Desa SDVBNC PRE-INSTALLATION Preparation, Cast Iron Stove and DIRECT-VENT Burner System Assembly

Page 5

PRE-INSTALLATION PREPARATION

Location and Space Requirements (Cont.)

CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY

Stove Body Assembly

5

PRE-INSTALLATION

PREPARATION

Continued

3. Proper clearances must be maintained, see Figures 3 and 4.

4. This stove is a freestanding unit designed to set directly on the

 

 

 

 

 

 

 

 

floor. If your stove is to be installed directly on carpeting, vi-

 

 

 

 

nyl tile, or any combustible material other than wood, it must

 

 

 

 

be installed on a metal or wood panel extending the full width

 

 

 

 

19 1/2"

 

and depth of the stove. See Figure 5.

 

 

 

 

 

Ceiling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26 1/4"

Front

42"

36"

from

Front

4"

from

Back 27" Wall

Figure 5 - Stove With Burner System Bottom Dimensions

CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY

STOVE BODY ASSEMBLY

1.

Lift off corrugated box enclosing stove body crating.

2.

Remove all screws fastening the wood frame enclosure. Spread

 

wood frame open and lift away from plastic-bagged stove body.

 

The bottom pieces of pallet wood will remain bolted to the

Floor

29"

4"

6"

Front

Figure 3 - Clearances for Standard Installation

 

stove body.

3.

Remove plastic bag from stove body.

4.

Locate the product identification label on the back panel (see

 

Figure 6) and record the model number and 7 digit serial num-

 

ber in the space provided in the back of this owner’s manual.

 

Retain this operation and installation manual for future refer-

 

ence and warranty.

5.

Remove the six (6) bolts on the back stove panel with an ad-

 

justable wrench or a 10 mm socket. Discard the back panel

 

and retain the bolts and washers to attach the rear cover pro-

 

vided with the burner system.

 

 

 

 

 

 

 

 

 

 

 

 

4"

Bolt

4"

Back Stove

Panel

 

Product

Identification

Label

Figure 4 - Clearance for Corner Installation

Figure 6 - Removing Back Panel

For morevisit www..com

107304-01D

Image 5
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Safety Information Table of ContentsON/OFF Product IdentificationGlossary of Terms PRE-INSTALLATION Preparation Product FeaturesLocal Codes Stove Body Assembly PRE-INSTALLATION PreparationCast Iron Stove and DIRECT-VENT Burner System Assembly Removing Pallet Wood From The Bottom of The Stove Attaching Lower Stove Door Panel Installing Optional Blower Accessory Installing the Blower Installing DIRECT-VENT Burner System Into Stove BodySecurely in place before venting pipes are installed Installing Rear CoverLocation of Vent Termination General VentingGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a Chase Installation for Horizontal TerminationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Cathedral Ceiling InstallationVenting with Two Elbows Parts Lists for Venting Kits and Components High Altitude InstallationInstalling GAS Piping to STOVE/ Burner System Location Stove and DIRECT-VENT Burner System InstallationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting STOVE/BURNER System to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Burner System Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver and 9-volt Alkaline Battery Installing Optional Wall Mounted Thermostat GWMT1REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Log No Installing Log No Installing LOGS, Lava Rock and Glowing EmbersOperating Stove with Burner System For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceOptional Remote Operation Manual Lighting ProcedureThermostat Control Operation Ghrcta Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram SpecificationsReplacement Parts Parts Under WarrantySdvbnc Sdvbpc Illustrated Parts BreakdownKEY Sdvbnc Sdvbpc Description QTY Parts ListIndicates Color Suffix Designation Amity Stove Chassis SCIVFC* Series PSCIVFC* SeriesKEY Part Description QTY Accessories Technical ServiceService Hints Owners Registration Form Postage Required 107304-01D Warranty Information