8.3 TECHNICAL DATA

MV100 Whisper and Spectra Nova

Country

 

UK/IRL

UK/IRL

Category

 

II2H3+

II2H3+

 

 

 

 

Model type

 

C11 0f C31

C11 0f C31

Heat input Hi

kW

7,5

7,5

Efficiency class

 

2

2

NOX class

 

4

4

 

 

 

 

Type of gas

 

G20

G30

Inlet pressure

mbar

20

30/37

Gas rate 15 °C / 1013 mba

m3/h

790

231

 

kg/h

 

540 g

 

 

 

 

Reference burner pressure

mbar

17

22

Injector size

mm

2x 1,40

3x 1,00

 

 

1x 1,30

 

Reduced input restrictor

mm

1,8

1,1

 

 

 

 

Pilot assembly

 

 

 

Type

 

SIT 160

SIT 160

Code

 

Nr 51

Nr 30

 

 

 

 

Flue system

 

 

 

MV size

 

100-150

100-150

Preinstalled flue restrictor

mm

30

30

 

 

 

 

Gas control

 

GV36 with

GV36 without

 

 

pressure reg.

pressure reg.

 

 

 

 

Remote control

 

 

 

Voltage adapter

V

4,5

 

Batteries

 

2x LR03 1,5 V Alkaline

 

 

 

 

Gas connection

mm

8 mm nut

8 mm nut

 

 

and olive

and olive

 

 

 

 

Weight incl packing material

kg

75

75

Dimensions: see table 1

 

 

 

 

 

 

 

UK/IRL

8.3 TECHNICAL DATA

MV150 Cadra Nova

Country

 

UK/IRL

UK/IRL

Category

 

II2H3+

II2H3+

 

 

 

 

Model type

 

C11 0f C31

C11 0f C31

Heat input Hi

kW

7.5

7.5

Efficiency class

 

2

2

NOX class

 

4

4

 

 

 

 

Type of gas

 

G20

G30

Inlet pressure

mbar

20

30/37

Gas rate 15 °C / 1013 mbar

m3/h

800

231

 

kg/h

 

540 g

 

 

 

 

Reference burner pressure

mbar

13

25

Injector size

mm

3x 1.50

3x 0.90

Reduced input restrictor

mm

1.8

1.1

 

 

 

 

Pilot assembly

 

 

 

Type

 

SIT 160

SIT 160

Code

 

Nr 51

Nr 30

 

 

 

 

Flue system

 

 

 

MV size

 

100-150

100-150

Preinstalled flue restrictor

mm

30

30

 

 

 

 

Gas control

 

GV36 with

GV36 without

 

 

pressure reg. pressure reg

 

 

 

 

Remote control

 

 

 

Voltage adapter

V

4,5

 

Batteries

 

2x LR03 1,5 V Alkaline

 

 

 

 

Gas connection

mm

8 mm nut

8 mm nut

 

 

and olive

and olive

 

 

 

 

Weight incl. packing material

kg

75

75

Dimensions: see table 1

 

 

 

 

 

 

 

42

 

 

 

43

 

 

Image 23
Contents Silence Feeling Whisper Spectra Nova Cadra Nova Misty UK/IRL ContentsPlease leave these instructions with the user General safetyIntroduction Builders opening and surround Installation RequirementsCadra Misty Nova Feeling Silence WhisperFlue restrictor Flue requirementsNumber is size in mm Table Silence and Feeling with interior WidescreenTable Whisper and Spectra Nova with interior MV100 Flue requirements continuing Terminal position Table Cadra Nova with interior MV150Misty with roundscreen Terminal position Flue terminal positionsGas connection Instructions for InstallationUsing an existing chimney as air inlet Example of how terminal position is measuredPreparing the appliances Widescreen and Whisper continuing CCCPreparing the appliance Misty Preparing the appliances Spectra Nova/Cadra Nova continuing Preparing the appliances Spectra Nova/Cadra NovaFitting the firebox continuing Fitting the fireboxConnections with use of concentric duct material Installation of the FluePlacing the log set Connection onto an existing chimney continuing Connection onto an existing chimneySetting the right transmission code Remote control if applicableInstallation remote control Functional balanced flue check Commissioning functional checksCheck pilot ignition Functional burner checkFinal check and customer briefing Handing OverServicing Pilot/thermocouple assembly Cleaning the glassCleaning the combustion chamber and burner Burner tray assemblyGas control block Combustion testPart CompanyMV100 Whisper and Spectra Nova User Guide General safety instructions Safety Instructions for the UserKnob B Controlling the ApplianceLighting the fire Knob aTo extinguish When the pilot extinguishesRemote control version Changing the batteries Remote controlCleaning and Service Instructions