Regency U32-NG4, U32-LP4 BAY Louvers, Optional BAY Door, Optional BAY Trim, Removing Bay Door

Page 13

INSTALLATION

2)Install the Spring Hinges on the left and right side of the bottom of the Firebox using 2

screws per hinge.

3) Place the Bottom Louver near the hinge. Flip hinge over the Bottom Louver and secure using 3 screws.

Hinge

Location

SIT Extension knobs for Bay Front only.

BAY LOUVERS

1)Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below.The fitted louver leaves a small gap between faceplate bottom and louver top.

Bottom Louver

OPTIONAL BAY DOOR

The Bay louvers MUST be used

with the Bay glass option.

The optional Bay door is an overlay on the flush front. The standard fl ush door and glass must remain on the unit. Hook the top of the bay door over the fl ush door fl ange and swing the bottom against the bottom fl ange of the fl ush door. Press down on the Bay Bottom bracket and push in until it clips behind the bottom of

Removing Bay Door

ToremoveonlytheBayDoor-useascrewdriver to unclip the Bay Bottom bracket from the fl ush door and then swing up and unhook from the top fl ush door fl ange.

To remove the Bay Door & the Flush Front together, pull the hook from the slot in the bottomdoorbracketundertheunit(seeStandard Flush Door instructions above). Then pull the Bay Door and Flush door out and lift off of the fl ange at the top of the unit.

Note: If any maintenance etc. must be done in the firebox, first remove the Bay louvers and door.

2)Install bottom louver by sliding the two bracket clips into the brackets located underneath the bay door. Secure with 1 screw into each Bottom Louver Mounting Bracket as per diagram below. Use the bottom hole in the bracket.

the fl ush front.

OPTIONAL BAY TRIM

Attach the 4 supplied magnets, each to the back of the top and bottom trim pieces (space out evenly) and attach trim to the top and bot- tom of Bay door.

3) Slide the valve extension knobs onto the valveknobs.Matcheachextensionknobwith the corresponding valve knob. Extension knobs are for Bay Front installations only.

U32-4 FPI Direct Vent Gas Insert

13

Image 13
Contents U32 Gas Insert To the NEW Owner FPI GAS InsertTable of Contents Safety Label MA Code CO Detector RequirementsInstallation Minimum Fireplace Dimensions Installation ChecklistManufactured Mobile Home Additional Requirements Materials RequiredVenting Flue Liner InstallationGAS Connection GAS Insert Aeration System GAS Pipe Pressure TestingOptional Brick Panel Natural Gas PropaneGas log kit contains the following LOG SET InstallationRear burner Regency Faceplate Trim InstallationStandard Flush Door Optional Double Screen DoorsOptional Flush Trim Flush LouversOptional BAY Door BAY LouversOptional BAY Trim Removing Bay DoorFor P36D-1 / P36-4 Only Conversion KIT #514-969 from NG to LPInstallation of the DC Sparker Ground Wire from Kit Full Screen Doors Hinge Ensure that Top and sides are Aligned Hampton Cast Faceplate InstallationU31 only Hampton Cast Grill InstallationLeft Side Kensington Front InstallationGlass Door Sub-Frame Hook Kensington Panel Door InstallationThermostat Wire Table Optional Remote ControlKensington Optional Wall ThermostatElectrical Grounding Instructions Wiring DiagramsFor Propane Units and Units Equipped with DC Spark Boxes Operating Instructions Copy of Lighting Instruction Plate Maintenance InstructionsMaintenance Bay Glass Removal FAN MaintenanceEntrire assembly out Valve ReplacementInstall a new gasket and reinstall the valve assembly Shut off the gas supplyMain Assembly Parts ListBurner Assembly & LOG SET Flush Door Bay Door400-917 Faceplate Assembly402-918 Complete Faceplate Set 187 189 188 194 203 201 207 195 205 Hampton Cast Faceplate AssemblyU32-4 FPI Direct Vent Gas Insert U32-4 FPI Direct Vent Gas Insert U32-4 FPI Direct Vent Gas Insert Warranty Limited Lifetime WarrantyInstaller Please complete the following information