FIRE SIREN TIME

FIRE SIREN TIME

The factory-set fi re siren time is fi ve minutes (UL installation maximum).

STEP #32 The fi re siren time can be adjusted from one to 30 minutes using this step.

3DEF

PROGRAMMING STEP #32

2ABC

HOME PROGRAM

TIME IN MINUTES (1-30)

AWAY STORE PROGRAM

AUTOMATION OUTPUT TIME

The factory setting causes the Automation Output to toggle between on and off with each activation.

STEP #40 The Automation Output can be programmed to turn on, then automatically turn off after one to 2500 seconds (42 minutes), or toggle on & off, using this step.

4GHI

PROGRAMMING STEP #40

0

HOME PROGRAM

TIME IN SECONDS (1-2500) 0 = TOGGLE ON & OFF

AWAY STORE PROGRAM

REMOTE CONTROL ARMING LEVEL

The factory setting causes the portable remote controls to arm to the Away Mode.

STEP #50 The portable remote controls can be changed to arm to the Home Mode using this step.

NOTE: Changing this setting will affect all the portable remote controls used with the system.

5JKL

PROGRAMMING STEP #50

0

HOME PROGRAM

2 FOR HOME MODE

3 FOR AWAY MODE

AWAY STORE PROGRAM

REMOTE CONTROL DISARMING LEVEL

The factory setting causes the portable remote controls to disarm to the Off Mode.

STEP #51 The remote controls can be changed to disarm to the Chime Mode using this step.

NOTE: Changing this setting will affect all the portable remote controls used with the system.

5JKL

PROGRAMMING STEP #51

1

HOME PROGRAM

0 FOR OFF MODE

1 FOR CHIME MODE

AWAY STORE PROGRAM

ENTRY DELAY BEEPS

The factory setting causes the Console to beep during Entry Delays.

STEP #61 The Entry Delay beeps can be silenced using this step.

With the Entry Delay beeps off, the Console will be silent after a delayed sensor is triggered until the Entry Delay expires, then the alarm siren will sound.

6MNO

PROGRAMMING STEP #61

1

HOME PROGRAM

0 FOR ENTRY BEEPS OFF

1 FOR ENTRY BEEPS ON

AWAY STORE PROGRAM

EXIT DELAY BEEPS

The factory setting causes the Console to beep during Exit Delays.

STEP #62 The Exit Delay beeps can be silenced using this step.

With the Exit Delay beeps off, the Console will be silent after arming to the Away Mode until the Exit Delay expires, then a single “Gong” tone will sound.

6MNO

PROGRAMMING STEP #62

2ABC

HOME PROGRAM

0 FOR EXIT BEEPS OFF

1 FOR EXIT BEEPS ON

AWAY STORE PROGRAM

27

Image 29
Contents Installation & Programming Instructions SUPERVISED WIRELESS SECURITY CONSOLESECURITY USA & CanadaINTRODUCTION This symbol is for important notesTABLE OF CONTENTS CONSOLE 1.THE DVS-2400SECURITY SYSTEMREMOTE CONTROLS WIRELESS KEYPADDOOR/WINDOW SENSORS SMOKE DETECTOR2.SECURITY SYSTEM FLOOR PLAN DESIGN THE INSTALLATIONEXAMPLE SYSTEM Example Residential Security System Floor PlanDOOR/WINDOW SENSOR 3.TYPICAL SYSTEM SENSORSABOUT SENSOR STATUS SUPERVISION WIRELESS KEYPAD5 4 3 4.CONSOLE FEATURESSwitching to Off Mode stops the alarm siren Switching to Chime Mode stops the alarm sirenType 2AG, 1-ampfuse CONSOLE LOCATION 5.CONSOLE INSTALLATIONCASE LOCKING SCREW WALL MOUNTINGcan talk to the occupants through the external EXTERNAL CONSOLE SPEAKER CONNECTIONEXTERNAL ALARM SIREN CONNECTION Connect the Console to the telephone line if the TELEPHONE LINE CONNECTIONAUTOMATION OUTPUT CONNECTION OPTIONAL not plug the transformer in until the wiring is CONSOLE POWER CONNECTIONBACKUP BATTERY INSTALLATION OPTIONAL complete6.BASIC CONSOLE PROGRAMMING indicator for that sensor will stay litSTART IN TEST MASTER USER CODE 1 GONG & 5 BEEPSFollow the instructions on the previous page to PROGRAMMING DIFFERENT SENSOR TYPESselect a sensor number to program the sensor into For DXT-61, DXT-21, DXS-21, DXT-41,& DXS-62ADXS-10WIRELESS KEYPAD 7.BASIC SENSOR INSTALLATION4.Snap sensor onto mounting plate DXS-31& DXS-32DOOR/WINDOW SENSORSTEST SENSORS LABELING THE SENSORS 8.CUSTOMIZING THE CONSOLEcaused the alarm will fl ash and stops any alarms in progress9.CONSOLE OPERATING MODES OFF MODESECURE EXIT HOME MODESTART IN OFF OR CHIME MODE START IN HOME MODEQUICK ARM AWAY MODEOPTIONAL YOUR USER CODE 1 GONG & 3 BEEPS START HERE HOLDstatus indicators 3 beeps being the strongest signalTEST MODE START IN OFF10.SYSTEM TROUBLE INDICATIONS CONSOLE LOW BATTERYSENSOR LOW BATTERIES SENSOR RADIO TROUBLE11.CUSTOMIZING THE SYSTEM and the sensor status indicator will turn offACTIVATE SENSOR DONE START IN TEST MASTER USER CODE 1 GONG & 5 BEEPS SENSOR8 FOR 8 TUV CHIME ZONE AWAY 1 BING DONE SENSOR NUMBER FOR CHIMESENSOR NUMBER FOR INTERIOR 7 FOR 7 PRS INTERIOR ZONE AWAY 1 BING DONENEW FUNCTION NUMBER FOR SENSOR AWAY 1 BING DONE SENSOR NUMBER FOR FUNCTION CHANGEMAKING A SENSOR PERFORM A DIFFERENT FUNCTION AWAY12.ADVANCED PROGRAMMING SETUP MODEHOME = PROGRAM TEST = REMOVECHANGING A SENSORS SUPERVISION CHANGING A SENSORS RESTORE REQUIREMENTSENTRY DELAY TIME EXIT DELAY TIMEREMOTE CONTROL DISARMING LEVEL REMOTE CONTROL ARMING LEVELFIRE SIREN TIME AUTOMATION OUTPUT TIMESILENT EMERGENCY ALARMS SILENT BURGLARY ALARMSDISABLING QUICK ARMING AUTOMATIC RESTORAL OF BYPASSED SENSORSREMOTE CONTROL ARM/DISARM CHIRP AUTOMATION OUTPUT MODE DURING ALARMAUTOMATION OUTPUT ON DURING AND AFTER ALARM AUTOMATION OUTPUT ON DURING ALARMAUTOMATION OUTPUT WHILE ARMED REMOTE ACCESS PASSWORDAUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS AUTOMATION OUTPUT POLARITYusing these steps. The master user code can be Because access to programming would be impossiblechanged using programming STEP #99 CONSOLE MASTER RESET13.COMMUNICATOR PROGRAMMING SETUP MODEGeneral Communicator Programming Table SETUP MODEGENERAL COMMUNICATOR OPTIONS COMMUNICATOR ENABLE2-WAYAUDIO VOICE RESPONSEDIALING DELAY CALL LIMITERDIALING METHOD 0PROGRAMMING STEP #101REPORTING FORMAT COMMUNICATOR REPORTING OPTIONSCALL ROUTING Communicator Reporting Option TablePRIMARY TELEPHONE NUMBER ACCOUNT NUMBERSECONDARY TELEPHONE NUMBER SUPERVISORY OR PAGER TELEPHONE NUMBERREPORT FORCE ARMING REPORT CONSOLE TROUBLEOPENING AND CLOSING REPORTS POINT ID REPORTINGGENERAL REPORTING CODES COMMUNICATOR REPORTING CODESSTEPS #201-206 General Reporting Codes TableSTEPS #261-266 SYSTEM REPORTING CODESFORCE ARMING REPORTING CODE DURESS REPORTING CODE4 BY 2 FORMAT POINT ID REPORTING CODES 4 BY 2 FORMAT POINT ID ALARM REPORT CODESSTEPS #210-233 4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES4 BY 2 FORMAT POINT ID REPORTING CODES 4 by 2 Format Point ID Reporting Code TableSTEP # PROGRAMMING FUNCTIONWIRELESS PRODUCT NOTICE LINEAR LIMITED WARRANTY14. IMPORTANT INFORMATION FCC NOTICE
Related manuals
Manual 48 pages 58.1 Kb

DVS-2400 specifications

The Linear DVS-1200, DVS-2400, RA-2400, DUAL-824, and DVS-2408 are advanced digital video surveillance systems designed for a variety of security applications. These models offer state-of-the-art features, technologies, and characteristics that enhance security monitoring and recording capabilities.

The DVS-1200 is a compact and efficient digital video recorder that supports up to 12 channels of video input. It features high-resolution recording capabilities, providing clear and detailed images. With real-time playback and advanced motion detection, the DVS-1200 allows users to monitor activities effectively. Its user-friendly interface simplifies configuration and operation, making it accessible for both novice and experienced users.

Upgraded for larger installations, the DVS-2400 supports up to 24 channels. This model is equipped with H.264 video compression technology, significantly reducing storage requirements while maintaining high-quality images. The DVS-2400 also offers remote access capabilities, enabling users to view live footage or playback recorded events from anywhere using a smartphone or computer. Its built-in analytics features allow for motion detection, line crossing alerts, and more, enhancing overall security.

The RA-2400 is a remarkable model designed for robust performance in demanding environments. This recorder not only supports 24 channels but also integrates advanced RAID technology for data redundancy and enhanced storage reliability. The RA-2400 is ideal for applications where data loss is unacceptable, making it suitable for critical infrastructure and high-security locations.

The DUAL-824 model stands out with its unique dual-stream encoding feature. It allows simultaneous recording and streaming of two video resolutions, providing flexibility for different applications such as local monitoring and remote access. This model supports up to 8 channels and is equipped with advanced event triggers, ensuring significant activities do not go unnoticed.

Finally, the DVS-2408 is a versatile and high-performance system designed for larger facilities. With support for 24 channels and the ability to integrate with various IP cameras, the DVS-2408 delivers exceptional scalability. This model comes with comprehensive software for monitoring and management, allowing for multiple users and custom user permissions.

Together, these Linear video surveillance models represent a robust and reliable solution for modern security needs, featuring the latest technologies and high-quality performance to ensure safety and peace of mind in various environments.