Linear DVS-2400 manual Communicator Reporting Options, Reporting Format, Call Routing

Page 37
COMMUNICATOR REPORTING OPTIONS

COMMUNICATOR REPORTING OPTIONS

REPORTING FORMAT

The factory setting causes the communicator to report using the 4 BY 2 FORMAT. This format allows four-digit account numbers from 0000 to 9999 and provides two-digit alarm codes.

STEP #105 ADEMCO CONTACT ID can be chosen as a reporting format using this step. This format allows 4-digit account numbers from 0000 to 9999 and provides verbose report descriptions with Ademco Contact ID compatible Central Stations.

1

0PROGRAMMING STEP #105

5JKL

PROGRAM

HOME

0 FOR 4 BY 2

1 FOR ADEMCO CONTACT ID

AWAY

STORE PROGRAM

CALL ROUTING

The communicator can be programmed with three telephone numbers; primary, secondary, and supervisory.

The factory setting for the communicator is to route all calls to the primary telephone number. If communication is unsuccessful after five attempts to the primary number, the secondary number will be dialed for an additional five attempts. If the secondary number cannot be reached, the communicator will “sleep” for five minutes before starting the call process over again. A total of four sleep cycles (50 call attempts) can occur before the communicator stops calling.

8TUV

6MNO

HOME

AWAY

PROGRAMMING STEP #86

PROGRAM

0 FOR ALL TO PRIMARY/SECONDARY REPORTING FORMAT 1 FOR ALARMS ONLY TO

PRIMARY/SECONDARY

STORE PROGRAM

STEP #86 The communicator can be programmed to report supervisory events (low battery, trouble, AC failure, etc.) to the supervisory telephone number instead of the primary or secondary telephone numbers using this step.

CAUTION: If the page alert user code feature is going to be used, the supervisory number is reserved for the pager number. DO NOT SET THE CALL ROUTING OPTION TO “1”.

NOTE: To disable supervisory reports, set call routing option to “1” and remove the supervisory telephone number.

NOTE: Do not program the primary and secondary telephone numbers the same. See the FCC Telephone Rules and Regulations on the rear cover of this manual.

COMMUNICATOR REPORTING OPTIONS

STEP

PROGRAMMING

 

POSSIBLE

FACTORY

INSTALLATION

#

FUNCTION

 

 

VALUES

VALUE

VALUE

 

 

 

 

 

 

 

 

 

 

0

= ALL CALLS TO PRIMARY OR SECONDARY NUMBER

0

 

86

CALL ROUTING

 

1

= ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND ALL

 

 

 

 

 

OTHERS TO SUPERVISORY NUMBER

 

 

 

 

 

 

 

 

88

ACCOUNT NUMBER

 

4 DIGITS

EMPTY

 

 

 

 

 

 

 

89

PRIMARY PHONE NUMBER

 

UP TO 20 DIGITS

EMPTY

 

 

 

 

 

 

 

90

SECONDARY PHONE NUMBER

 

UP TO 20 DIGITS

EMPTY

 

 

 

 

 

 

91

SUPERVISORY/PAGER PHONE NUMBER

UP TO 20 DIGITS

EMPTY

 

 

 

 

 

 

 

 

 

 

PRESSING THE (A) KEY INSERTS A 1-SECOND DELAY

 

 

 

 

⇒ ⇒ ⇒

THE [FIRE] KEY INSERTS A 5-SECOND DELAY

 

 

 

FOR ALL PHONE NUMBERS

THE [CHIME] KEY INSERTS A “*

 

 

 

 

 

THE (A) KEY INSERTS A “#” IF IT IS THE LAST DIGIT OF THE PHONE NUMBER

 

 

105

REPORTING FORMAT

 

0

= 4 BY 2; 1 = ADEMCO

0

 

 

 

 

 

 

 

 

108

REPORT SYSTEM TROUBLE

 

0

= NO; 1 = YES

0

 

 

 

 

 

 

 

 

110

REPORT FORCE ARMING

 

0

= NO; 1 = YES

0

 

 

 

 

 

 

 

 

111

OPEN/CLOSE

 

0

= NO; 1 = YES; 2 = MASTER PAC ONLY

0

 

 

 

 

 

 

 

113

POINT ID REPORTING FOR 4 BY 2 FORMAT

0

= NO; 1 = YES

1

 

 

 

 

 

 

 

 

Communicator Reporting Option Table

35

Image 37
Contents Installation & Programming Instructions SUPERVISED WIRELESS SECURITY CONSOLESECURITY USA & CanadaINTRODUCTION This symbol is for important notesTABLE OF CONTENTS CONSOLE 1.THE DVS-2400SECURITY SYSTEMREMOTE CONTROLS WIRELESS KEYPADDOOR/WINDOW SENSORS SMOKE DETECTOR2.SECURITY SYSTEM FLOOR PLAN DESIGN THE INSTALLATIONEXAMPLE SYSTEM Example Residential Security System Floor PlanDOOR/WINDOW SENSOR 3.TYPICAL SYSTEM SENSORSABOUT SENSOR STATUS SUPERVISION WIRELESS KEYPAD5 4 3 4.CONSOLE FEATURESSwitching to Off Mode stops the alarm siren Switching to Chime Mode stops the alarm sirenType 2AG, 1-ampfuse CONSOLE LOCATION 5.CONSOLE INSTALLATIONCASE LOCKING SCREW WALL MOUNTINGEXTERNAL ALARM SIREN CONNECTION EXTERNAL CONSOLE SPEAKER CONNECTIONcan talk to the occupants through the external AUTOMATION OUTPUT CONNECTION OPTIONAL TELEPHONE LINE CONNECTIONConnect the Console to the telephone line if the not plug the transformer in until the wiring is CONSOLE POWER CONNECTIONBACKUP BATTERY INSTALLATION OPTIONAL complete6.BASIC CONSOLE PROGRAMMING indicator for that sensor will stay litSTART IN TEST MASTER USER CODE 1 GONG & 5 BEEPSFollow the instructions on the previous page to PROGRAMMING DIFFERENT SENSOR TYPESselect a sensor number to program the sensor into For DXT-61, DXT-21, DXS-21, DXT-41,& DXS-62ADXS-10WIRELESS KEYPAD 7.BASIC SENSOR INSTALLATIONTEST SENSORS DXS-31& DXS-32DOOR/WINDOW SENSORS4.Snap sensor onto mounting plate LABELING THE SENSORS 8.CUSTOMIZING THE CONSOLEcaused the alarm will fl ash and stops any alarms in progress9.CONSOLE OPERATING MODES OFF MODESECURE EXIT HOME MODESTART IN OFF OR CHIME MODE START IN HOME MODEQUICK ARM AWAY MODEOPTIONAL YOUR USER CODE 1 GONG & 3 BEEPS START HERE HOLDstatus indicators 3 beeps being the strongest signalTEST MODE START IN OFF10.SYSTEM TROUBLE INDICATIONS CONSOLE LOW BATTERYSENSOR LOW BATTERIES SENSOR RADIO TROUBLE11.CUSTOMIZING THE SYSTEM and the sensor status indicator will turn offACTIVATE SENSOR DONE START IN TEST MASTER USER CODE 1 GONG & 5 BEEPS SENSOR8 FOR 8 TUV CHIME ZONE AWAY 1 BING DONE SENSOR NUMBER FOR CHIMESENSOR NUMBER FOR INTERIOR 7 FOR 7 PRS INTERIOR ZONE AWAY 1 BING DONENEW FUNCTION NUMBER FOR SENSOR AWAY 1 BING DONE SENSOR NUMBER FOR FUNCTION CHANGEMAKING A SENSOR PERFORM A DIFFERENT FUNCTION AWAY12.ADVANCED PROGRAMMING SETUP MODEHOME = PROGRAM TEST = REMOVECHANGING A SENSORS SUPERVISION CHANGING A SENSORS RESTORE REQUIREMENTSENTRY DELAY TIME EXIT DELAY TIMEREMOTE CONTROL DISARMING LEVEL REMOTE CONTROL ARMING LEVELFIRE SIREN TIME AUTOMATION OUTPUT TIMESILENT EMERGENCY ALARMS SILENT BURGLARY ALARMSDISABLING QUICK ARMING AUTOMATIC RESTORAL OF BYPASSED SENSORSREMOTE CONTROL ARM/DISARM CHIRP AUTOMATION OUTPUT MODE DURING ALARMAUTOMATION OUTPUT ON DURING AND AFTER ALARM AUTOMATION OUTPUT ON DURING ALARMAUTOMATION OUTPUT WHILE ARMED REMOTE ACCESS PASSWORDAUTOMATION OUTPUT DURING EXIT/ENTRY DELAYS AUTOMATION OUTPUT POLARITYusing these steps. The master user code can be Because access to programming would be impossiblechanged using programming STEP #99 CONSOLE MASTER RESET13.COMMUNICATOR PROGRAMMING SETUP MODEGeneral Communicator Programming Table SETUP MODEGENERAL COMMUNICATOR OPTIONS COMMUNICATOR ENABLE2-WAYAUDIO VOICE RESPONSEDIALING DELAY CALL LIMITERDIALING METHOD 0PROGRAMMING STEP #101REPORTING FORMAT COMMUNICATOR REPORTING OPTIONSCALL ROUTING Communicator Reporting Option TablePRIMARY TELEPHONE NUMBER ACCOUNT NUMBERSECONDARY TELEPHONE NUMBER SUPERVISORY OR PAGER TELEPHONE NUMBERREPORT FORCE ARMING REPORT CONSOLE TROUBLEOPENING AND CLOSING REPORTS POINT ID REPORTINGGENERAL REPORTING CODES COMMUNICATOR REPORTING CODESSTEPS #201-206 General Reporting Codes TableSTEPS #261-266 SYSTEM REPORTING CODESFORCE ARMING REPORTING CODE DURESS REPORTING CODE4 BY 2 FORMAT POINT ID REPORTING CODES 4 BY 2 FORMAT POINT ID ALARM REPORT CODESSTEPS #210-233 4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES4 BY 2 FORMAT POINT ID REPORTING CODES 4 by 2 Format Point ID Reporting Code TableSTEP # PROGRAMMING FUNCTIONWIRELESS PRODUCT NOTICE LINEAR LIMITED WARRANTY14. IMPORTANT INFORMATION FCC NOTICE
Related manuals
Manual 48 pages 58.1 Kb

DVS-2400 specifications

The Linear DVS-1200, DVS-2400, RA-2400, DUAL-824, and DVS-2408 are advanced digital video surveillance systems designed for a variety of security applications. These models offer state-of-the-art features, technologies, and characteristics that enhance security monitoring and recording capabilities.

The DVS-1200 is a compact and efficient digital video recorder that supports up to 12 channels of video input. It features high-resolution recording capabilities, providing clear and detailed images. With real-time playback and advanced motion detection, the DVS-1200 allows users to monitor activities effectively. Its user-friendly interface simplifies configuration and operation, making it accessible for both novice and experienced users.

Upgraded for larger installations, the DVS-2400 supports up to 24 channels. This model is equipped with H.264 video compression technology, significantly reducing storage requirements while maintaining high-quality images. The DVS-2400 also offers remote access capabilities, enabling users to view live footage or playback recorded events from anywhere using a smartphone or computer. Its built-in analytics features allow for motion detection, line crossing alerts, and more, enhancing overall security.

The RA-2400 is a remarkable model designed for robust performance in demanding environments. This recorder not only supports 24 channels but also integrates advanced RAID technology for data redundancy and enhanced storage reliability. The RA-2400 is ideal for applications where data loss is unacceptable, making it suitable for critical infrastructure and high-security locations.

The DUAL-824 model stands out with its unique dual-stream encoding feature. It allows simultaneous recording and streaming of two video resolutions, providing flexibility for different applications such as local monitoring and remote access. This model supports up to 8 channels and is equipped with advanced event triggers, ensuring significant activities do not go unnoticed.

Finally, the DVS-2408 is a versatile and high-performance system designed for larger facilities. With support for 24 channels and the ability to integrate with various IP cameras, the DVS-2408 delivers exceptional scalability. This model comes with comprehensive software for monitoring and management, allowing for multiple users and custom user permissions.

Together, these Linear video surveillance models represent a robust and reliable solution for modern security needs, featuring the latest technologies and high-quality performance to ensure safety and peace of mind in various environments.