Heat & Glo LifeStyle CERONA-36, CERONA-42 Installing Roof Flashing and Vertical Ter- mination Cap

Page 27

E.Installing Roof Flashing and Vertical Ter- mination Cap

To install roof flashing see Figure 8.16.

For installation of vertical termination cap see minimum vent heights for various pitched roofs (see Figure 8.14).

HORIZONTAL

OVERHANG

Caulk the gap between the roof flashing and the outside diameter of the pipe. Also caulk the perimeter of flashing that contacts roof surface as shown in Figure 8.16.

To attach the vertical termination cap, slide the inner col- lar of the cap into the inner flue of the pipe section and place the outer collar of the cap over the outer flue of the pipe section.

Secure with three screws into the outer flue. Secure the cap by driving the three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer

2FT.

MIN.

GAS DIRECT VENT

TERMINATION CAP

20 INCHES MIN.

VERTICAL

LOWEST

WALL

 

DISCHARGE

 

OPENING

 

X

12

ROOF PITCH

IS X/ 12

H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING

flue of the pipe (see Figure 8.15).

TERMINATION CAP

(1 of 3)

Roof Pitch

H (Min.) Ft.

Flat to 6/12

1.0*

Over 6/12 to 7/12

1.25*

Over 7/12 to 8/12

1.5*

Over 8/12 to 9/12

2.0*

Over 9/12 to 10/12

2.5

Over 10/12 to 11/12

3.25

Over 11/12 to 12/12

4.0

Over 12/12 to 14/12

5.0

Over 14/12 to 16/12

6.0

Over 16/12 to 18/12

7.0

Over 18/12 to 20/12

7.5

Over 20/12 to 21/12

8.0

* 3 foot minimum in snow regions

Figure 8.14 Minimum height from roof to lowest discharge opening

WARNING

Fire Risk.

Explosion Risk.

Inspect external vent cap regularly.

Ensure no debris blocks cap.

Combustible materials blocking cap may ignite.

Restricted air flow affects burner operation.

STORM

COLLAR

SCREWS

CAULK

Figure 8.15

CAULK

Figure 8.16

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. F • 04/08

27

Image 27
Contents What to do if you smell gas ModelsModel Number Serial Number Homeowner Reference InformationTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsRead all of the instructions before starting the insta Installation to ensure maximum safety and benefitGetting Started Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance Chase724 425 406 279 Mantel ProjectionsHearth Extension Hearth Extension DimensionsVent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Alcove ApplicationsInstall Support Brackets To Install the Heat ShieldContinue Adding Vent Components Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows 152 mm 914 mm 305 mm 610 mm 10 ft Top Vent Horizontal Termination Three ElbowsTop Vent Vertical Termination Straight up Vertical Venting V1 = 50 ft. Max .2 m305 mm 610 mm 914 mm 10 ft Top Vent Horizontal Termination Two ElbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Mate- rial AssemblyDiagram shows .2 the location of the nailing tabs Securing and Leveling the ApplianceProvided to secure the appliance to the framing members Complete Installation of Non-combustible Facing Material Installing Flue RestrictorsAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical SectionsHeat shield DVP-HSM-B must be used Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Heat Shield Requirements for Horizontal Terminationflue of the pipe see Figure Installing Roof Flashing and Vertical Ter- mination Cap18 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarGas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Optional Accessories Requirements Recommendation for WireIntellifire Ignition System Wiring Connecting to the ApplianceProperly grounded Not operate unlessJunction Box Detail Junction Box InstallationStep Finishing Non-combustible Facing Material Facing MaterialMounting stone eye brow ATRIMSTONE-36, ATRIMSTONE-42 Finishing Material OptionsFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material Thickness greater than 1-1/4 inch10 Fireplace sitting on combustible surface Ember Placement Appliance SetupClean the Appliance AccessoriesPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36Heat & Glo Cerona-36, Cerona-42 2106-900 Rev. F 04/08 Model Cerona-42 Step Glass Assembly Air Shutter SettingGrilles and Trim Operating Instructions Before Lighting ApplianceThis appliance has an Intellifire ignition system Final inspection by Lighting Appliance IPI IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsModel Cerona-36 Model Cerona-42 DVP vent components Vent Components DiagramsDVP-TRAP COOL-ADD Not for use with these models Log Set Assembly Service PartsPart number list on following At Depot Service Parts ListStocked IPI Valve AssemblyCERONA-42 Fan Kit GFK-160A Junction Box 4021-013 Box Paint Kit CERONA-42IPI Valve Assembly Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information
Related manuals
Manual 62 pages 22.54 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.