Linear DVS-2400 manual Customizing The Console, Labeling The Sensors

Page 18
8.CUSTOMIZING THE CONSOLE

8.CUSTOMIZING THE CONSOLE

The Console can be customized for the specifi c installation.

A label sheet with sensor location names is provided with the Console.

Labeling the sensors allows quick and easy identifi cation of where a door or window is open, where any alarms have occurred, where a sensor with a low battery is, or where a sensor with trouble is.

LABELING THE SENSORS

1.Use a paper clip to remove the clear display window.

2.Bend down the tabs on the sensor number card and fi t it onto the Console.

3.Open one protected door/window to light its sensor status light on the Console.

4.Choose a label that describes the sensor location, or write the location on a blank label, and stick it in the area to the right of the sensor light.

5.Close the protected opening that you just labeled.

6.Repeat for each protected opening.

7.Stick the WIRELESS KEYPAD label in the sensor number location for the wireless keypad (if used).

8.Replace the clear display window when fi nished.

USE SENSOR

LABELS PROVIDED

WRITE IN SPECIAL

LOCATIONS ON

BLANK LABELS

BEND TABS DOWN

AND INSERT IN

SLOTS

OPEN DOOR

OR WINDOW

TO LIGHT

SENSOR STATUS

INDICATOR

ON CONSOLE

APPLY SENSOR IDENTIFICATION

LABELS TO THE APPROPRIATE

SENSOR LOCATIONS

16

Image 18
Contents SECURITY SUPERVISED WIRELESS SECURITY CONSOLEInstallation & Programming Instructions USA & CanadaThis symbol is for important notes INTRODUCTIONTABLE OF CONTENTS 1.THE DVS-2400SECURITY SYSTEM CONSOLEDOOR/WINDOW SENSORS WIRELESS KEYPADREMOTE CONTROLS SMOKE DETECTOREXAMPLE SYSTEM DESIGN THE INSTALLATION2.SECURITY SYSTEM FLOOR PLAN Example Residential Security System Floor PlanABOUT SENSOR STATUS SUPERVISION 3.TYPICAL SYSTEM SENSORSDOOR/WINDOW SENSOR WIRELESS KEYPADSwitching to Off Mode stops the alarm siren 4.CONSOLE FEATURES5 4 3 Switching to Chime Mode stops the alarm sirenType 2AG, 1-ampfuse CASE LOCKING SCREW 5.CONSOLE INSTALLATIONCONSOLE LOCATION WALL MOUNTINGEXTERNAL CONSOLE SPEAKER CONNECTION EXTERNAL ALARM SIREN CONNECTIONcan talk to the occupants through the external TELEPHONE LINE CONNECTION AUTOMATION OUTPUT CONNECTION OPTIONALConnect the Console to the telephone line if the BACKUP BATTERY INSTALLATION OPTIONAL CONSOLE POWER CONNECTIONnot plug the transformer in until the wiring is completeSTART IN TEST indicator for that sensor will stay lit6.BASIC CONSOLE PROGRAMMING MASTER USER CODE 1 GONG & 5 BEEPSselect a sensor number to program the sensor into PROGRAMMING DIFFERENT SENSOR TYPESFollow the instructions on the previous page to For DXT-61, DXT-21, DXS-21, DXT-41,& DXS-62A7.BASIC SENSOR INSTALLATION DXS-10WIRELESS KEYPADDXS-31& DXS-32DOOR/WINDOW SENSORS TEST SENSORS4.Snap sensor onto mounting plate 8.CUSTOMIZING THE CONSOLE LABELING THE SENSORS9.CONSOLE OPERATING MODES and stops any alarms in progresscaused the alarm will fl ash OFF MODESTART IN OFF OR CHIME MODE HOME MODESECURE EXIT START IN HOME MODEOPTIONAL YOUR USER CODE 1 GONG & 3 BEEPS AWAY MODEQUICK ARM START HERE HOLDTEST MODE 3 beeps being the strongest signalstatus indicators START IN OFFSENSOR LOW BATTERIES CONSOLE LOW BATTERY10.SYSTEM TROUBLE INDICATIONS SENSOR RADIO TROUBLEACTIVATE SENSOR DONE START IN TEST and the sensor status indicator will turn off11.CUSTOMIZING THE SYSTEM MASTER USER CODE 1 GONG & 5 BEEPS SENSORSENSOR NUMBER FOR INTERIOR SENSOR NUMBER FOR CHIME8 FOR 8 TUV CHIME ZONE AWAY 1 BING DONE 7 FOR 7 PRS INTERIOR ZONE AWAY 1 BING DONEMAKING A SENSOR PERFORM A DIFFERENT FUNCTION SENSOR NUMBER FOR FUNCTION CHANGENEW FUNCTION NUMBER FOR SENSOR AWAY 1 BING DONE AWAYHOME = PROGRAM SETUP MODE12.ADVANCED PROGRAMMING TEST = REMOVEENTRY DELAY TIME CHANGING A SENSORS RESTORE REQUIREMENTSCHANGING A SENSORS SUPERVISION EXIT DELAY TIMEFIRE SIREN TIME REMOTE CONTROL ARMING LEVELREMOTE CONTROL DISARMING LEVEL AUTOMATION OUTPUT TIMEDISABLING QUICK ARMING SILENT BURGLARY ALARMSSILENT EMERGENCY ALARMS AUTOMATIC RESTORAL OF BYPASSED SENSORSAUTOMATION OUTPUT ON DURING AND AFTER ALARM AUTOMATION OUTPUT MODE DURING ALARMREMOTE CONTROL ARM/DISARM CHIRP AUTOMATION OUTPUT ON DURING ALARMAUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS REMOTE ACCESS PASSWORDAUTOMATION OUTPUT WHILE ARMED AUTOMATION OUTPUT POLARITYchanged using programming STEP #99 Because access to programming would be impossibleusing these steps. The master user code can be CONSOLE MASTER RESETGeneral Communicator Programming Table SETUP MODE13.COMMUNICATOR PROGRAMMING SETUP MODE2-WAYAUDIO COMMUNICATOR ENABLEGENERAL COMMUNICATOR OPTIONS VOICE RESPONSEDIALING METHOD CALL LIMITERDIALING DELAY 0PROGRAMMING STEP #101CALL ROUTING COMMUNICATOR REPORTING OPTIONSREPORTING FORMAT Communicator Reporting Option TableSECONDARY TELEPHONE NUMBER ACCOUNT NUMBERPRIMARY TELEPHONE NUMBER SUPERVISORY OR PAGER TELEPHONE NUMBEROPENING AND CLOSING REPORTS REPORT CONSOLE TROUBLEREPORT FORCE ARMING POINT ID REPORTINGSTEPS #201-206 COMMUNICATOR REPORTING CODESGENERAL REPORTING CODES General Reporting Codes TableFORCE ARMING REPORTING CODE SYSTEM REPORTING CODESSTEPS #261-266 DURESS REPORTING CODESTEPS #210-233 4 BY 2 FORMAT POINT ID ALARM REPORT CODES4 BY 2 FORMAT POINT ID REPORTING CODES 4 BY 2 FORMAT POINT ID TROUBLE REPORT CODESSTEP # 4 by 2 Format Point ID Reporting Code Table4 BY 2 FORMAT POINT ID REPORTING CODES PROGRAMMING FUNCTION14. IMPORTANT INFORMATION LINEAR LIMITED WARRANTYWIRELESS PRODUCT NOTICE FCC NOTICE
Related manuals
Manual 48 pages 58.1 Kb

DVS-2400 specifications

The Linear DVS-1200, DVS-2400, RA-2400, DUAL-824, and DVS-2408 are advanced digital video surveillance systems designed for a variety of security applications. These models offer state-of-the-art features, technologies, and characteristics that enhance security monitoring and recording capabilities.

The DVS-1200 is a compact and efficient digital video recorder that supports up to 12 channels of video input. It features high-resolution recording capabilities, providing clear and detailed images. With real-time playback and advanced motion detection, the DVS-1200 allows users to monitor activities effectively. Its user-friendly interface simplifies configuration and operation, making it accessible for both novice and experienced users.

Upgraded for larger installations, the DVS-2400 supports up to 24 channels. This model is equipped with H.264 video compression technology, significantly reducing storage requirements while maintaining high-quality images. The DVS-2400 also offers remote access capabilities, enabling users to view live footage or playback recorded events from anywhere using a smartphone or computer. Its built-in analytics features allow for motion detection, line crossing alerts, and more, enhancing overall security.

The RA-2400 is a remarkable model designed for robust performance in demanding environments. This recorder not only supports 24 channels but also integrates advanced RAID technology for data redundancy and enhanced storage reliability. The RA-2400 is ideal for applications where data loss is unacceptable, making it suitable for critical infrastructure and high-security locations.

The DUAL-824 model stands out with its unique dual-stream encoding feature. It allows simultaneous recording and streaming of two video resolutions, providing flexibility for different applications such as local monitoring and remote access. This model supports up to 8 channels and is equipped with advanced event triggers, ensuring significant activities do not go unnoticed.

Finally, the DVS-2408 is a versatile and high-performance system designed for larger facilities. With support for 24 channels and the ability to integrate with various IP cameras, the DVS-2408 delivers exceptional scalability. This model comes with comprehensive software for monitoring and management, allowing for multiple users and custom user permissions.