Heat & Glo LifeStyle XLR-PB-CE, XLR-N-CE manual Table of Contents, User Guide

Page 3

Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification. . . . . . . . . . . . . . . 7 A. Additional Related Standards. . . . . . . . . . . . 7 B. Gas Pressure Requirements . . . . . . . . . . . . 7

C.Non-Combustible Materials Specification. . . . . . . . . . . . . . 7

D.Combustible Materials Specification . . . . . . . . . 7

E.Electrical Codes. . . . . . . . . . . . . . . . . 7

User Guide

2 Operating Instructions

A. Gas Fireplace Safety. . . . . . . . . . . . . . . 8 B. Your Fireplace . . . . . . . . . . . . . . . . . . 8 C. Clear Space. . . . . . . . . . . . . . . . . . . 9 D. Decorative Doors and Fronts. . . . . . . . . . . . 9 E. Decorative Media Options . . . . . . . . . . . . . 9 F. Fixed Glass Assembly . . . . . . . . . . . . . . . 9 G. Remote Controls, Wall Controls and Wall Switches. . . . 9 H. Before Lighting Fireplace. . . . . . . . . . . . . . 9

I.Control Module Operation . . . . . . . . . . . . . 10

J.Lighting Instructions (IPI). . . . . . . . . . . . . 11

K.Battery Tray/Battery Installation. . . . . . . . . . . 12

M. Frequently Asked Questions . . . . . . . . . . . . 12 L. After Fireplace is Lit. . . . . . . . . . . . . . . 12

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . 13 B. Maintenance Tasks-Qualified Service Technician . . . . 14

Installer Guide

4 Getting Started

A.Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 15

B.Design and Installation Considerations . . . . . . . . 16

C.Tools and Supplies Needed. . . . . . . . . . . . 16

D.Inspect Appliance and Components. . . . . . . . . 16

5 Framing and Clearances

A. Selecting Appliance Location. . . . . . . . . . . . 17 B. Constructing the Appliance Chase. . . . . . . . . . 18 C. Clearances. . . . . . . . . . . . . . . . . . . 19 D. Mantel and Wall Projections. . . . . . . . . . . . 20

6 Termination Locations

A. Vent Termination Minimum Clearances. . . . . . . . 21

7 Vent Information and Diagrams

A. Approved Pipe. . . . . . . . . . . . . . . . . 23 B. Vent Table Key. . . . . . . . . . . . . . . . . 23 C. Use of Elbows . . . . . . . . . . . . . . . . . 23 D. Measuring Standards. . . . . . . . . . . . . . . 23 E. Vent Diagrams. . . . . . . . . . . . . . . . . 23

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . 30 B. Wall Penetration Framing. . . . . . . . . . . . . 30 C. Install the Ceiling Firestop . . . . . . . . . . . . . 31 D. Install Attic Insulation Shield. . . . . . . . . . . . 32

9 Appliance Preparation

A.

Top Vent

. . . . .

. 33

B.

Securing and Leveling the Appliance. . .

. . . . .

. 34

10 Installing Vent Pipe (SLP Pipe)

A.Assemble Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . . 35

B.Assemble Slip Sections. . . . . . . . . . . . . . 36

C.Secure The Vent Sections. . . . . . . . . . . . . 36

D.Disassemble Vent Sections. . . . . . . . . . . . 37

E.Install Decorative Ceiling Components . . . . . . . . 37

F.Install Metal Roof Flashing. . . . . . . . . . . . . 38

G.Assemble and Install Storm Collar. . . . . . . . . . 38

H.Install Vertical Termination Cap . . . . . . . . . . . 39

I.Install Decorative Wall Components . . . . . . . . . 39

J.Heat Shield Requirements for Horizontal Termination. . 39

K.Install Horizontal Termination Cap. . . . . . . . . . 40

11 Gas Information

A. Gas Pressure Requirements . . . . . . . . . . . . 41 B. Gas Connection. . . . . . . . . . . . . . . . . 41 C. Access Through the Valve Assembly. . . . . . . . . 41

12 Electrical Information

A. Wiring Requirements. . . . . . . . . . . . . . . 42 B. IntelliFire Plus™ Ignition System Wiring . . . . . . . 42 C. Optional Accessories Requirements . . . . . . . . . 42 D. Electrical Service and Repair. . . . . . . . . . . . 43 E. Junction Cord Information . . . . . . . . . . . . . 43 F. Blower . . . . . . . . . . . . . . . . . . . . 43

13 Finishing

A. Framing and Finishing Instructions . . . . . . . . . 44 B. Mantel and Wall Projections. . . . . . . . . . . . 47 C. Facing Material. . . . . . . . . . . . . . . . . 47

Heat & Glo • XLR-N-CE, XLR-PB-CE2198-900 Rev. J • 5/12

3

Image 3
Contents What to do if you smell gas EC-87/09/058Homeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting Component AccessLimited Lifetime Warranty Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions Limited Lifetime WarrantyListing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Decorative Doors and Fronts Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear Space Nine Hour Safety Shutdown Feature Module Reset SwitchControl Module Operation Lighting Instructions IPI Final inspection byAGE 110/120 VAC or 220/240 After Fireplace is Lit Battery Tray/Battery InstallationFrequently Asked Questions Initial Break-in ProcedureDecorative Doors Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningControl Compartment and Firebox Top Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection FireboxTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase Clearances Minimum Framing DimensionsMantel and Wall Projections Mantels Combustible/Non-CombustibleMantel Leg Combustible/Non-Combustible Vent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Vent Information and Diagrams Minimum Maximum Top Vent Horizontal Termination Venting with 1 elbowTop Vent Horizontal Termination Venting with 2 elbows Exhaust restrictor Instructions Top Vent Vertical Termination No Elbows V1 = 13,4 mV1 Minimum Maximum V1 + V2 Minimum Top Vent Vertical Termination Venting with 2 elbowsV1 Minimum H1 + H2 Maximum V1 + V2 Minimum Top Vent Vertical Termination Venting with 3 elbowsMin Max Top Vent Vertical Termination Venting with 4 elbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe SLP Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Top Vent Appliance PreparationProper Positioning, Leveling And Securing of an Securing and Leveling the ApplianceAssemble Vent Sections Installing Vent Pipe SLP PipeSecure The Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingInstall Vertical Termination Cap Install Decorative Wall ComponentsHeat Shield Requirements for Horizontal Termination 17 Venting through the wall Install Horizontal Termination CapAccess Through the Valve Assembly Gas InformationGas Pressure Requirements Gas Connection Optional Remote Control Receiver and Battery Pack Location Wiring RequirementsIntelliFire Plus Ignition System Wiring Optional Accessories RequirementsJunction Cord Information Electrical Service and Repair BlowerFinishing Instructions Non-Combustible Materials SpecificationFinishing Framing and Finishing InstructionsFACTORY-INST Alled Wallboard Joint-Crack Prevention and Repair Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard PaintingOverlap Fit Method Tonic or Martini Decorative Front Facing MaterialNon-Combustible Finish Material 0-10 cm Thick Decorative Fronts Dimensions of Tonic Decorative FrontAppliance Setup Air Shutter Setting Air Shutter SettingsMedia Options Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System Ues to spark, and main Component Access Valve Assembly Gasket Pilot Assembly Replacement Gas Valve ReplacementReference Materials Appliance Dimension DiagramVent Components Diagrams Ceiling Firestop SLP-45 45 ElbowSLP90- 90 Elbow Extended Heat ShieldBlack 30,5 cm 17,8 cm 39,4 cm SnorkelSupport Box-Black AdapterSLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP Landscape DV Appliance Service Parts#14 Valve Assembly XLR-N-CE, XLR-PB-CE Service Parts ListContact Information