Linear DVS-2400 manual Basic Console Programming, Start In Test, MASTER USER CODE 1 GONG & 5 BEEPS

Page 14
6.BASIC CONSOLE PROGRAMMING

6.BASIC CONSOLE PROGRAMMING

In a new installation, when power is first applied the system's master user code is “1234”.

CREATE THE MASTER USER CODE

NOTE: Local programming must be entered on the Console's keypad, not on a wireless remote keypad.

1.PressCREATE THE MASTER USER CODE(clears keypad if any other keys have been pressed).

2.Place the Console in Test Mode (enter 1234 and press TEST.

A “gong” and four “beeps” will sound.

3.Enter the Setup Mode from Test Mode, enter 1234 then press TEST again.

A “gong” and fi ve “beeps” will sound. The system is now in Test Mode.

4.Enter 99 then press HOME.

5.Enter any combination of 1-5 digits for the master user code, then press AWAY.

NOTE: For maximum security, a three to five digit code is recommended.

6.Press and hold the OFF key for 3 seconds to exit program mode.

7.Test the new master user code by entering it then pressing TEST.

8.Log the master user code in the box below.

MASTER USER CODE:

NOTE: The master user code can be used to enter Setup Mode. The restricted user codes cannot. To create restricted user codes, see the “Advanced Programming” section of this manual.

PROGRAM THE SENSORS INTO THE CONSOLE’S MEMORY

ENTERING

SETUP

MODE

START IN OFF

CLEARS

KEYPAD

DEFAULT

MASTER

USER

CODE

1 GONG &

4 BEEPS (TEST MODE)

DEFAULT

MASTER

USER

CODE

1 GONG &

5 BEEPS (SETUP MODE)

SETTING A

NEW MASTER

USER CODE

START IN SETUP

PROGRAMMING

STEP #99

PROGRAM

NEW

MASTER

USER

CODE

STORE

CODE

HOLD FOR

3 SECONDS TO EXIT SETUP

DONE

Each wireless sensor that is going to be used with the Console must be programmed into the Console’s memory.

START IN TEST

1.

Start with the Console in Test Mode (enter any user

 

code and press TEST).

2.

Enter the Setup Mode from Test Mode, enter the

 

master user code then press TEST again.

 

A “Gong” and fi ve “Beeps” will sound.

 

The sensor status indicators will light for any sensors

 

programmed into the Console.

3.

Enter an unused sensor number from 01-24 (you

 

must enter two digits, example: 5 = 05).

 

The sensor indicator light will fl ash for the sensor number

 

selected.

4.

Activate the sensor by sending a test or alarm

 

signal (be sure the sensor's battery is connected or

 

that its battery protection strip is removed).

 

A single “Bing” tone will sound and the sensor status

TEST

MASTER USER CODE

1 GONG &

5 BEEPS

NEW SENSOR NUMBER

indicator for that sensor will stay lit.

5. Enter another sensor number or exit Setup Mode by

pressing the OFF key for three seconds.

ACTIVATE SENSOR

DONE

12

Image 14
Contents SECURITY SUPERVISED WIRELESS SECURITY CONSOLEInstallation & Programming Instructions USA & CanadaThis symbol is for important notes INTRODUCTIONTABLE OF CONTENTS 1.THE DVS-2400SECURITY SYSTEM CONSOLEDOOR/WINDOW SENSORS WIRELESS KEYPADREMOTE CONTROLS SMOKE DETECTOREXAMPLE SYSTEM DESIGN THE INSTALLATION2.SECURITY SYSTEM FLOOR PLAN Example Residential Security System Floor PlanABOUT SENSOR STATUS SUPERVISION 3.TYPICAL SYSTEM SENSORSDOOR/WINDOW SENSOR WIRELESS KEYPADSwitching to Off Mode stops the alarm siren 4.CONSOLE FEATURES5 4 3 Switching to Chime Mode stops the alarm sirenType 2AG, 1-ampfuse CASE LOCKING SCREW 5.CONSOLE INSTALLATIONCONSOLE LOCATION WALL MOUNTINGcan talk to the occupants through the external EXTERNAL CONSOLE SPEAKER CONNECTIONEXTERNAL ALARM SIREN CONNECTION Connect the Console to the telephone line if the TELEPHONE LINE CONNECTIONAUTOMATION OUTPUT CONNECTION OPTIONAL BACKUP BATTERY INSTALLATION OPTIONAL CONSOLE POWER CONNECTIONnot plug the transformer in until the wiring is completeSTART IN TEST indicator for that sensor will stay lit6.BASIC CONSOLE PROGRAMMING MASTER USER CODE 1 GONG & 5 BEEPSselect a sensor number to program the sensor into PROGRAMMING DIFFERENT SENSOR TYPESFollow the instructions on the previous page to For DXT-61, DXT-21, DXS-21, DXT-41,& DXS-62A7.BASIC SENSOR INSTALLATION DXS-10WIRELESS KEYPAD4.Snap sensor onto mounting plate DXS-31& DXS-32DOOR/WINDOW SENSORSTEST SENSORS 8.CUSTOMIZING THE CONSOLE LABELING THE SENSORS9.CONSOLE OPERATING MODES and stops any alarms in progresscaused the alarm will fl ash OFF MODESTART IN OFF OR CHIME MODE HOME MODESECURE EXIT START IN HOME MODEOPTIONAL YOUR USER CODE 1 GONG & 3 BEEPS AWAY MODEQUICK ARM START HERE HOLDTEST MODE 3 beeps being the strongest signalstatus indicators START IN OFFSENSOR LOW BATTERIES CONSOLE LOW BATTERY10.SYSTEM TROUBLE INDICATIONS SENSOR RADIO TROUBLEACTIVATE SENSOR DONE START IN TEST and the sensor status indicator will turn off11.CUSTOMIZING THE SYSTEM MASTER USER CODE 1 GONG & 5 BEEPS SENSORSENSOR NUMBER FOR INTERIOR SENSOR NUMBER FOR CHIME8 FOR 8 TUV CHIME ZONE AWAY 1 BING DONE 7 FOR 7 PRS INTERIOR ZONE AWAY 1 BING DONEMAKING A SENSOR PERFORM A DIFFERENT FUNCTION SENSOR NUMBER FOR FUNCTION CHANGENEW FUNCTION NUMBER FOR SENSOR AWAY 1 BING DONE AWAYHOME = PROGRAM SETUP MODE12.ADVANCED PROGRAMMING TEST = REMOVEENTRY DELAY TIME CHANGING A SENSORS RESTORE REQUIREMENTSCHANGING A SENSORS SUPERVISION EXIT DELAY TIMEFIRE SIREN TIME REMOTE CONTROL ARMING LEVELREMOTE CONTROL DISARMING LEVEL AUTOMATION OUTPUT TIMEDISABLING QUICK ARMING SILENT BURGLARY ALARMSSILENT EMERGENCY ALARMS AUTOMATIC RESTORAL OF BYPASSED SENSORSAUTOMATION OUTPUT ON DURING AND AFTER ALARM AUTOMATION OUTPUT MODE DURING ALARMREMOTE CONTROL ARM/DISARM CHIRP AUTOMATION OUTPUT ON DURING ALARMAUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS REMOTE ACCESS PASSWORDAUTOMATION OUTPUT WHILE ARMED AUTOMATION OUTPUT POLARITYchanged using programming STEP #99 Because access to programming would be impossibleusing these steps. The master user code can be CONSOLE MASTER RESETGeneral Communicator Programming Table SETUP MODE13.COMMUNICATOR PROGRAMMING SETUP MODE2-WAYAUDIO COMMUNICATOR ENABLEGENERAL COMMUNICATOR OPTIONS VOICE RESPONSEDIALING METHOD CALL LIMITERDIALING DELAY 0PROGRAMMING STEP #101CALL ROUTING COMMUNICATOR REPORTING OPTIONSREPORTING FORMAT Communicator Reporting Option TableSECONDARY TELEPHONE NUMBER ACCOUNT NUMBERPRIMARY TELEPHONE NUMBER SUPERVISORY OR PAGER TELEPHONE NUMBEROPENING AND CLOSING REPORTS REPORT CONSOLE TROUBLEREPORT FORCE ARMING POINT ID REPORTINGSTEPS #201-206 COMMUNICATOR REPORTING CODESGENERAL REPORTING CODES General Reporting Codes TableFORCE ARMING REPORTING CODE SYSTEM REPORTING CODESSTEPS #261-266 DURESS REPORTING CODESTEPS #210-233 4 BY 2 FORMAT POINT ID ALARM REPORT CODES4 BY 2 FORMAT POINT ID REPORTING CODES 4 BY 2 FORMAT POINT ID TROUBLE REPORT CODESSTEP # 4 by 2 Format Point ID Reporting Code Table4 BY 2 FORMAT POINT ID REPORTING CODES PROGRAMMING FUNCTION14. IMPORTANT INFORMATION LINEAR LIMITED WARRANTYWIRELESS PRODUCT NOTICE FCC NOTICE
Related manuals
Manual 48 pages 58.1 Kb

DVS-2400 specifications

The Linear DVS-1200, DVS-2400, RA-2400, DUAL-824, and DVS-2408 are advanced digital video surveillance systems designed for a variety of security applications. These models offer state-of-the-art features, technologies, and characteristics that enhance security monitoring and recording capabilities.

The DVS-1200 is a compact and efficient digital video recorder that supports up to 12 channels of video input. It features high-resolution recording capabilities, providing clear and detailed images. With real-time playback and advanced motion detection, the DVS-1200 allows users to monitor activities effectively. Its user-friendly interface simplifies configuration and operation, making it accessible for both novice and experienced users.

Upgraded for larger installations, the DVS-2400 supports up to 24 channels. This model is equipped with H.264 video compression technology, significantly reducing storage requirements while maintaining high-quality images. The DVS-2400 also offers remote access capabilities, enabling users to view live footage or playback recorded events from anywhere using a smartphone or computer. Its built-in analytics features allow for motion detection, line crossing alerts, and more, enhancing overall security.

The RA-2400 is a remarkable model designed for robust performance in demanding environments. This recorder not only supports 24 channels but also integrates advanced RAID technology for data redundancy and enhanced storage reliability. The RA-2400 is ideal for applications where data loss is unacceptable, making it suitable for critical infrastructure and high-security locations.

The DUAL-824 model stands out with its unique dual-stream encoding feature. It allows simultaneous recording and streaming of two video resolutions, providing flexibility for different applications such as local monitoring and remote access. This model supports up to 8 channels and is equipped with advanced event triggers, ensuring significant activities do not go unnoticed.

Finally, the DVS-2408 is a versatile and high-performance system designed for larger facilities. With support for 24 channels and the ability to integrate with various IP cameras, the DVS-2408 delivers exceptional scalability. This model comes with comprehensive software for monitoring and management, allowing for multiple users and custom user permissions.

Together, these Linear video surveillance models represent a robust and reliable solution for modern security needs, featuring the latest technologies and high-quality performance to ensure safety and peace of mind in various environments.