Faber WHISPER, SILENCE Table Silence and Feeling with interior Widescreen, Number is size in mm

Page 7

UK/IRL

Example calculation 1

Calculati0n horizontal extension fig. 2a:

Flue lenght

C + E = 1m + 1m

2 m

Elbows

D

= 2m

2 m

Total horizontal extension

4 m

Measure or calculate effective height (Hvert)

Flue lenght A

1

m

Roof mounted terinal

1

m

Total effective height

2 m

When calculating on basis of the Widescreen table nr. 2:

It is allowed.

Remove the flue restrictor!

When calculating on basis of the MV100 table nr. 3:

Allowed but without flue restrictor. Remove the flue restrictor!

When calculating on basis of the MV150 table nr. 4:

Allowed but without flue restrictor. Remove the flue restrictor!

When calculating on basis of the Roundscreen table nr. 5:

Allowed but without flue restrictor. Remove the flue restrictor!

Example calculation 2

Calculati0n horizontal extension fig. 2b:

Hvert.

G

F

B

C

E

D

 

 

A

 

 

fig. 2a

UK/IRL

Table Silence and Feeling with interior Widescreen

Determine according to the table 2 the right total horizontal- and vertical length. When meeting an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.

Horizontal extension

 

 

0

1

2

3

4

5

6

 

 

 

0

X

X

X

X

X

X

X

 

 

 

1

0

0

X

X

X

X

X

X

combination

 

1,5

0

0

0

0

X

X

X

 

 

not allowed

 

2

30

30

0

0

0

0

0

 

 

0

remove flue restrictor

height

3

45

45

30

30

0

0

0

 

Number is size in mm

4

45

45

30

30

30

0

0

 

 

 

Effective

5

50

50

45

30

30

30

0

 

of the flue restrictor

8

60

60

60

50

50

X

X

 

 

 

6

50

50

45

30

30

30

0

 

 

 

7

60

60

50

45

45

30

X

 

 

 

9

65

65

60

60

X

X

X

 

 

 

10

65

65

65

X

X

X

X

 

 

 

11

65

65

X

X

X

X

X

table 2

 

12

65

X

X

X

X

X

X

interior Widescreen

Table Whisper and Spectra Nova with interior MV100

Determine according to the table 3 the right total horizontal- and vertical length. When meeting an X, and when the values are outside the table, the combination is not allowed. Normally the 30 mm flue restrictor is preinstalled.

Flue lenght

J + L = 0,5

+ 0,5

1 m

Elbows

K + M = 2m

+ 2m

4 m

Terminal

 

 

1 m

Total horizontal extension

 

6 m

Vertical

 

 

 

Flue lenght

H

 

1 m

When calculating on basis of the Widescreen table nr. 2: Combination not allowed.

Hvert.

L

I J K

M

N

Horizontal extension

 

 

0

1

2

3

4

5

6

 

 

 

0

X

X

X

X

X

X

X

 

 

 

1

30

0

0

0

0

0

0/X*

X

combination

 

2

30

30

0

0

0

0

0

 

not allowed

height

3

45

45

30

0

0

0

0

0

remove flue restrictor

4

45

45

30

0

0

0

0

 

Number is size in mm

5

50

50

45

45

30

0

0

 

 

of the flue restrictor

6

50

50

45

45

30

0

0

 

 

 

 

7

60

60

60

50

50

45

 

 

 

When calculating on basis of the MV100 table nr. 3:

Allowed but without flue restrictor. Remove the flue restrictor!

When calculating on basis of the MV150 table nr. 4:

Combination not allowed.

When calculating on basis of the Roundscreen table nr. 5: Combination not allowed.

H

Effective

8

60

60

60

60

50

 

X

 

X

X

 

9

65

65

60

60

X

X

X

 

 

10

65

65

65

X

X

X

X

 

 

11

65

65

X

X

X

X

X

table 3

 

12

65

X

X

X

X

X

X

interior MV100

* at propane not allowed

10

fig. 2b

11

Image 7
Contents Silence Feeling Whisper Spectra Nova Cadra Nova Misty UK/IRL ContentsIntroduction General safetyPlease leave these instructions with the user Builders opening and surround Installation RequirementsCadra Misty Nova Feeling Silence WhisperFlue restrictor Flue requirementsTable Whisper and Spectra Nova with interior MV100 Table Silence and Feeling with interior WidescreenNumber is size in mm Misty with roundscreen Table Cadra Nova with interior MV150Flue requirements continuing Terminal position Terminal position Flue terminal positionsGas connection Instructions for InstallationUsing an existing chimney as air inlet Example of how terminal position is measuredPreparing the appliances Widescreen and Whisper continuing CCCPreparing the appliance Misty Preparing the appliances Spectra Nova/Cadra Nova continuing Preparing the appliances Spectra Nova/Cadra NovaFitting the firebox continuing Fitting the fireboxPlacing the log set Installation of the FlueConnections with use of concentric duct material Connection onto an existing chimney continuing Connection onto an existing chimneyInstallation remote control Remote control if applicableSetting the right transmission code Functional balanced flue check Commissioning functional checksCheck pilot ignition Functional burner checkServicing Handing OverFinal check and customer briefing Pilot/thermocouple assembly Cleaning the glassCleaning the combustion chamber and burner Burner tray assemblyGas control block Combustion testPart CompanyMV100 Whisper and Spectra Nova User Guide General safety instructions Safety Instructions for the UserKnob B Controlling the ApplianceLighting the fire Knob aRemote control version When the pilot extinguishesTo extinguish Changing the batteries Remote controlCleaning and Service Instructions