Desa SDVBNC, SDVBPC installation manual Product Identification, On/Off

Page 3

SAFETY INFORMATION PRODUCT IDENTIFICATION

3

SAFETY INFORMATION

Continued

6.Carefully supervise young children when they are in the room with stove.

7.Do not modify the burner or stove under any circumstances. Any parts removed for servicing must be replaced prior to operating stove or burner system.

8.Turn burner system off and let cool before servicing, install- ing, or repairing. Only a qualified service person should in- stall, service, or repair the stove or burner system. Have burner system inspected annually by a qualified service person.

9.You must keep control compartments, burners, and circulat- ing air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding mate- rial, pet hair, etc. Turn off the gas valve and pilot light before cleaning stove or burner system.

10.Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 29.

11.Keep the area around your stove clear of combustible materi- als, gasoline, and other flammable vapor and liquids. Do not run burner system where these are used or stored. Do not place items such as clothing or decorations on or around stove.

12.Do not use this stove to cook food or burn paper or other objects.

13.Never place anything on top of stove.

14.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this stove. Use only the gas type indicated on burner system nameplate.

15.This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Ca- nadian Electrical Code, CSA C22.1.

16.Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around air openings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation.

17.Do not install stove directly on carpeting, vinyl tile, or any com- bustible material other than wood. The stove must set on a metal or wood panel extending the full width and depth of the stove.

18.Do not use stove or burner system if any part has been ex- posed to or under water. Immediately call a qualified service person to arrange for replacement of the unit.

19.Do not operate burner system if any log is broken.

20.Do not use a blower insert, heat exchanger insert, or other ac- cessory not approved for use with this stove.

21.Do not operate burner system with glass door removed, cracked, or broken.

22.Provide adequate clearances to air openings.

PRODUCT IDENTIFICATION

Cast Iron

Stove Body

Log Set

 

OT

O

 

IN

OUT

Piezo Ignitor

Control Valve

Vent

Cast Iron

Stove Body

Opening

 

Rear

 

Cover

 

ON/OFF

 

Switch

 

(Other

 

Side)

 

Pilot

Burner

Glass

Assy

 

Door Assy

Blower with

Lava Rock

Adjustment

 

Knob (Optional

 

Installation)

 

Glowing

Grate Assembly

Embers

 

Figure 1 - DESA Direct-Vent Burner System Shown Installed in Approved Cast Iron Stove Body (Vanguard Models SCIVFC/ PSCIVFC Series Shown)

For morevisit www..com

107304-01D

Image 3
Contents OWNER’S Operation and Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsON/OFF Product IdentificationPRE-INSTALLATION Preparation Product Features Local CodesGlossary of Terms PRE-INSTALLATION Preparation Cast Iron Stove and DIRECT-VENT Burner System AssemblyStove Body Assembly Removing Pallet Wood From The Bottom of The Stove Attaching Lower Stove Door Panel Installing Optional Blower Accessory Installing the Blower Installing DIRECT-VENT Burner System Into Stove BodySecurely in place before venting pipes are installed Installing Rear CoverLocation of Vent Termination General VentingGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a Chase Installation for Horizontal TerminationInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Cathedral Ceiling InstallationVenting with Two Elbows Parts Lists for Venting Kits and Components High Altitude InstallationCheck GAS Type Stove and DIRECT-VENT Burner System InstallationInstalling GAS Piping to STOVE/ Burner System Location Installation Items NeededConnecting STOVE/BURNER System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Burner System Gas Connections Installing Optional Wall Mount Switch GWMS2Installing Remote Receiver and 9-volt Alkaline Battery Installing Optional Wall Mounted Thermostat GWMT1REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Log No Installing Log No Installing LOGS, Lava Rock and Glowing EmbersTo Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Stove with Burner System Lighting InstructionsGhrcta Series Operation Manual Lighting ProcedureOptional Remote Operation Thermostat Control OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Parts Under Warranty SpecificationsWiring Diagram Replacement PartsSdvbnc Sdvbpc Illustrated Parts BreakdownKEY Sdvbnc Sdvbpc Description QTY Parts ListIndicates Color Suffix Designation Amity Stove Chassis SCIVFC* Series PSCIVFC* SeriesKEY Part Description QTY Technical Service Service HintsAccessories Owners Registration Form Postage Required 107304-01D Warranty Information