Regency U32-LP4, U32-NG4 installation manual Installation

Page 6

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The FPI Gas Insert must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction todeterminetheneedforapermitpriortostarting the installation.

NOTE: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or property damage. Failure to follow these instructions may also void your fi re insurance and/or warranty.

FOR YOUR SAFETY

Thisappliancerequiresairforpropercombustion. Always provide adequate combustion and ventilation air. Follow instructions and information in CAN/CGA B149 (in Canada) or the National Fuel Gas CodeANSI Z223.1 (in the USA), regarding requirements for combustion and ventilation air.

SPECIFICATIONS

At pressures over 1/2 psig, the pipe to the unit must be disconnected.

Gas Input Capacity:

 

Natural Gas

30,000

Btu/h

Propane

30,000

Btu/h

Min. Input

 

 

Natural Gas

15,300

Btu/h

Propane

15,000

Btu/h

Fuels: Approved for use with both natural gas, and propane. Approved as is for use at 0' to 4,500' (0-1370m).

Electrical: 120V A.C. system.

Circulation Fan: Variable speed, 110 CFM.

Log Set: Ceramic fi bre, 7 per set.

Vent System: 3" co-linear aluminum fl ex.

The effi ciency rating of the appliance is a product thermal effi ciency rating determined under continuous operating conditions and was determined independent of any installed

system.

GAS PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than

1/2 psig. (3.45 kPa).

INSTALLATION INTO A SOLID FUEL BURNING FIREPLACE OR FACTORY BUILT FIREPLACE

The U32-4 Gas Inserts have been tested and approvedtobeventedintoanymasonryfireplace or approved solid fuel burning factory built

replace that will allow the insert to physically

t into the fi rebox. Refer to "Minimum Fireplace Dimensions" section for minimum fi replace clearances.

If the factory built fi replace* height is too low for your Insert, you may remove the smoke baffl e plate, damper, refractory (fi rebricks), glass doors, screen rails, screen mesh and log grates from the factory built fi replace as long as these items are saved and are reinstalled in the event that the Insert is removed.

Smoke shelves, shields and baffl es may be removed if attached by mechanical fasteners. If any part is removed it must not weaken the structural integrity of the factory built fi replace.

NOTE: Any alterations made to the listed solid fuel burning factory built fi replace may void the listing of the fi replace.

*Check with your local inspector before commencing with this installation.

Installer must mechanically attach the supplied label to the inside of the fi rebox of the fi replace into which the gas fi replace insert is installed.

"WARNING:This fireplace has been converted for use with a gas fi replace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fi replace re-approved by the authority having jurisdiction."

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

General Safety Information

1)The appliance installation must conform with local codes or in the absence of local codes, with CAN/CGA B149 (in Canada) or the National Fuel Gas Code ANSI Z223.1 in theU.S.A.Thisapplianceshouldbeinstalled by a qualifi ed gas fi tter technician only.

2)Installation and repair should be done by a qualified service person.

3)The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, animal hair, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

4)See general construction and assembly

instructions. This appliance may only be installed in a vented, noncombustible

replace.

5)This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

6)Always connect this insert to a vent system venting to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is properly sized and is of adequate height to provide the proper draft.

7)Inspect the venting system annually for blockage and any signs of deterioration.

8)Any glass removed for servicing must be replaced prior to operating the appliance.

9)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the

replace.

10)Due to high temperatures, the appliance should be located out of high traffi c areas and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures, especially the fi replace glass and gold trims, and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other fl ammable material should not be placed on or near the appliance.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

6

U32-4 FPI Direct Vent Gas Insert

Image 6
Contents U32 Gas Insert FPI GAS Insert To the NEW OwnerTable of Contents Safety Label Requirements MA Code CO DetectorInstallation Manufactured Mobile Home Additional Requirements Installation ChecklistMinimum Fireplace Dimensions Materials RequiredFlue Liner Installation VentingGAS Connection Optional Brick Panel GAS Pipe Pressure TestingGAS Insert Aeration System Natural Gas PropaneLOG SET Installation Gas log kit contains the followingRegency Faceplate Trim Installation Rear burnerOptional Flush Trim Optional Double Screen DoorsStandard Flush Door Flush LouversOptional BAY Trim BAY LouversOptional BAY Door Removing Bay DoorConversion KIT #514-969 from NG to LP For P36D-1 / P36-4 OnlyInstallation of the DC Sparker Ground Wire from Kit Full Screen Doors Hinge Hampton Cast Faceplate Installation Ensure that Top and sides are AlignedHampton Cast Grill Installation U31 onlyKensington Front Installation Left SideKensington Panel Door Installation Glass Door Sub-Frame HookKensington Optional Remote ControlThermostat Wire Table Optional Wall ThermostatWiring Diagrams Electrical Grounding InstructionsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Maintenance Instructions Copy of Lighting Instruction PlateMaintenance FAN Maintenance Bay Glass RemovalInstall a new gasket and reinstall the valve assembly Valve ReplacementEntrire assembly out Shut off the gas supplyParts List Main AssemblyBurner Assembly & LOG SET Bay Door Flush DoorFaceplate Assembly 400-917402-918 Complete Faceplate Set Hampton Cast Faceplate Assembly 187 189 188 194 203 201 207 195 205U32-4 FPI Direct Vent Gas Insert U32-4 FPI Direct Vent Gas Insert U32-4 FPI Direct Vent Gas Insert Warranty Warranty Limited LifetimeInstaller Please complete the following information