Linear DVS-2400 manual Console Features, 5 4 3, Switching to Off Mode stops the alarm siren

Page 8
4.CONSOLE FEATURES

4.CONSOLE FEATURES

5

4

3

2

6

7

1

8

124-HOUR BUTTONS

Pressing FIRE for two seconds sounds the fi re siren and sends a “fi re” message to a central monitoring station through the digital communicator (if the system is monitored).

Pressing EMERGENCY for two seconds sounds the emergency siren and sends an “emergency” message to a central monitoring station through the digital communicator (if the system is monitored).

Both work even when system is disarmed.

IMPORTANT: For personal emergency use only. Not for use as a UL Listed Medical Alert System.

2MODE BUTTONS

Used to operate the system.

OFF

Off Mode disarms the system.

Switching to Off Mode stops the alarm siren.

Multiple Beeps sound and sensor status indicators fl ash if an alarm has occurred.

Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.

CHIME

Chime Mode disarms the system.

Switching to Chime Mode stops the alarm siren.

Multiple Beeps sound and sensor status indicators fl ash if an alarm has occurred.

Multiple Beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.

Chime Mode is for monitoring doors and windows.

Use this mode as an “automatic door chime” when at home.

Opening any protected door or window causes the Console to “ding-dong”.

HOME

Home Mode arms the perimeter sensors, but not the interior sensors.

Use this mode when anyone is staying behind.

Interior motion detectors and interior door sensors are not armed.

Home secure mode makes all delayed perimeter sensors instant.

Secure exit mode starts an exit delay while remaining in Home Mode.

Re-entering during the exit delay restarts the exit delay (one time only).

AWAY

Away Mode arms the entire system.

Use this mode when leaving home.

Door sensors set for delayed will have a time delay that allows the user to leave and enter the premises without sounding the alarm.

Re-entering during the exit delay restarts the exit delay (one time only).

Entry Delay Beeps warn the user to disarm the system before the siren starts.

TEST

Test Mode is for testing the system sensors.

All sensor status lights blink when the Test Mode is entered.

Each sensor status light will stop blinking when its sensor is tested.

Hold the TEST button down to test all of the Console's indicator lights.

3MODE INDICATORS

Specifi c indicator will light showing the mode the Console is in.

HOME indicator will blink during Secure Exit and Home Instant modes.

AWAY indicator will blink during the exit delay in the Away Mode.

4CONSOLE STATUS INDICATORS

Shows the current status of the Console.

POWER LIGHT

Glows when AC power is on.

Blinks when AC power is off and backup battery is installed.

Blinks when the backup battery is low, recharging or missing.

Off when AC power is off and no backup battery is installed (system disabled).

BATTERIES LIGHT

Blinks when one or more sensors have a low battery.

Press5 for one second to view sensor status. Sensor status indicator for any sensor with a low battery will light along with the BATTERIES indicator. Any trouble indications will follow during the fi ve second status cycle.

Switch to Test Mode after replacing the sensor battery and completely test the system (see Test Mode). Switching to Test Mode clears the low battery indication.

TROUBLE LIGHT

Blinks when one or more sensors have not reported status during the eight hour status time period.

Press★Switching to Off Mode stops the alarm siren. for one second to view sensor status. Sensor status indicator for any sensor that has not reported in will light along with the TROUBLE indicator. Any low battery indications will follow during the fi ve second status cycle.

Switch to Test Mode after servicing the sensor and completely test the system (see Test Mode). Switching to Test Mode clears the trouble indication.

5SIREN SPEAKER

Makes unique sounds for burglary, fi re and emergencies.

Alarm sirens stop automatically after fi ve minutes.

Sounds advisory tones to confi rm keystrokes from the Console.

Sounds mode selection tones.

Sounds alarm memory tones.

Beeps when Automation Output is activated.

Speaks the system status information when optional VB-2 digital voice synthesis module is installed.

Terminals available for an external siren.

6STATUS INDICATORS

Indicates the status of each of the system’s sensors.

Lights show which doors and windows are open.

Lights fl ash to display sensors that have caused an alarm.

Stick-on labels are provided to identify the custom sensor locations.

7CASE ACCESS SCREW (HIDDEN)

Remove clear display window and sensor identifi cation card to gain access to the screw.

Remove case access screw to unlock case. Case hinges open to the left.

8KEYPAD

Backlit keys for easy viewing in low light conditions.

For entering the user's user code (numerically or alphabetically).

Used when programming system options.

Press ★Switching to Chime Mode stops the alarm siren. to activate the Automation Output.

PressManual background to clear keypad if the wrong key is pressed.

PressManual background for one second to view sensor battery and supervisory status (see BATTERIES and TROUBLE indicator description).

6

Image 8
Contents SUPERVISED WIRELESS SECURITY CONSOLE Installation & Programming InstructionsSECURITY USA & CanadaThis symbol is for important notes INTRODUCTIONTABLE OF CONTENTS 1.THE DVS-2400SECURITY SYSTEM CONSOLEWIRELESS KEYPAD REMOTE CONTROLSDOOR/WINDOW SENSORS SMOKE DETECTORDESIGN THE INSTALLATION 2.SECURITY SYSTEM FLOOR PLANEXAMPLE SYSTEM Example Residential Security System Floor Plan3.TYPICAL SYSTEM SENSORS DOOR/WINDOW SENSORABOUT SENSOR STATUS SUPERVISION WIRELESS KEYPAD4.CONSOLE FEATURES 5 4 3Switching to Off Mode stops the alarm siren Switching to Chime Mode stops the alarm sirenType 2AG, 1-ampfuse 5.CONSOLE INSTALLATION CONSOLE LOCATIONCASE LOCKING SCREW WALL MOUNTINGcan talk to the occupants through the external EXTERNAL CONSOLE SPEAKER CONNECTIONEXTERNAL ALARM SIREN CONNECTION Connect the Console to the telephone line if the TELEPHONE LINE CONNECTIONAUTOMATION OUTPUT CONNECTION OPTIONAL CONSOLE POWER CONNECTION not plug the transformer in until the wiring isBACKUP BATTERY INSTALLATION OPTIONAL completeindicator for that sensor will stay lit 6.BASIC CONSOLE PROGRAMMINGSTART IN TEST MASTER USER CODE 1 GONG & 5 BEEPSPROGRAMMING DIFFERENT SENSOR TYPES Follow the instructions on the previous page toselect a sensor number to program the sensor into For DXT-61, DXT-21, DXS-21, DXT-41,& DXS-62A7.BASIC SENSOR INSTALLATION DXS-10WIRELESS KEYPAD4.Snap sensor onto mounting plate DXS-31& DXS-32DOOR/WINDOW SENSORSTEST SENSORS 8.CUSTOMIZING THE CONSOLE LABELING THE SENSORSand stops any alarms in progress caused the alarm will fl ash9.CONSOLE OPERATING MODES OFF MODEHOME MODE SECURE EXITSTART IN OFF OR CHIME MODE START IN HOME MODEAWAY MODE QUICK ARMOPTIONAL YOUR USER CODE 1 GONG & 3 BEEPS START HERE HOLD3 beeps being the strongest signal status indicatorsTEST MODE START IN OFFCONSOLE LOW BATTERY 10.SYSTEM TROUBLE INDICATIONSSENSOR LOW BATTERIES SENSOR RADIO TROUBLEand the sensor status indicator will turn off 11.CUSTOMIZING THE SYSTEMACTIVATE SENSOR DONE START IN TEST MASTER USER CODE 1 GONG & 5 BEEPS SENSORSENSOR NUMBER FOR CHIME 8 FOR 8 TUV CHIME ZONE AWAY 1 BING DONESENSOR NUMBER FOR INTERIOR 7 FOR 7 PRS INTERIOR ZONE AWAY 1 BING DONESENSOR NUMBER FOR FUNCTION CHANGE NEW FUNCTION NUMBER FOR SENSOR AWAY 1 BING DONEMAKING A SENSOR PERFORM A DIFFERENT FUNCTION AWAYSETUP MODE 12.ADVANCED PROGRAMMINGHOME = PROGRAM TEST = REMOVECHANGING A SENSORS RESTORE REQUIREMENTS CHANGING A SENSORS SUPERVISIONENTRY DELAY TIME EXIT DELAY TIMEREMOTE CONTROL ARMING LEVEL REMOTE CONTROL DISARMING LEVELFIRE SIREN TIME AUTOMATION OUTPUT TIMESILENT BURGLARY ALARMS SILENT EMERGENCY ALARMSDISABLING QUICK ARMING AUTOMATIC RESTORAL OF BYPASSED SENSORSAUTOMATION OUTPUT MODE DURING ALARM REMOTE CONTROL ARM/DISARM CHIRPAUTOMATION OUTPUT ON DURING AND AFTER ALARM AUTOMATION OUTPUT ON DURING ALARMREMOTE ACCESS PASSWORD AUTOMATION OUTPUT WHILE ARMEDAUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS AUTOMATION OUTPUT POLARITYBecause access to programming would be impossible using these steps. The master user code can bechanged using programming STEP #99 CONSOLE MASTER RESETSETUP MODE 13.COMMUNICATOR PROGRAMMINGGeneral Communicator Programming Table SETUP MODECOMMUNICATOR ENABLE GENERAL COMMUNICATOR OPTIONS2-WAYAUDIO VOICE RESPONSECALL LIMITER DIALING DELAYDIALING METHOD 0PROGRAMMING STEP #101COMMUNICATOR REPORTING OPTIONS REPORTING FORMATCALL ROUTING Communicator Reporting Option TableACCOUNT NUMBER PRIMARY TELEPHONE NUMBERSECONDARY TELEPHONE NUMBER SUPERVISORY OR PAGER TELEPHONE NUMBERREPORT CONSOLE TROUBLE REPORT FORCE ARMINGOPENING AND CLOSING REPORTS POINT ID REPORTINGCOMMUNICATOR REPORTING CODES GENERAL REPORTING CODESSTEPS #201-206 General Reporting Codes TableSYSTEM REPORTING CODES STEPS #261-266FORCE ARMING REPORTING CODE DURESS REPORTING CODE4 BY 2 FORMAT POINT ID ALARM REPORT CODES 4 BY 2 FORMAT POINT ID REPORTING CODESSTEPS #210-233 4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES4 by 2 Format Point ID Reporting Code Table 4 BY 2 FORMAT POINT ID REPORTING CODESSTEP # PROGRAMMING FUNCTIONLINEAR LIMITED WARRANTY WIRELESS PRODUCT NOTICE14. IMPORTANT INFORMATION FCC NOTICE
Related manuals
Manual 48 pages 58.1 Kb

DVS-2400 specifications

The Linear DVS-1200, DVS-2400, RA-2400, DUAL-824, and DVS-2408 are advanced digital video surveillance systems designed for a variety of security applications. These models offer state-of-the-art features, technologies, and characteristics that enhance security monitoring and recording capabilities.

The DVS-1200 is a compact and efficient digital video recorder that supports up to 12 channels of video input. It features high-resolution recording capabilities, providing clear and detailed images. With real-time playback and advanced motion detection, the DVS-1200 allows users to monitor activities effectively. Its user-friendly interface simplifies configuration and operation, making it accessible for both novice and experienced users.

Upgraded for larger installations, the DVS-2400 supports up to 24 channels. This model is equipped with H.264 video compression technology, significantly reducing storage requirements while maintaining high-quality images. The DVS-2400 also offers remote access capabilities, enabling users to view live footage or playback recorded events from anywhere using a smartphone or computer. Its built-in analytics features allow for motion detection, line crossing alerts, and more, enhancing overall security.

The RA-2400 is a remarkable model designed for robust performance in demanding environments. This recorder not only supports 24 channels but also integrates advanced RAID technology for data redundancy and enhanced storage reliability. The RA-2400 is ideal for applications where data loss is unacceptable, making it suitable for critical infrastructure and high-security locations.

The DUAL-824 model stands out with its unique dual-stream encoding feature. It allows simultaneous recording and streaming of two video resolutions, providing flexibility for different applications such as local monitoring and remote access. This model supports up to 8 channels and is equipped with advanced event triggers, ensuring significant activities do not go unnoticed.

Finally, the DVS-2408 is a versatile and high-performance system designed for larger facilities. With support for 24 channels and the ability to integrate with various IP cameras, the DVS-2408 delivers exceptional scalability. This model comes with comprehensive software for monitoring and management, allowing for multiple users and custom user permissions.

Together, these Linear video surveillance models represent a robust and reliable solution for modern security needs, featuring the latest technologies and high-quality performance to ensure safety and peace of mind in various environments.