Regency FP90 installation manual Excalibur Faceplate Installation, Installing the Facing Guide

Page 29

INSTALLATION

EXCALIBUR FACEPLATE INSTALLATION

NOTE: Before installing the fireplace the facing guide must be installed.

Installing the Facing Guide

1)Secure the left and right facing guides to the fi re- place with seven (7) screws (#10 x 1”) on each side. Holes must be pre-drilled.

2)Install the top louver opening adapter to the face of the unit with fi ve (5) screws (¼-20 x ½”).

3)Attach the sides of the top louver opening adapter to the left and right facing guides with two (2) screws (#8 x ½”).

Installing the Excalibur Faceplate

1)Remove the left and right door from the fi replace.

2)Put the Excalibur faceplate in place and secure with four (4) screws (¼-20 x ½”) making sure that the faceplate is centered.

3)Replace the left and right doors on the hinges.

WARNING: Keep masonry material at least 1/2” (13mm) from this top facing guide. This is required to prevent masonry facing material from hitting the top stiffener located on the back of the surround which is higher than this edge.

INSTALLATION

Optional:

4)Install the optional masonry cover plate to the facing guides with four (4) screws (¼-20 x ½”).

FPI FP90 Wood Fireplace

29

Image 29
Contents FP90 Wood Fireplace Regency Fireplace Product Table of Contents Safety Label for FP90 Safety LabelProduct Details InstallationPlease Retain this Manual for Future Reference Dimensions and Specifications Clearances and Height Requirements Fireplace Enclosure Framing Installation of Nailing StripsHearth Extension Framing DetailsBefore YOU Start Installation ComponentsChimney System Considerations Chase EnclosureOn E Installation Measurements / Framing DetailsInstalling STAND-OFFS Assembly StepsInstalling the Chimney System SET the Regency FP90 Into PositionSpecial Notes Offset Chimney InstallationElevation FT # of Elbows Above SEA Level Installing Outside AIR KITInstalling Blower Systems Wiring the FP90Gravity AIR Feed KIT Option Internal Blower with Thermo-DiscCompleting The Facing Non-self Supporting, Thin Veneer Facades InstallationFinishing Regency FP90 Masonry Retainer Kit Option Completing The Mantle Finishing DetailsMasonry Liner Bricks Glass Secondary AIR Tube InstallationSafety Precautions Ash Drawer Kit InstallationASH Drawer KIT OptionDiagram FAN InstallationMasonry Cover Plate Installation Installation 60W xAREA Finishing Trim KIT InstallationStandoff Installing the Handles on the Screen Fireplace Screen InstallationInstalling the Top Louver Installing the Bottom Louver Regency Louver InstallationInstalling the Facing Guide Excalibur Faceplate InstallationExcalibur Accent KIT Installation General Heatwave KIT not EPA ApprovedListings and Code Approvals InformationMinimum Framing Clearances InstallationR90 / EX90 Models All ModelsOperation MaintenanceWiring Diagram Operating Instructions Safety GuidelinesOperating Instructions First FirePlated Finishes Glass Cleaning MaintenanceGlass Removal Replacement Door GasketParts LIST- Firebox & Body Parts ListParts LIST- BAFFLES, DOOR, Options FPI FP90 Wood Fireplace Warranty Lifetime WarrantyInstaller Please complete the following information