Heat & Glo LifeStyle CERONA-42 Vent Information and Diagrams, Vent Table Key, Use of Elbows

Page 14

5 Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Second section of horizontal length

 

 

WARNING

Fire Hazard. Explosion Risk. Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney flue serving a separate solid-fuel or gas burning appliance.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

B. Use of Elbows

CAUTION

ALL vent configuration specifications MUST be followed.

This product is tested and listed to these specifications.

Appliance performance will suffer if specifications are not followed.

Diagonal runs have both vertical and horizontal vent as- pects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 5.1).

Two 45º elbows may be used in place of one 90º elbow. On 45º runs, one foot of diagonal is equal to 8.5 inches hori- zontal run and 8.5 inches vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 5.1).

Verticalin. 1/2-8

8-1/2 in.

Horizontal

Figure 5.1

C. Measuring Standards

Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.

1.Pipe measurements are shown using the effective length of pipe (see Figure 5.2).

2.Measurements are made from the appliance outer wrap, not from the standoffs.

3.Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 4.1).

4.Vertical terminations are measured to bottom of termi- nation cap.

5.Horizontal pipe installed level with no rise.

 

Pipe

Effective Length

 

Inches

Millimeters

 

 

 

DVP4

4

102

 

DVP6

6

152

Effective

DVP12

12

305

Height/Length

DVP24

24

610

 

 

DVP36

36

914

 

DVP48

48

1219

 

DVP6A

3 to 6

76 to 152

 

DVP12A

3 to 12

76 to 305

 

DVP12MI

3 to 12

76 to 305

 

DVP24MI

3 to 24

76 to 610

Figure 5.2 DVP Pipe Effective Length

 

 

14

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. F • 04/08

Image 14
Contents Models What to do if you smell gasHomeowner Reference Information Model Number Serial NumberTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Read all of the instructions before starting the instaFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel Projections 724 425 406 279Hearth Extension Dimensions Hearth ExtensionTermination Locations Vent Termination Minimum ClearancesAlcove Applications Minimum Clearances for TerminationContinue Adding Vent Components Install Support BracketsTo Install the Heat Shield Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow V1 = 50 ft. Max .2 m Top Vent Horizontal Termination Three ElbowsTop Vent Vertical Termination Straight up Vertical Venting 152 mm 914 mm 305 mm 610 mm 10 ftTop Vent Horizontal Termination Two Elbows 305 mm 610 mm 914 mm 10 ftWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Removing Non-combustible Facing Mate- rial Assembly Appliance PreparationProvided to secure the appliance to the framing members Diagram shows .2 the location of the nailing tabsSecuring and Leveling the Appliance Installing Flue Restrictors Complete Installation of Non-combustible Facing MaterialAttaching Vent to the Firebox Assembly Installing Vent PipeAssembly of Vent Sections Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsVertical Sections Disassembly of Vent SectionsSecuring the Vent Sections Horizontal SectionsHeat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Heat shield DVP-HSM-B must be usedInstalling Roof Flashing and Vertical Ter- mination Cap flue of the pipe see FigureAssembling and Installing Storm Collar 18 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas Connection High Altitude Installations Connecting to the Appliance Recommendation for WireIntellifire Ignition System Wiring Optional Accessories RequirementsNot operate unless Properly groundedJunction Box Installation Junction Box DetailStep Finishing Facing Material Non-combustible Facing MaterialFinishing Material Thickness greater than 1-1/4 inch Finishing Material OptionsFinishing Material Thickness from 3/4 in. to 1-1/4 Mounting stone eye brow ATRIMSTONE-36, ATRIMSTONE-4210 Fireplace sitting on combustible surface Accessories Appliance SetupClean the Appliance Ember PlacementLog Assembly LOGS-Cerona36 Positioning the Logs Model Cerona-36Heat & Glo Cerona-36, Cerona-42 2106-900 Rev. F 04/08 Model Cerona-42 Step Grilles and Trim Glass AssemblyAir Shutter Setting This appliance has an Intellifire ignition system Operating InstructionsBefore Lighting Appliance Lighting Appliance IPI Ignition Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsModel Cerona-36 Model Cerona-42 Appliance Dimension DiagramReference Materials Vent Components Diagrams DVP vent componentsDVP-TRAP COOL-ADD Not for use with these models Part number list on following Log Set AssemblyService Parts Service Parts List At DepotIPI Valve Assembly StockedCERONA-42 CERONA-42 Fan Kit GFK-160A Junction Box 4021-013 Box Paint KitIPI Valve Assembly Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information
Related manuals
Manual 62 pages 22.54 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.