Heat & Glo LifeStyle CERONA-36, CERONA-42 Operating Instructions, Before Lighting Appliance

Page 45

13 Operating Instructions

A. Before Lighting Appliance

This appliance has an Intellifire ignition system.

CAUTION

If installing Intellifire ignition battery backup:

Do not install batteries if the backup mode may not be used for extended time.

Batteries may leak.

Install batteries only when needed for power outage.

Before operating this appliance have a qualified tech- nician:

Remove all shipping materials from inside and/or underneath the firebox.

Review proper placement of logs and ember material.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position.

Ensure that the flow of combustion and ventilation air is not obstructed (front grilles and vent caps).

WARNING

Glass door must be in place when appliance is operating.

Risk of:

• Combustion Fumes

• Fire

Do NOT operate appliance with glass door removed.

Open viewing glass for servicing only.

Glass door MUST be in place and sealed before operating appliance.

Only use glass door certified for use with appliance.

Glass replacement should be done by qualified technician.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. F • 04/08

45

Image 45
Contents What to do if you smell gas ModelsModel Number Serial Number Homeowner Reference InformationTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Read all of the instructions before starting the instaSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance Chase724 425 406 279 Mantel ProjectionsHearth Extension Hearth Extension DimensionsVent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Alcove ApplicationsInstall Support Brackets To Install the Heat ShieldContinue Adding Vent Components Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows Top Vent Vertical Termination Straight up Vertical Venting Top Vent Horizontal Termination Three ElbowsV1 = 50 ft. Max .2 m 152 mm 914 mm 305 mm 610 mm 10 ft305 mm 610 mm 914 mm 10 ft Top Vent Horizontal Termination Two ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Mate- rial AssemblyDiagram shows .2 the location of the nailing tabs Securing and Leveling the ApplianceProvided to secure the appliance to the framing members Complete Installation of Non-combustible Facing Material Installing Flue RestrictorsAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Disassembly of Vent SectionsVertical Sections Horizontal SectionsInstalling the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Heat shield DVP-HSM-B must be usedflue of the pipe see Figure Installing Roof Flashing and Vertical Ter- mination Cap18 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarGas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Optional Accessories RequirementsProperly grounded Not operate unlessJunction Box Detail Junction Box InstallationStep Finishing Non-combustible Facing Material Facing MaterialFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material OptionsFinishing Material Thickness greater than 1-1/4 inch Mounting stone eye brow ATRIMSTONE-36, ATRIMSTONE-4210 Fireplace sitting on combustible surface Clean the Appliance Appliance SetupAccessories Ember PlacementPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36Heat & Glo Cerona-36, Cerona-42 2106-900 Rev. F 04/08 Model Cerona-42 Step Glass Assembly Air Shutter SettingGrilles and Trim Operating Instructions Before Lighting ApplianceThis appliance has an Intellifire ignition system Final inspection by Lighting Appliance IPI IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsModel Cerona-36 Model Cerona-42 DVP vent components Vent Components DiagramsDVP-TRAP COOL-ADD Not for use with these models Log Set Assembly Service PartsPart number list on following At Depot Service Parts ListStocked IPI Valve AssemblyCERONA-42 Fan Kit GFK-160A Junction Box 4021-013 Box Paint Kit CERONA-42IPI Valve Assembly Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information
Related manuals
Manual 62 pages 22.54 Kb Manual 1 pages 2.44 Kb

CERONA-42, CERONA-36 specifications

The Heat & Glo LifeStyle CERONA-36 and CERONA-42 are elegant gas fireplaces designed to enhance the ambiance of any living space while providing effective heating solutions. These models stand out due to their sleek design and innovative technologies that cater to modern homeowners seeking both comfort and style.

One of the primary features of the CERONA series is their clean, contemporary aesthetic. The linear design maximizes the display of flames and minimizes visual distractions, making them a focal point in any room. With options for various finishes and customizable media, including glass and logs, homeowners can truly personalize their fireplace to match their décor.

The CERONA-36 and CERONA-42 are equipped with advanced burner technology that ensures an exceptional flame presentation. The high-efficiency burners not only produce beautiful flames but also optimize heat output while maintaining energy efficiency. These fireplaces are designed to provide warmth without sacrificing environmental consciousness, making them an ideal choice for eco-aware consumers.

Both models come with Heat & Glo's patented IntelliFire Technology, which allows for adaptive ignition and reliable operation. This technology ensures that the fireplace ignites quickly and safely, providing peace of mind for users. Additionally, the remote control feature allows for easy operation from anywhere in the room, enhancing convenience when it comes to controlling the temperature and ambiance.

The CERONA series also incorporates a unique Power Vent technology. This enables the fireplace to vent up to 40 feet horizontally and vertically, offering flexibility in installation and allowing for greater design possibilities for any space in the home.

Moreover, the fireplaces are designed with sound-dampening features that reduce operational noise, ensuring a peaceful ambiance while maximizing the visual experience of dancing flames.

The straightforward maintenance and cleaning requirements of the CERONA-36 and CERONA-42 further contribute to their appeal. With a user-friendly design, these fireplaces simplify upkeep, making them suitable for busy lifestyles.

In summary, the Heat & Glo LifeStyle CERONA-36 and CERONA-42 gas fireplaces are remarkable heating solutions that combine aesthetics, technology, and user convenience. Their modern design, efficient operation, and adaptable installation options make them a valuable addition to any contemporary home, ensuring both warmth and elegance for years to come.