5.2 Connection onto an existing chimney
You can connect the appliance onto an existing chimney. The existing chimney then functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm performs the flue function. Any existing chimney used as an air supply must only service this appliance.
Requirements:
-300 mm of free space above the appliance;
-The chimney only supply’s air to this appliance;
-The existing chimney needs to be clean and very well swept;
-The existing chimney needs to be airtight;
-The existing chimney needs to have an opening of min. 150 x 150 mm.
|
| Parts needed for this kind of installation: | |
|
| - Chimney connection set |
|
B |
| part number A9225000 | Fig 20 part D |
| - Short roof terminal |
| |
|
|
| |
A |
| part number A9266100 | Fig 19 part B |
| - Chimney closure plate |
| |
|
|
| |
|
| part number A 9240000 | Fig 19 part A |
C |
| - Two stainless steel tubes one 100 mm - | |
|
| length 500 mm and one 150 mm - | |
|
| length 500 mm |
|
|
| part number A 9273900 | Fig 19 part E and F |
|
| 1. Place the aluminium closure plate (A) onto the | |
D |
| chimney. Permanently attach and make airtight. | |
F |
| 2. Pull the liner (C) through the chimney. | |
E |
| 3. Connect the liner onto the roof terminal and fix | |
|
| ||
|
| this with the clamp provided with the chimney | |
|
| connection set. |
|
| fig. 20 | 4. Place the roof terminal onto the closure plate. | |
|
|
|
UK/IRL
5.2Connection onto an existing chimney (continuing)
5.Fixing the chimney sealing plate (D) and place the 150 mm grommet into the hole of the sealing plate.
6.Fix the sealing plate air tight into the builders opening (use the isolation rope from the chimney connection set to make the plate air tight).
7.Slide the pipe (E) 150mm length 500mm into the sealing plate. Slide this pipe so far that you will have enough space later on for assembling the liner.
8.Install the appliance.
9.Connect the flexible stainless steel liner onto the appliance using the 100mm pipe (F) as adapter.
10.If the distance from the flue outlet to the sealing plate is bigger then 300 mm, you have to use a concentric pipe first.
11.Slide the outside pipe onto the appliance or concentric extension so that you have a air tight connection.
28 |
|
|