Faber CADRA NOVA, SPECTRA NOVA Ccc, Preparing the appliances Widescreen and Whisper continuing

Page 11

UK/IRL

4.2 Preparing the appliances Widescreen and Whisper (continuing)

2.

A

AA

fig. 6

Remove the back panel by loosening the screws B (see fig. 6).

BB

B

B B

fig. 7

3.Remove the glass by removing the glass clamps C (see fig. 7) for instance with a screwdriver. Careful when removing the glass! Wear gloves! Before placing the glass back, be sure that there are no fingerprints on the glass, it is not possible to remove those prints after you burn the appliance or a while (they will be burnt in).

UK/IRL

4.2 Preparing the appliances Widescreen and Whisper (continuing)

CCC

CC

CC

CCC

fig. 8

4.Take the box with the log set out of the combustion chamber.

5.Place the right flue restrictor in the combustion chamber. To determine the right flue restrictor, see chapter 3.

￿

fig. 9

18

 

 

 

19

 

 

Image 11
Contents Silence Feeling Whisper Spectra Nova Cadra Nova Misty UK/IRL ContentsPlease leave these instructions with the user General safetyIntroduction Builders opening and surround Installation RequirementsCadra Misty Nova Feeling Silence WhisperFlue restrictor Flue requirementsNumber is size in mm Table Silence and Feeling with interior WidescreenTable Whisper and Spectra Nova with interior MV100 Flue requirements continuing Terminal position Table Cadra Nova with interior MV150Misty with roundscreen Terminal position Flue terminal positionsGas connection Instructions for InstallationUsing an existing chimney as air inlet Example of how terminal position is measuredPreparing the appliances Widescreen and Whisper continuing CCCPreparing the appliance Misty Preparing the appliances Spectra Nova/Cadra Nova continuing Preparing the appliances Spectra Nova/Cadra NovaFitting the firebox continuing Fitting the fireboxConnections with use of concentric duct material Installation of the FluePlacing the log set Connection onto an existing chimney continuing Connection onto an existing chimneySetting the right transmission code Remote control if applicableInstallation remote control Functional balanced flue check Commissioning functional checksCheck pilot ignition Functional burner checkFinal check and customer briefing Handing OverServicing Pilot/thermocouple assembly Cleaning the glassCleaning the combustion chamber and burner Burner tray assemblyGas control block Combustion testPart CompanyMV100 Whisper and Spectra Nova User Guide General safety instructions Safety Instructions for the UserKnob B Controlling the ApplianceLighting the fire Knob aTo extinguish When the pilot extinguishesRemote control version Changing the batteries Remote controlCleaning and Service Instructions