Heat & Glo LifeStyle CERONA-36 Vent Diagrams, Top Vent Horizontal Termination One Elbow

Page 15

D. Vent Diagrams

WARNING

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

Install wall shield and ceiling firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

1. Top Vent - Horizontal Termination

One Elbow

V1

H1

Figure 5.3

 

V1 Minimum

H1 Maximum

Cerona-36 ONLY

1/2 ft

152 mm

2 ft

 

610 mm

 

1 ft

305 mm

2 ft

 

610 mm

 

2 ft

610 mm

5 ft

 

1.5 m

 

3 ft

914 mm

8 ft

 

2.4 m

 

4 ft

 

1.2 m

11 ft

 

3.4 m

 

5 ft

 

1.5 m

14 ft

 

4.3 m

 

6 ft

 

1.8 m

17 ft

 

5.2 m

 

7 ft

 

2.1 m

20 ft

 

6.1 m

 

8 ft

 

2.4 m

23 ft

 

7.0 m

 

V1 = 40 ft. (12.2 m) Maximum

 

H1

= 23 ft. (7.0 m) Maximum

 

V1 + H1 = 63 ft. (19.2 m) Maximum

Note: Must have

Minimal Vertical Vent

a minimum verti-

Model

 

ft.

mm

cal vent before

 

Cerona-36

1/2

152

attaching a 90º

elbow to the unit.

Cerona-42

1

305

See chart.

 

 

 

 

 

Two Elbows

H2

 

V1 Minimum

H1 Maximum

Cerona-36 ONLY

1/2 ft

152 mm

2 ft

610 mm

 

1 ft

305 mm

2 ft

610 mm

 

2 ft

610 mm

5 ft

1.5 m

 

3 ft

914 mm

8 ft

2.4 m

 

4 ft

1.2 m

11 ft

3.4 m

 

5 ft

1.5 m

14 ft

4.3 m

 

6 ft

1.8 m

17 ft

5.2 m

V1

7 ft

2.1 m

20 ft

6.1 m

8 ft

2.4 m

23 ft

7.0 m

H1

V1 + H1

+ H2= 63 ft. (19.2 m) Maximum

 

 

H1 + H2 = 23 ft. (7.0 m) Maximum

INSTALLED

Note: Must have

Minimal Vertical Vent

HORIZONTALLY

 

a minimum verti-

Model

ft.

mm

 

cal vent before

 

Cerona-36

1/2

152

 

attaching a 90º

 

elbow to the unit.

Cerona-42

1

305

 

See chart.

 

 

 

Figure 5.4

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. F • 04/08

15

Image 15 Contents
What to do if you smell gas ModelsModel Number Serial Number Homeowner Reference InformationTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsRead all of the instructions before starting the insta Installation to ensure maximum safety and benefitGetting Started Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance Chase724 425 406 279 Mantel ProjectionsHearth Extension Hearth Extension Dimensions Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Alcove ApplicationsInstall Support Brackets To Install the Heat ShieldContinue Adding Vent Components Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows 152 mm 914 mm 305 mm 610 mm 10 ft Top Vent Horizontal Termination Three ElbowsTop Vent Vertical Termination Straight up Vertical Venting V1 = 50 ft. Max .2 m305 mm 610 mm 914 mm 10 ft Top Vent Horizontal Termination Two ElbowsCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Appliance Preparation Removing Non-combustible Facing Mate- rial AssemblyDiagram shows .2 the location of the nailing tabs Securing and Leveling the ApplianceProvided to secure the appliance to the framing members Complete Installation of Non-combustible Facing Material Installing Flue RestrictorsAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical SectionsHeat shield DVP-HSM-B must be used Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Heat Shield Requirements for Horizontal Terminationflue of the pipe see Figure Installing Roof Flashing and Vertical Ter- mination Cap18 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarGas Information Fuel Conversions Gas ConnectionGas Pressures High Altitude Installations Optional Accessories Requirements Recommendation for WireIntellifire Ignition System Wiring Connecting to the ApplianceProperly grounded Not operate unlessJunction Box Detail Junction Box InstallationStep Finishing Non-combustible Facing Material Facing MaterialMounting stone eye brow ATRIMSTONE-36, ATRIMSTONE-42 Finishing Material OptionsFinishing Material Thickness from 3/4 in. to 1-1/4 Finishing Material Thickness greater than 1-1/4 inch10 Fireplace sitting on combustible surface Ember Placement Appliance SetupClean the Appliance AccessoriesPositioning the Logs Model Cerona-36 Log Assembly LOGS-Cerona36Heat & Glo Cerona-36, Cerona-42 2106-900 Rev. F 04/08 Model Cerona-42 Step Glass Assembly Air Shutter SettingGrilles and Trim Operating Instructions Before Lighting ApplianceThis appliance has an Intellifire ignition system Final inspection by Lighting Appliance IPI IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsModel Cerona-36 Model Cerona-42 DVP vent components Vent Components DiagramsDVP-TRAP COOL-ADD Not for use with these models Log Set Assembly Service PartsPart number list on following At Depot Service Parts ListStocked IPI Valve AssemblyCERONA-42 Fan Kit GFK-160A Junction Box 4021-013 Box Paint Kit CERONA-42IPI Valve Assembly Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information