HEATWAVE KIT (NOT EPA APPROVED)
LISTINGS AND CODE | GENERAL |
APPROVALS | INFORMATION |
3) This kit is tested and safe when installed in |
accordance with this installation manual. |
Please read all instructions before starting |
installation and follow all instructions |
This Kit has been approved for use with Models EX90 / R90. This kit has been tested in accordance with National Safety Standards, and has been certifi ed by OMNI Test Laboratories for installation and operation in Canada as described in these Installation and Operating Instructions.
Check with your local building code agency before you begin your installation to ensure compliance with local codes, including the need for "permits" and
The Heat Wave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home.
Up to two kits may be installed on the fireplace. Please Note: Only 1 HeatWave kit may be operated at one time. This includes the internal blower option as well.
Important Installation Notes
1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes,
2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.
carefully during installation. |
4) Installation of this kit must be performed by |
a qualifi ed service technician. |
5) The Heat Wave Kit must be installed only |
as specifi ed. Any modifi cations of the kit or |
components will void the warranty and may |
cause a fi re hazard. |
6) Plan the location of the fireplace and the |
warm air duct runs, see diagram 1 as a |
guide for possible duct runs and locations. |
Maximum Duct Run: 20 ft. (6.1m) per |
kit. |
NOTE: Airfl ow through the duct system is |
affected by the duct length and number of |
bends. Keep the length and bends to a |
minimum to maximize performance. |
HEATWAVE KIT
Included with Kit:
1
1
1
1
1
1
1
1
1
If any parts are missing or damaged, contact your dealer before starting installation. DO NOT install a damaged kit.
PARTS |
Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of
bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit.