Carrier 48MPD Hsio Keypad and Display Module Functions and Subfunctions, SUB Functions

Page 44

Table 29 Ð HSIO Keypad and Display Module Functions and Subfunctions

SUB

 

 

FUNCTIONS

 

 

Status

History

Schedule

Service

Set Point

Test

FUNCTION

 

 

 

 

 

 

NO.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Occupied

 

 

 

1

Current

Alarms

Mode

Log on and

System

Test of

Alarms

Override

Log off

Set Point

Inputs

 

 

 

 

 

(Unit)

 

 

 

2

Current

Maintenance

Period 1

Software

Demand

Analog

Alerts

(Unit)

Version

Limit

Outputs

 

 

3

Current

 

Period 2

Factory

Current

Discrete

Operating

Ð

(Unit)

Con®guration

Time

Outputs

 

Modes

 

 

 

 

 

 

 

4

Capacity

 

Period 3

 

Daylight

Test

Ð

Bus Address

Savings

Stages

(Unit)

Compressors

 

 

 

Time

 

 

 

 

 

 

5

Current

 

Period 4

Units

Con®gure

 

Operating

Ð

Test Heat

(Unit)

of Measure

Holiday

 

Set Points

 

 

 

 

 

 

 

 

6

System

Ð

Period 5

User

Ð

Exit Test

Temperatures

(Unit)

Con®guration

 

 

 

 

7

System

Ð

Period 6

Heating Coil

Ð

Ð

Pressures

(Unit)

 

 

 

 

 

8

Inputs

Ð

Period 7

Cooling

Ð

Ð

(Unit)

 

 

 

 

 

 

9

Analog

Ð

Period 8

Duct Pressure

Ð

Ð

Outputs

(Unit)

 

 

 

 

 

 

 

 

Occupied

 

 

 

10

Discrete

Ð

Mode

Economizer

Ð

Ð

Outputs

Override

 

 

 

 

 

 

 

 

(TDO)

 

 

 

11

Run/

Ð

Period 1

Heat

Ð

Ð

Standby

(TDO)

 

 

 

 

 

12

Ð

Ð

Period 2

Nighttime

Ð

Ð

(TDO)

Free Cool

 

 

 

 

 

13

 

 

Period 3

Adaptive

 

 

Ð

Ð

Optimal

Ð

Ð

(TDO)

 

 

 

Start/Stop

 

 

 

 

 

 

 

 

14

Ð

Ð

Period 4

Temperature

Ð

Ð

(TDO)

Reset

 

 

 

 

 

15

Ð

Ð

Period 5

Con®gure

Ð

Ð

(TDO)

Loadshed

 

 

 

 

 

16

Ð

Ð

Period 6

Con®gure IAQ

Ð

Ð

(TDO)

 

 

 

 

 

 

17

Ð

Ð

Period 7

Con®gure

Ð

Ð

(TDO)

Humidity

 

 

 

 

 

18

Ð

Ð

Period 8

Building

Ð

Ð

(TDO)

Pressure

 

 

 

 

 

19

Ð

Ð

Ð

Alert Limits

Ð

Ð

20

Ð

Ð

Ð

Service History

Ð

Ð

21

 

 

 

Service

 

 

Ð

Ð

Ð

Maintenance

Ð

Ð

 

 

 

 

Alarm

 

 

22

Ð

Ð

Ð

Override History

Ð

Ð

LEGEND

IAQ Ð Indoor-Air Quality

TDO Ð Timed Discrete Output

44

Image 44
Contents Installation, Start-Up and Service Instructions ContentsGeneral ContentsSafety Considerations Installation Install Outdoor HoodsPhysical Data Base Unit 48/50MPPhysical Data Optional Power Exhaust Specications Compressor Oil ChargeVariable Frequency Drive VFD Physical Data FAN MotorRoof Curb Dimensions, 48/50MP62L and 70M Roof Curb Dimensions, 48/50MP82N-10R Base Unit Dimensions, 48MP62L, 70M Base Unit Dimensions, 48MP82N-10R Base Unit Dimensions, 50MP62L and 70M Base Unit Dimensions, 50MP82N-10R Unit Unit WeightSize Field Electrical Connections Make Electrical ConnectionsNEC EquipGND Electrical Data FLALRA MCARecommended Sensor Device Non-Shielded Cable ManufacturerSpace Temperature Sensor Wiring Space Temperature Sensor Averaging Heat Interlock Relay Outdoor Air¯ow Control Transducer/Thermistor CCN Connection Approved Shielded Cables Comm CCNCOM Auxiliary Control Box Location 50MP70M Unit Shown Installing Flue/Inlet Hoods 48MP Units Only Gas Piping DetailsCheck Compressor Mounting Flue De¯ector Baffle AssembledPRE-START-UP System CheckEvaporator-Fan Belts, Pulleys, and Sheaves Ð ExampleFan Performance Forward Curved Ð 48/50MP62L Fan Performance Forward Curved Ð 48/50MP70MFan Performance Forward Curved Ð 48/50MP82N Fan Performance Forward Curved Ð 48/50MP90PFan Performance Forward Curved Ð 48/50MP10R Fan Performance Air Foil Ð 48/50MP62LFan Performance Air Foil Ð 48/50MP70M Fan Performance Air Foil Ð 48/50MP82NFan Performance Air Foil Ð 48/50MP90P Fan Performance Air Foil Ð 48/50MP10RControls Conguration and Quick Test Keypad and Display Module Hsio Configuration Hsio Keypad Key UsageSet Point Ranges and Defaults SET Point Subfunction Display Default Range START-UPInitial Check Basic Conguration DataOccupied Cooling GeneralSupply FAN IGC Control Board LED Alarms OverridesControl Loop Checkout 48/50MP Units SMG, SCV and MLG Recommended Starting ValuesControl System ComponentsIndex of Lead/Lag Circuits Compressors Lead CircuitKeypad and Display Module Hsio Stby YESFunction Hsio Keypad and Display Module Functions and SubfunctionsSUB Functions Service Variable Frequency Drive VFD DisplayPower Exhaust MOTORS, PULLEYS, and Belts EVAPORATOR-FAN MOTORS, PULLEYS, and BeltsManufacturer Lubricant LubricationRefrigerant Circuit Charging Chart Ð Unit 48/50MP62L Charging Chart Unit 48/50MP90P Adjustments Pressure Switch Settings Psig kPagBelt Installation and Tensioning Switch Cutout CUT-IN06E Compressors, Typical Gas Valve Adjustment Protective DevicesMain Burner Removal Compressor ProtectionVariable Frequency Drive VFD Stby no Processor Modules PsioHigh-Voltage Relay Modules DSIO1 and DSIO2 Torque Compressors Compressor Replacement Ð Perform the followingTroubleshooting Troubleshooting and Diagnostics Problem Solution Compressor does not RUNCompressor Stops on HIGH-PRESSURE Switch Compressor Cycles on LOW-PRESSURE SwitchTroubleshooting and Diagnostics IGC Control Heating Ð 48MP Units Only Page Packaged Service Training Call for Free CatalogSTART-UP Checklist Model no Serial no Date TechnicianIII. Preliminary Checklist Items IV. START-UPCL-3 Fact Config Fanm

MPE62L-10R, 50MP62L-10R, 48MPD specifications

The Carrier 48MPD, 50MP62L-10R, and MPE62L-10R are advanced rooftop packaged units designed for a variety of commercial HVAC applications. These systems offer a compelling blend of energy efficiency, versatility, and high performance, making them ideal choices for businesses looking to enhance their indoor climate control.

One of the standout features of the Carrier 48MPD series is its high efficiency rating, which significantly reduces operational costs while minimizing environmental impact. The unit utilizes advanced scroll compressors that provide reliable and efficient cooling capabilities, ensuring optimal temperature regulation regardless of outdoor conditions. This innovative design also contributes to quieter operation, enhancing indoor comfort without disruptive noise levels.

The Carrier 50MP62L-10R model boasts superior cooling and heating capabilities, equipped with a multi-speed fan system that allows for tailored airflow to suit specific project requirements. This model's economizer feature is pivotal for harnessing outside air to offset mechanical cooling, leading to further energy savings, particularly in moderate weather conditions. Additionally, the unit's dual-fuel capability enhances its operational flexibility, allowing it to switch between electric and gas heating sources depending on efficiency needs.

In terms of control technologies, the MPE62L-10R is equipped with Carrier's advanced Smart Evaporator Control, which ensures precise humidity management while optimizing energy consumption. This model also integrates seamlessly with building automation systems, enabling remote monitoring and adjustments for greater operational oversight and efficiency. The intuitive user interface simplifies system programming and operation, making it accessible even for those without extensive technical backgrounds.

Another important characteristic of these units is their robust construction, designed to withstand challenging weather conditions and ensure longevity. The use of high-quality materials and components means lower maintenance costs over time.

Overall, the Carrier 48MPD, 50MP62L-10R, and MPE62L-10R represent a well-engineered suite of HVAC solutions that excel in efficiency, adaptability, and user-friendliness, establishing themselves as leading choices for commercial indoor climate management. With their blend of innovative technology and solid performance, these systems are well-suited to meet the diverse needs of modern commercial spaces.