Desa SDVBPC, SDVBNC installation manual Gas leak. See Warning statement

Page 32

32

TROUBLESHOOTING

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating burner system where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner system produces unwanted odors

1. Gas leak. See Warning statement

 

above

1.Locate and correct all leaks (see Check- ing Gas Connections, pages 21 and 22)

Burner system shuts off in use

1.

High or gusting winds

1.

Burner system has been tested for up to

 

 

 

 

40mph winds. However, extreme con-

 

 

 

 

ditions may occur. See Lighting Instruc-

 

 

 

 

tions on page 26

 

2.

Low line pressure

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Pilot is partially clogged

3.

Clean pilot (see Cleaning and Mainte-

 

 

 

 

nance, page 29)

 

4.

Inner vent pipe leaking exhaust gasses

4.

Locate and correct all leaks in venting

 

 

into system

 

pipe

 

5.

Glass too loose and air tight gasket leaks

5.

Tighten glass door

 

 

in corners after usage

 

 

 

6.

Bad thermopile or thermocouple

6.

Replace faulty component

 

7.

Improper vent cap installation

7.

Check for proper installation and free-

 

 

 

 

dom from debris or blockage

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

above

 

ing Gas Connections, pages 21 and 22)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1. Gas leak. See Warning statement

 

above

1.Locate and correct all leaks (see Check- ing Gas Connections, pages 21 and 22)

Dark residue on logs or inside of burner

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

system

 

 

 

Lava Rock, and Glowing Embers, page 25)

 

2.

Air holes at burner inlet blocked

2.

Clean out air holes at burner inlets. Pe-

 

 

 

 

riodically repeat as needed

 

3.

Burner flame holes blocked

3.

Remove blockage

 

4.

Improper vent configuration

4.

Follow vent configuration instructions

 

 

 

 

in owner’s manual

For..com

107304-01D

Image 32
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Table of Contents Safety InformationProduct Identification ON/OFFGlossary of Terms PRE-INSTALLATION Preparation Product FeaturesLocal Codes Stove Body Assembly PRE-INSTALLATION PreparationCast Iron Stove and DIRECT-VENT Burner System Assembly Removing Pallet Wood From The Bottom of The Stove Attaching Lower Stove Door Panel Installing DIRECT-VENT Burner System Into Stove Body Installing Optional Blower Accessory Installing the BlowerInstalling Rear Cover Securely in place before venting pipes are installedGeneral Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installation for Horizontal Termination Installing Vent System in a ChaseInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination ConfigurationsVenting with Two Elbows High Altitude Installation Parts Lists for Venting Kits and ComponentsStove and DIRECT-VENT Burner System Installation Installing GAS Piping to STOVE/ Burner System LocationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting STOVE/BURNER System to GAS SupplyPressure Testing Gas Supply Piping System Installing Optional Wall Mount Switch GWMS2 Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mounted Thermostat GWMT1 Installing Remote Receiver and 9-volt Alkaline BatteryInstalling Remote Receiver REMOVING/REPLACING Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Log No Installing Log NoFor Your Safety Read Before Lighting Operating Stove with Burner SystemLighting Instructions To Turn OFF GAS To ApplianceManual Lighting Procedure Optional Remote OperationThermostat Control Operation Ghrcta Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Specifications Wiring DiagramReplacement Parts Parts Under WarrantyIllustrated Parts Breakdown Sdvbnc SdvbpcParts List KEY Sdvbnc Sdvbpc Description QTYAmity Stove Chassis SCIVFC* Series PSCIVFC* Series Indicates Color Suffix DesignationKEY Part Description QTY Accessories Technical ServiceService Hints Owners Registration Form Postage Required 107304-01D Warranty Information