OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor. Nut is located behind the mounting bracket

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace pilot assembly

7.Replace pilot assembly

When ignitor button is pressed, there is spark at pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Gas control knob not in PILOT position

3.Gas control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP only)

6.Pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn gas control knob to PILOT position

3.Press in gas control knob while in PILOT position

4.Continue holding down gas control knob. Repeat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean pilot (see Cleaning and Mainte- nance, page 29) or replace pilot assembly

7.Replace gas control

Pilot lights but flame goes out when control knob is released

1.Gas control knob not fully pressed in

2.Gas control knob not pressed in long enough

3.Equipment shutoff valve not fully open

4.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged pilot

5.Thermocouple connection loose at con- trol valve

6.Thermocouple damaged

7.Control valve damaged

1.Press in gas control knob fully

2.After pilot lights, keep gas control knob pressed in 30 seconds

3.Fully open equipment shutoff valve

4.A) Contact local gas company

B)Clean pilot (see Cleaning and Maintenance, page 29) or replace pilot assembly

5.Hand tighten until snug, then tighten 1/4 turn more

6.Replace pilot assembly

7.Replace control valve

For..com

107304-01D

Image 30
Contents OWNER’S Operation and Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification ON/OFFPRE-INSTALLATION Preparation Product Features Local CodesGlossary of Terms PRE-INSTALLATION Preparation Cast Iron Stove and DIRECT-VENT Burner System AssemblyStove Body Assembly Removing Pallet Wood From The Bottom of The Stove Attaching Lower Stove Door Panel Installing DIRECT-VENT Burner System Into Stove Body Installing Optional Blower Accessory Installing the BlowerInstalling Rear Cover Securely in place before venting pipes are installedGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installation for Horizontal Termination Installing Vent System in a ChaseInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination ConfigurationsVenting with Two Elbows High Altitude Installation Parts Lists for Venting Kits and ComponentsInstallation Items Needed Stove and DIRECT-VENT Burner System InstallationInstalling GAS Piping to STOVE/ Burner System Location Check GAS TypeConnecting STOVE/BURNER System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Optional Wall Mount Switch GWMS2 Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mounted Thermostat GWMT1 Installing Remote Receiver and 9-volt Alkaline BatteryInstalling Remote Receiver REMOVING/REPLACING Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Log No Installing Log NoLighting Instructions For Your Safety Read Before LightingOperating Stove with Burner System To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureOptional Remote Operation Ghrcta Series OperationInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts SpecificationsWiring Diagram Parts Under WarrantyIllustrated Parts Breakdown Sdvbnc SdvbpcParts List KEY Sdvbnc Sdvbpc Description QTYAmity Stove Chassis SCIVFC* Series PSCIVFC* Series Indicates Color Suffix DesignationKEY Part Description QTY Technical Service Service HintsAccessories Owners Registration Form Postage Required 107304-01D Warranty Information