Harman Stove Company P35I owner manual I. Optional Log Kit, J. Optional Trim Kit- #1-00-00775

Page 22
I. Optional Log Kit

P35i Fireplace Insert

I. Optional Log Kit

Ceramic log #3-40-674099 Log Bracket Kit #1-00-774401

Remove the two bolts from the air manifold below the glass opening. Install the log bracket using the same two bolts. Place the log onto the bracket with the smaller twigs pointing back toward the burn pot.

Please Note; The decorative log is fragile and must be handled with care. The abrasive nature of pellet ash may cause the log to deteriorate. Therefore, the log is not covered under the appliance warranty.

J. Optional Trim Kit- #1-00-00775-*

The trim kit option includes a door frame and an ash lip trim. To install the ash lip trim, simply slide it over the ash lip from the front. You can secure it with a few dabs of high temperature silicone, if desired. To install the door trim, follow these steps.

• Remove the door latch

 

by loosening the small

Set-screw

set-screw and tapping

 

out the roll pin.

 

• Remove the door

 

by lifting it off of the

 

hinges. Lay it, face

 

down on a flat surface.

Roll Pin

• Locate and drill the

 

dimpled holes in each

 

corner of the door,

 

using the provided drill

 

bit.

 

• Install the trim frame with

 

the threaded studs through

 

the holes in the door, and

 

secure it with the four nuts

 

provided in the kit.

 

* Trim finish suffix; 4=Gold, 7=Brushed Stainless, 8=Bright Nickel

K. Service Rail Kit- #1-00-774125

The Service Rail Kit is used to support the insert body while it is pulled out of the mounting frame for cleaning or service. Used only with a raised hearth installation, it is easily adjustable to a height range of 4" to 14". Assemble the rail kit using the provided instructions. After removing the Ash Pan cover, the rails attach to the mounting frame with four bolts. There are even stop bolts on the rails to prevent accidental roll-off.

Two bolts on each side secure the rail kit to the mounting frame.

22 Pellets or Corn/Pellet Mixture Only

3-90-775

Save These Instructions

Image 22
Contents Model SAVE THESE INSTRUCTIONSDiscard Installed, a House Fire May Result TABLE OF CONTENTS 1Listing and Code Approvals E. BTU & Efficiency SpecificationsC. Glass Specifications A. Appliance CertificationSPECIAL NOTE 2Special Warnings and NotesB. Fire Safety A. Design, Installation & Location Considerations3Getting Started Hopper Lid Latch C. Component LocationsP35i Fireplace Insert GlassD. Pre- Use Check List Fire Risk60.96 cm 4Dimensions & ClearancesA. Appliance Dimensions P35i Fireplace InsertMasonry or Manufactured Fireplace B. Clearances To CombustiblesD. Minimum Opening for Masonry and Manufactured FireplacesF. Factory-BuiltFireplace Installation Vent Information A. Vent Termination RequirementsVent Configurations B. Avoiding Smoke and OdorsNegative Pressure, Shut-down,and Power Failure Outside AirWARNING! RISK OF FIRE C.Venting Requirements and RestrictionsWARNING! RISK OF INJURY OR PROPERTY DAMAGE Non-combustible Insulation D. Existing Fireplace InstallationSealing Plate E. Existing Fireplace, Rear Vent F.Optional Zero Clearance Cabinet InstallationVent pipe seams must be accessible A. Mobile Home Installation 6Mobile Home7Appliance Set-Up A. Outside Air AttachmentB. Installing the Surround C. Routing the Power CordD. Securing the Mounting Frame E. Attaching the VentingG. Control Board Installation F.Installing the Body into the Mounting FrameH. Room Sensor Installation I. Optional Log Kit K. Service Rail Kit- #1-00-774125J. Optional Trim Kit- #1-00-00775 Instructions A. Fire SafetyOperating B. Fuel and Fuel Storage1. ESP Exhaust Sensing Probe C. General Operating Information2. Circuit Board e. Igniter Mode Switch a. Feed Rate Adjustmentd. Blower Speed Adjustment b. Mode SelectionD. Before Your First Fire E. Draft Test ProcedureF. Starting a Fire - MANUAL I. Relaxation Mode G. Starting a Fire - AUTOMATICH. Maintaining the Fire J. Shut-DownSymptom TroubleshootingError Message Possible CauseB. Quick Reference Maintenance Chart Service & MaintenanceA. Shut-downProcedure CAUTION! SHOCK AND SMOKE HAZARDC.General Maintenance Procedures WARNING! RISK OF FIRE 5.Cleaning Area Beneath Burn Pot Grate5.Cleaning Heat Exchanger & Exhaust By User6.Inspect / Clean Hopper By User8.Venting and Chimney System 7.Cleaning the Door GlassBy User Soot and Fly Ash Formation & Need for RemovalHopper Lid Latch D. Motors and ComponentsP35i Fireplace Insert Glass2.Combustion Blower 1.Feed Motor3.ESP- Exhaust Sensing Probe 4.Distribution Blower 5.Feeder Body6.Igniter PLUG PIN 11 WHITE 11Reference MaterialsP35i Fireplace Insert Addendum P35i Fireplace Insert9 10 11 12 13 P35i Pellet InsertPellet Insert 4 5 6Description #4 Surround AssemblyP35i Pellet Insert COMMENTSCOMMENTS P35i Pellet InsertDescription PART NUMBERCOMMENTS P35i Pellet InsertDescription PART NUMBERD. Custom Size Surround P35i Custom Surround Part #: 1-00-774221-SPLWARRANTY PERIOD LIMITED LIFETIME WARRANTYWARRANTY COVERAGE Hearth & Home Technologies IncThis warranty is void if WARRANTY CONDITIONSWARRANTY EXCLUSIONS LIMITATIONS OF LIABILITYDescription Of Service Service & Maintenance LogDate Of Service P35i Fireplace InsertProudly Printed On 100% Recycled Paper