Regency U32-LP4, U32-NG4 installation manual Ground Wire from Kit

Page 16

INSTALLATION

25)Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit.

26)Locate the ground lug.

For P36D-1 / P36-4 Only:

26a) By the receptical box, left of the unit.

For U32-4 Only:

26b) Located on the left side of the unit.

27)Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.

Ground

wire from

kit

28)Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield.

Heat Shield

29)Install the 1/2" bushing to the heat shield.

30)Plug the DC spark generator wires to the DC Sparker.

31)Connect the ground wire to the DC Sparker mounting bracket.

32)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

Battery

Compartment

33)Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit.

34)Find a location which is not too hot and is easy to reach for changing the battery. Note: It should be kept away from the

chain.

Chain

35)Tie up the loose wires with the wire clip.

36)Check for gas leaks.

37)Check inlet and outlet pressures.

38)Check operation of flame control.

39)Check for proper flame appearance and glow on logs.

NOTE: The battery in the DC Sparker Box will need to be replaced an- nually.

16

U32-4 FPI Direct Vent Gas Insert

Image 16
Contents U32 Gas Insert FPI GAS Insert To the NEW OwnerTable of Contents Safety Label Requirements MA Code CO DetectorInstallation Installation Checklist Minimum Fireplace DimensionsManufactured Mobile Home Additional Requirements Materials RequiredVenting Flue Liner InstallationGAS Connection GAS Pipe Pressure Testing GAS Insert Aeration SystemOptional Brick Panel Natural Gas PropaneLOG SET Installation Gas log kit contains the followingRegency Faceplate Trim Installation Rear burnerOptional Double Screen Doors Standard Flush DoorOptional Flush Trim Flush LouversBAY Louvers Optional BAY DoorOptional BAY Trim Removing Bay DoorConversion KIT #514-969 from NG to LP For P36D-1 / P36-4 OnlyInstallation of the DC Sparker Ground Wire from Kit Full Screen Doors Hinge Hampton Cast Faceplate Installation Ensure that Top and sides are AlignedHampton Cast Grill Installation U31 onlyKensington Front Installation Left SideKensington Panel Door Installation Glass Door Sub-Frame HookOptional Remote Control Thermostat Wire TableKensington Optional Wall ThermostatWiring Diagrams Electrical Grounding InstructionsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Maintenance Instructions Copy of Lighting Instruction PlateMaintenance FAN Maintenance Bay Glass RemovalValve Replacement Entrire assembly outInstall a new gasket and reinstall the valve assembly Shut off the gas supplyParts List Main AssemblyBurner Assembly & LOG SET Bay Door Flush Door400-917 Faceplate Assembly402-918 Complete Faceplate Set Hampton Cast Faceplate Assembly 187 189 188 194 203 201 207 195 205U32-4 FPI Direct Vent Gas Insert U32-4 FPI Direct Vent Gas Insert U32-4 FPI Direct Vent Gas Insert Warranty Warranty Limited LifetimeInstaller Please complete the following information