D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).
Mantels (Combustible/Non-Combustible)
1,3 cm Thick Wall
Sheathing 30 cm
MAX.
MEASUREMENT
36 cm FROM TOP OF MIN. FIREPLACE
OPENING
Figure 5.3 Clearances To Combustible/Non-Combustible
Mantels Or Other Combustibles/Non-Combust-
ibles Above Appliance.
Note: For
Mantel Leg (Combustible/Non-Combustible)
TOP VIEW
8 cm
MINIMUM UNLIMITED
18 cm
Figure 5.4 Non-Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)
2,5 cm |
FRAMING |
NAILING TAB |
1,2 cm |
Figure 5.5 Front Side Finishing Detail
8,90 cm |
BOARD SHIPPED
WITH APPLIANCE
2,5 cm
2,5 cm
AIR SPACE
Figure 5.6 Non-Combustible Zone
Note: AIR SPACE denoted in Figure 5.6 is defined by the nailing tabs and metal standoffs.