Faber SILENCE, WHISPER Controlling the Appliance, Lighting the fire, Knob a, Knob B, To light

Page 26

UK/IRL

 

 

 

UK/IRL

10. CONTROLLING THE APPLIANCE

10.1 Lighting the fire

If the main burner or pilot light are extinguished for any reason, do not attempt to relight the pilot within 5 minutes. Contact a qualified installer when the appliance goes off regularly.

The control valve is behind the ashtray door.

Silence /Feeling /Whisper

Open the ashtray door by pushing on the right side for the

Silence/Feeling and on the left side for the Whisper.

Misty

Open the ashtray door by pulling down (bottom handle with gas damper).

Cadra Nova and Spectra Nova

Open by pushing the lip located on the right side in the gap between the ashtray door and the frame (door flaps open).

AB

fig. 27 control unit

With control button A you can light the pilot. With the control button B you can adjust the height of the flames (see fig. 27).

Knob A

The { is the OFF position preventing any gas from passing through the control valve to either the pilot burner or to the main burner. By pressing the knob in it is possible to turn it anticlockwise. The first function is to turn on the gas to the pilot- this occurs just before reaching the position (if the fire has not been lit for some time it may be necessary to hold the knob in this position for some seconds to clear the air from the pipe and allow gas to reach the pilot burner). Once gas is available at the pilot, continued rotation anti-clockwise will cause the piezo igniter to spark. This is accompanied by a click at the valve and should result in the pilot burner igniting. Once the pilot is lit, the control knob should be held pressed in for 10 seconds. In this time the pilot flame will have heated the flame supervision thermocouple sufficiently to operate a hold- on magnet within the valve. Now turn the control knob A to the

position. This allows gas to enter control knob B.

Knob B

The { is the OFF position preventing gas entering the main burner if the pilot is lit. The knob should be turned slowly anticlockwise. This allows gas to enter the burner and be ignited by the pilot flame. Once ignition has taken place, the fire may be set to any level between min. and max. by adjusting the control knob B.

10.2 To light

1.Push in and turn the control knob (A) from { anticlockwise to the setting (small flame). You will hear a ignition click. Check that the pilot is lit (if not repeat).

2.Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable.

3.Release the knob. The pilot should remain alight.

4.Turn the control knob A to the position.

5.Turn knob B slowly anticlockwise, the fire should then ignite.

6.Adjust flames to the required level.

48

 

 

 

49

 

 

Image 26
Contents Silence Feeling Whisper Spectra Nova Cadra Nova Misty Contents UK/IRLPlease leave these instructions with the user General safetyIntroduction Installation Requirements Builders opening and surroundFeeling Silence Whisper Cadra Misty NovaFlue requirements Flue restrictorNumber is size in mm Table Silence and Feeling with interior WidescreenTable Whisper and Spectra Nova with interior MV100 Flue requirements continuing Terminal position Table Cadra Nova with interior MV150Misty with roundscreen Flue terminal positions Terminal positionExample of how terminal position is measured Instructions for InstallationUsing an existing chimney as air inlet Gas connectionCCC Preparing the appliances Widescreen and Whisper continuingPreparing the appliance Misty Preparing the appliances Spectra Nova/Cadra Nova Preparing the appliances Spectra Nova/Cadra Nova continuingFitting the firebox Fitting the firebox continuingConnections with use of concentric duct material Installation of the FluePlacing the log set Connection onto an existing chimney Connection onto an existing chimney continuingSetting the right transmission code Remote control if applicableInstallation remote control Functional burner check Commissioning functional checksCheck pilot ignition Functional balanced flue checkFinal check and customer briefing Handing OverServicing Burner tray assembly Cleaning the glassCleaning the combustion chamber and burner Pilot/thermocouple assemblyCombustion test Gas control blockCompany PartMV100 Whisper and Spectra Nova User Guide Safety Instructions for the User General safety instructionsKnob a Controlling the ApplianceLighting the fire Knob BTo extinguish When the pilot extinguishesRemote control version Remote control Changing the batteriesCleaning and Service Instructions