Faber SPECTRA NOVA, WHISPER, SILENCE, MISTY, FEELING, CADRA NOVA Flue requirements, Flue restrictor

Page 6

UK/IRL

3.2 Flue requirements

The appliance is of the type C11/C31. The appliance will need to be supplied with the approved flue pipes and terminal, it is not possible to supply your own.

The minimum effective height of the flue system must be 0.5 or 1 meter, depending on the appliance.

Terminal locations, through the wall as well as through the roof. See figure 3.

Flue routing;

-a horizontal extension with elbows is allowed for a maximum of 6 meters (depending on the type and situation).

-vertical max. 12 meters.

Determine on the base of the table 2 and 3, depending on the type and terminal position, if the desired situation is possible.

To establish this you will need to calculate:

-The effective height (this is the real difference in height between the upper side of the appliance and the terminal).

-The total horizontal extension. This is the total horizontal flue length where:

each elbow, which is in the horizontal area, counts for 2 meters.

each 45-degree bend, which is in the horizontal area, counts for 1 meter.

elbows and bends at the transition of horizontal to vertically are not to be counted.

the wall mounted terminal counts for 1 meter.

UK/IRL

Flue restrictor

If applicable, in the table is also stated the size of a flue restrictor. This restrictor needs to be fitted in the combustion chamber when placing the appliance ( see chapter 4.2). Normally the smallest flue restrictor is fitted.

8

 

 

 

9

 

 

Image 6
Contents Silence Feeling Whisper Spectra Nova Cadra Nova Misty Contents UK/IRLGeneral safety IntroductionPlease leave these instructions with the user Installation Requirements Builders opening and surroundFeeling Silence Whisper Cadra Misty NovaFlue requirements Flue restrictorTable Silence and Feeling with interior Widescreen Table Whisper and Spectra Nova with interior MV100Number is size in mm Table Cadra Nova with interior MV150 Misty with roundscreenFlue requirements continuing Terminal position Flue terminal positions Terminal positionExample of how terminal position is measured Instructions for InstallationUsing an existing chimney as air inlet Gas connectionCCC Preparing the appliances Widescreen and Whisper continuingPreparing the appliance Misty Preparing the appliances Spectra Nova/Cadra Nova Preparing the appliances Spectra Nova/Cadra Nova continuingFitting the firebox Fitting the firebox continuingInstallation of the Flue Placing the log setConnections with use of concentric duct material Connection onto an existing chimney Connection onto an existing chimney continuingRemote control if applicable Installation remote controlSetting the right transmission code Functional burner check Commissioning functional checksCheck pilot ignition Functional balanced flue checkHanding Over ServicingFinal check and customer briefing Burner tray assembly Cleaning the glassCleaning the combustion chamber and burner Pilot/thermocouple assemblyCombustion test Gas control blockCompany PartMV100 Whisper and Spectra Nova User Guide Safety Instructions for the User General safety instructionsKnob a Controlling the ApplianceLighting the fire Knob BWhen the pilot extinguishes Remote control versionTo extinguish Remote control Changing the batteriesCleaning and Service Instructions