Regency FP90 installation manual FAN Installation, Diagram

Page 22

INSTALLATION

INSTALLATION

FAN INSTALLATION

NOTE: If optional Ashtray is installed, it must be removed before installing the fan.

The receptacle Box must be wired for the fan cable to be plugged into.

1)Remove the thumb screw from the fan transfer tray.

2)Slide fan transfer tray fully out through the bottom louver opening.

3)Mount the fan bracket onto the fan transfer tray using the two locating pins.

4)Slide the Control Box onto the Control Box Mounting Bracket located on the front of the fan transfer tray and secure with

the #8 x 3/8” screw provided (refer to Diagram 1).

Diagram 1

5)Install the wiring as shown on the wiring diagram. Use the strength relief for running the wires from the fan transfer tray to the receptacle box or the ground screw (refer to Diagram 2).

FAN 910-175

AX-3088910-903910-516

GROUND

POWER CORD 910-519

 

 

NEUTRAL - FROM FAN

SWITCH

 

M

M

VARIABLE

GROUND

 

 

 

910-896

- TO

 

F

F

HOT

 

 

 

 

 

M

 

M

811

 

F

 

F

910-

 

 

 

 

F R

 

F R

 

 

THERMODISC 910-142

VARIABLE SWITCH 910-330

60T12

 

Diagram 2

6)Slide the fan transfer tray back into the unit and hook up wires to the Control Box and mount the thermo disc in place.

22

FPI FP90 Wood Fireplace

Image 22
Contents FP90 Wood Fireplace Regency Fireplace Product Table of Contents Safety Label Safety Label for FP90Installation Product DetailsPlease Retain this Manual for Future Reference Dimensions and Specifications Clearances and Height Requirements Installation of Nailing Strips Fireplace Enclosure FramingFraming Details Hearth ExtensionChimney System Considerations Installation ComponentsBefore YOU Start Chase EnclosureInstallation Measurements / Framing Details On EInstalling the Chimney System Assembly StepsInstalling STAND-OFFS SET the Regency FP90 Into PositionOffset Chimney Installation Special NotesInstalling Outside AIR KIT Elevation FT # of Elbows Above SEA LevelGravity AIR Feed KIT Option Wiring the FP90Installing Blower Systems Internal Blower with Thermo-DiscFinishing Regency FP90 Non-self Supporting, Thin Veneer Facades InstallationCompleting The Facing Masonry Retainer Kit Option Finishing Details Completing The MantleGlass Secondary AIR Tube Installation Masonry Liner BricksASH Drawer KIT Ash Drawer Kit InstallationSafety Precautions OptionFAN Installation DiagramMasonry Cover Plate Installation Installation Finishing Trim KIT Installation 60W xAREAStandoff Fireplace Screen Installation Installing the Handles on the ScreenRegency Louver Installation Installing the Top Louver Installing the Bottom LouverExcalibur Faceplate Installation Installing the Facing GuideExcalibur Accent KIT Installation Listings and Code Heatwave KIT not EPA ApprovedGeneral Approvals InformationR90 / EX90 Models InstallationMinimum Framing Clearances All ModelsWiring Diagram MaintenanceOperation Operating Instructions Safety GuidelinesOperating Instructions First FireGlass Removal Replacement MaintenancePlated Finishes Glass Cleaning Door GasketParts List Parts LIST- Firebox & BodyParts LIST- BAFFLES, DOOR, Options FPI FP90 Wood Fireplace Warranty Warranty LifetimeInstaller Please complete the following information