UK/IRL
8.1.1 Cleaning the glass
Depending on the intensity of use, you can get a deposit on the glass. This can be removed with a special ceramic glass cleaner (ceramic
1.Remove the front and the back.
2.Clean the glass. Handle the glass with clean hands, wear gloves if possible.
3.To fit the glass, proceed in reverse order. Make sure that the log set has been installed correctly before fixing the glass.
Attention:
Before placing the glass: check the glass sealing rope is in good condition and makes an effective seal. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in). Place the glass in front of the appliance and fix the glass frame or use the glass clamps.
8.1.2 Cleaning the combustion chamber and burner
You can clean the combustion chamber with a vacuum cleaner.
If the burner is visibly damaged, this can affect the distribution of the flame, if so then replace the burner.
8.1.3 Propane conversion
For conversion from propane to natural gas, order for a propane burner unit.
Please give the serial number from the data plate when you order.
UK/IRL
8.1.4Burner tray assembly
1.Remove the front, glass, log set, grid and burner tray cover.
2.Break the gas supply at the control valve.
3.Unscrew the burner assembly and take them out of the combustion chamber.
B
A
D
C
E
F
fig. 25
A.Pilot assembly
B.Burner
C.Fixation plate
D.Injector
E.Gas control
F.Receiver
8.1.5 Pilot/thermocouple assembly
Remove the burner tray as described above.
Now you have access to all the pilot and thermocouple parts.
36 |
|
|
|
|