VENTING INSTALLATION
Continued
Horizontal Termination Configurations
Figures 29 through 31 show different configurations for venting with horizontal termination. Each figure includes a chart with vertical minimum/maximum and horizontal maximum dimensions which must be met. Seal all connections with high temperature silicone sealant (outer pipe only) as specified in the second warning statement on page 12. All horizontal piping runs require 1/4" rise per 12" of horizontal run.
Horizontal Venting
Vertical (V) Horizontal (H)
52" min. | 26" max. |
63" min. | 49" max. |
86" min. | 96" max. |
91" min. | 20' max. |
.
VENTING INSTALLATION
Installation for Horizontal Termination (Cont.)
Venting with Two 90° Elbows
Vertical (V) | Horizontal (H1) | Horizontal (H1) + |
6' min. | 4' max. | Horizontal (H2) |
8' max. | ||
7' min. | 6' max. | 12' max. |
8' min. | 8' min. | 20' max. |
20' max. | 8' max. | 20' max. |
15
Figure 30 - Horizontal Termination Configuration for Venting
Using Two 90° Elbows Figure 29 - Horizontal Termination Configuration for Venting
Using One 90° Elbow
Venting with Two 90° Elbows
Vertical (V) | Horizontal (H1) + |
| Horizontal (H2) |
6' min. | 4' max. |
7' min. | 6' max. |
8' min. | 10' max. |
20' max. | 12' max. |
Figure 31 - Horizontal Termination Configuration for Venting
Using Two 90° Elbows with Termination at 90° with Stove
For morevisit www..com