10 Electrical Information
A. Recommendation for Wire
This appliance requires
Note: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
C. Intellifire Ignition System Wiring
This appliance requires a 110 VAC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.1.
This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the sup- plied junction box. It is highly recommended that the junc- tion box be installed at this time to avoid reconstruction.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
•Incorrect wiring will damage millivolt valves.
•Incorrect wiring will override IPI safety lockout and may cause explosion.
The battery pack requires two D cell batteries (not includ- ed). Batteries cannot be placed in the battery pack while using the 3 volt transformer. Batteries shouldn’t be placed into the holder until needed. The higher temperatures will shorten their life.
CAUTION
Battery polarity must be correct or module damage will occur.
•This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.
•If using thermostat use one compatible with a millivolt gas valve system.
•Follow parameters for locating thermostat (see individual thermostat instructions) to ensure proper operation of appliance.
•Use low resistance thermostat wire for wiring from ignition system to the wall switch and thermostat.
•Keep wire lengths short as possible by removing any excess wire length.
•Low voltage and 110 VAC voltage cannot be shared within the same wall box.
Optional Accessories Requirements
Wiring for optional accessories should be done now to avoid reconstruction.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING
Shock hazard.
•Replace damaged wire with type 105º C rated wire.
•Wire must have high temperature insulation.