Regency Official Gas Fireplace Manual and Installation Guide

Page 10

INSTALLATION

LOG SET

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)02-43 Rear Log

b)02-45 Front Right Log

c)02-56 Middle Left Log

d)02-46 Left Top Log

e)02-47 Center Log

f)02-48 Middle Right Log

g)02-44 Front Left Log

h)Embers

i)Rockwool

j)Vermiculite

Note: Install Optional Brick Panels prior to installing logs.

The "02" refer numbers (i.e. 02-43) are

molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the vermiculite around the fi rebox base. Take some of the embers (approx. 1/3 of the bag) and sprinkle over the vermiculite.

Vermiculite

Vermiculite

Vermiculite

and embers.

and embers.

and embers.

3) Place Rear Log A)02-43 on the two pins on

6) Place the Left Top Log D)02-46 on the pin

the rear log support.

on Log C)02-56 and on top of the cutout

 

on Log A)02-43.

 

A)02-43

D)02-46

 

 

 

 

 

A)02-43

 

C)02-56

 

Pins on Rear Log Support

Pin

Cutout

4) Place Front Right Log B)02-45 on the two

7) Place the notch in Center Log E)02-47 over

pins as shown.

Log B)02-45 and across the cutout on Log

 

A)02-43.

 

 

E)02-47

A)02-43

 

 

B)02-45

 

 

 

 

B)02-45

5) Place the Middle Left Log C)02-56 on the

Notch

Cutout

two pins as shown.

 

 

C)02-56

Logs D)02-46 and E)02-47 in position.

8) Position notch in Front Right Log F)02-48 on Log E)02-47 and push the bottom right edge against the bracket on the burner tray and the front edge of the rear burner.

F)02-48

Logs A)02-43, C)02-56, and B)02-45 in position

B)02-45

NotchBracket

10

U32-4 FPI Direct Vent Gas Insert

Image 10
Contents U32 Gas Insert FPI GAS Insert To the NEW OwnerTable of Contents Safety Label Requirements MA Code CO DetectorInstallation Manufactured Mobile Home Additional Requirements Installation ChecklistMinimum Fireplace Dimensions Materials RequiredVenting Flue Liner InstallationGAS Connection Optional Brick Panel GAS Pipe Pressure TestingGAS Insert Aeration System Natural Gas PropaneLOG SET Installation Gas log kit contains the followingRegency Faceplate Trim Installation Rear burnerOptional Flush Trim Optional Double Screen DoorsStandard Flush Door Flush LouversOptional BAY Trim BAY LouversOptional BAY Door Removing Bay DoorConversion KIT #514-969 from NG to LP For P36D-1 / P36-4 OnlyInstallation of the DC Sparker Ground Wire from Kit Full Screen Doors Hinge Hampton Cast Faceplate Installation Ensure that Top and sides are AlignedHampton Cast Grill Installation U31 onlyKensington Front Installation Left SideKensington Panel Door Installation Glass Door Sub-Frame HookKensington Optional Remote ControlThermostat Wire Table Optional Wall ThermostatWiring Diagrams Electrical Grounding InstructionsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Maintenance Instructions Copy of Lighting Instruction PlateMaintenance FAN Maintenance Bay Glass RemovalInstall a new gasket and reinstall the valve assembly Valve ReplacementEntrire assembly out Shut off the gas supplyParts List Main AssemblyBurner Assembly & LOG SET Bay Door Flush Door400-917 Faceplate Assembly402-918 Complete Faceplate Set Hampton Cast Faceplate Assembly 187 189 188 194 203 201 207 195 205U32-4 FPI Direct Vent Gas Insert U32-4 FPI Direct Vent Gas Insert U32-4 FPI Direct Vent Gas Insert Warranty Warranty Limited LifetimeInstaller Please complete the following information