Harman Stove Company P35I owner manual 7Appliance Set-Up, A. Outside Air Attachment

Page 18
7Appliance Set-Up

7Appliance Set-Up

P35i Fireplace Insert

A. Outside Air Attachment

Outside Air Kit #1-00-774280 (sold separately) must be used for attaching outside air to the insert. This kit contains a 3" stub and gasket to mount to the frame, and the outside air adapter which secures to the insert body. The outside air intake connection will seal to the mounting frame, just like the exhaust does. Follow the instructions included in the kit to ensure proper instal- lation.

1.Make a determination of where you want to draw the outside air from. Here are a few options.

a.Punch a hole through the rear of the fireplace and exterior wall. Rigid pipe or flex pipe could be used.

b.Use the chimney or chase as a conduit for outside air. The exhaust liner must be run the full length of the flue. When creating your steel plate to seal the damper area, Make another 3 inch hole for the outside air pipe. Install a short run of pipe from the mounting frame through the sealing plate. Then install the chimney top extension kit, item #1-00-674104 at the top of the chimney. This is slotted to allow fresh air into the chimney or chase.

2.Secure the outside air supply pipe to the stub on the mounting frame using a minimum of two fas- teners.

3.If running the supply pipe direct, install the outside air cover weldment #1-10-09542 to keep birds or rodents from entering the supply pipe.

4.Keep the intake a minimum of 4 feet (1.2 m) below the exhaust termination.

CAUTION!

Never draw outside combustion air from:

Wall, floor or ceiling cavity.

Enclosed space such as an attic or garage

The image at left shows the use of the chim- ney for outside air supply. Also shown is the Chimney intake extension on the top of the chimney. It is slotted to allow fresh air into the flue. Be sure to use the proper flashing and vent cap to prevent rain from entering the chimney flue.

The image below demonstrates bringing the outside air in through a hole cut through the rear of the fireplace and external wall. With this method, a screen is necessary to prevent birds or rodents from entering.

Contents of Outside Air Kit

Stub Mounting

BoltsSelf- drilling screws (2)

Intake Stub

Stub GasketA. Outside Air Attachment

Outside Air Intake

Manual backgroundWeldment

18 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

Image 18
Contents SAVE THESE INSTRUCTIONS ModelDiscard Installed, a House Fire May Result TABLE OF CONTENTS 1Listing and Code Approvals E. BTU & Efficiency SpecificationsC. Glass Specifications A. Appliance CertificationSPECIAL NOTE 2Special Warnings and NotesA. Design, Installation & Location Considerations B. Fire Safety3Getting Started Hopper Lid Latch C. Component LocationsP35i Fireplace Insert GlassD. Pre- Use Check List Fire Risk60.96 cm 4Dimensions & ClearancesA. Appliance Dimensions P35i Fireplace InsertMasonry or Manufactured Fireplace B. Clearances To CombustiblesD. Minimum Opening for Masonry and Manufactured FireplacesF. Factory-BuiltFireplace Installation Vent Information A. Vent Termination RequirementsVent Configurations B. Avoiding Smoke and OdorsNegative Pressure, Shut-down,and Power Failure Outside AirC.Venting Requirements and Restrictions WARNING! RISK OF FIREWARNING! RISK OF INJURY OR PROPERTY DAMAGE D. Existing Fireplace Installation Non-combustible InsulationSealing Plate F.Optional Zero Clearance Cabinet Installation E. Existing Fireplace, Rear VentVent pipe seams must be accessible A. Mobile Home Installation 6Mobile Home7Appliance Set-Up A. Outside Air AttachmentB. Installing the Surround C. Routing the Power CordD. Securing the Mounting Frame E. Attaching the VentingF.Installing the Body into the Mounting Frame G. Control Board InstallationH. Room Sensor Installation K. Service Rail Kit- #1-00-774125 I. Optional Log KitJ. Optional Trim Kit- #1-00-00775 Instructions A. Fire SafetyOperating B. Fuel and Fuel StorageC. General Operating Information 1. ESP Exhaust Sensing Probe2. Circuit Board e. Igniter Mode Switch a. Feed Rate Adjustmentd. Blower Speed Adjustment b. Mode SelectionE. Draft Test Procedure D. Before Your First FireF. Starting a Fire - MANUAL I. Relaxation Mode G. Starting a Fire - AUTOMATICH. Maintaining the Fire J. Shut-DownSymptom TroubleshootingError Message Possible CauseB. Quick Reference Maintenance Chart Service & MaintenanceA. Shut-downProcedure CAUTION! SHOCK AND SMOKE HAZARDC.General Maintenance Procedures WARNING! RISK OF FIRE 5.Cleaning Area Beneath Burn Pot Grate5.Cleaning Heat Exchanger & Exhaust By User6.Inspect / Clean Hopper By User8.Venting and Chimney System 7.Cleaning the Door GlassBy User Soot and Fly Ash Formation & Need for RemovalHopper Lid Latch D. Motors and ComponentsP35i Fireplace Insert Glass1.Feed Motor 2.Combustion Blower3.ESP- Exhaust Sensing Probe 4.Distribution Blower 5.Feeder Body6.Igniter 11Reference Materials PLUG PIN 11 WHITEP35i Fireplace Insert Addendum P35i Fireplace Insert9 10 11 12 13 P35i Pellet InsertPellet Insert 4 5 6Description #4 Surround AssemblyP35i Pellet Insert COMMENTSCOMMENTS P35i Pellet InsertDescription PART NUMBERCOMMENTS P35i Pellet InsertDescription PART NUMBERD. Custom Size Surround P35i Custom Surround Part #: 1-00-774221-SPLWARRANTY PERIOD LIMITED LIFETIME WARRANTYWARRANTY COVERAGE Hearth & Home Technologies IncThis warranty is void if WARRANTY CONDITIONSWARRANTY EXCLUSIONS LIMITATIONS OF LIABILITYDescription Of Service Service & Maintenance LogDate Of Service P35i Fireplace InsertProudly Printed On 100% Recycled Paper