Automatic Periodic Test ReportPhone Modules Specifications & AccessoriesRelay Module Long Range RadioModel Product Input Type Description Series Transmitter Input Loop IdentificationCompatible 5800 Series Transmitters Table 5827 Wireless Keypad Can be used to turn the burglary protection on and offInstallation Instructions Industry Canada Industrie CanadaFederal Communications Commission FCC Part FCC PartUL Notices SIA Quick Reference GuideLimitations and Warranty Limitations of this Alarm System10-2 Index 10-4 Summary of Connections Limited Warranty K0735V3 10/04 Rev. B