Desa SDVBPC, SDVBNC installation manual Installing Optional Wall Mount Switch GWMS2

Page 22

22

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Checking Gas Connection (Cont.)

Installing Optional Wall Mount Switch - GWMS2

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Continued

3.Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 44 for propane/LP or Figure 45 for natural). Apply noncorrosive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Burner System Gas Connections

1.

Open equipment shutoff valve (see Figure 43, page 21).

2.

Open propane/LP supply tank valve for propane/LP burner

 

system or main gas valve located on or near gas meter for natu-

 

ral gas burner system.

3.

Make sure control knob of burner system is in the OFF position.

4.

Check all joints from equipment shutoff valve to thermostat

 

gas valve (see Figure 44 for propane/LP or Figure 45 for natu-

 

ral). Apply noncorrosive leak detection solution to all gas joints.

Gas Valve

Equipment

Shutoff

Valve

Gas Meter

 

Bubbles forming show a leak. Correct all leaks at once.

5.

Light burner system (see Operating Stove with Burner System,

 

pages 26 through 28). Check all other internal joints for leaks.

6.

Turn off burner system (see To Turn Off Gas to Appliance,

 

page 26).

Equipment

 

Shutoff

Propane/LP

Valve

Supply Tank

Gas Valve

 

Figure 44 - Checking Gas Joints for Propane/LP Gas Burner System

Figure 45 - Checking Gas Joints for Natural Gas Burner System

INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2

1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 46. If wires are not connected as shown the switch will not work.

2.Route the 25 ft. wire through openings provided on the sides of the burner system to a convenient location to mount your switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install the wall switch and cover in the wall.

To Control

Switch or

Optional

Accessory

TPTH TP TH

Figure 46 - Control Valve Terminals

For..com

107304-01D

Image 22
Contents For Your Safety OWNER’S Operation and Installation ManualFor Your Safety What to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification ON/OFFLocal Codes PRE-INSTALLATION Preparation Product FeaturesGlossary of Terms Cast Iron Stove and DIRECT-VENT Burner System Assembly PRE-INSTALLATION PreparationStove Body Assembly Removing Pallet Wood From The Bottom of The Stove Attaching Lower Stove Door Panel Installing DIRECT-VENT Burner System Into Stove Body Installing Optional Blower Accessory Installing the BlowerInstalling Rear Cover Securely in place before venting pipes are installedGeneral Venting Location of Vent TerminationGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installation for Horizontal Termination Installing Vent System in a ChaseInstalling Horizontal Vent Cap Noncombustible Exterior Horizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Vertical Termination ConfigurationsVenting with Two Elbows High Altitude Installation Parts Lists for Venting Kits and ComponentsInstallation Items Needed Stove and DIRECT-VENT Burner System InstallationInstalling GAS Piping to STOVE/ Burner System Location Check GAS TypePressure Testing Gas Supply Piping System Connecting STOVE/BURNER System to GAS SupplyChecking GAS Connections Installing Optional Wall Mount Switch GWMS2 Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mounted Thermostat GWMT1 Installing Remote Receiver and 9-volt Alkaline BatteryInstalling Remote Receiver REMOVING/REPLACING Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Log No Installing Log NoLighting Instructions For Your Safety Read Before LightingOperating Stove with Burner System To Turn OFF GAS To ApplianceThermostat Control Operation Manual Lighting ProcedureOptional Remote Operation Ghrcta Series OperationInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts SpecificationsWiring Diagram Parts Under WarrantyIllustrated Parts Breakdown Sdvbnc SdvbpcParts List KEY Sdvbnc Sdvbpc Description QTYAmity Stove Chassis SCIVFC* Series PSCIVFC* Series Indicates Color Suffix DesignationKEY Part Description QTY Service Hints Technical ServiceAccessories Owners Registration Form Postage Required 107304-01D Warranty Information