HEATWAVE KIT (NOT EPA APPROVED)
Oval Air Duct: Attach the
Round and Oval Duct: A combination of 6" round and 6" oval duct can be used in the duct run. Oval duct components are not supplied but can be purchased from an HVAC supplier.
4)Install thevariablespeed WallRheostat(with OFF setting) in a convenient location. This switch controls the fan operation.
5)Wire 120V AC service to the Wall Rheostat and from the Wall Rheostat to the Fan Junction Box. Use wire nuts to secure the 120V AC wires to the hot and neutral fan wires and screw the 120V AC ground wire to the Fan Junction Box. See wiring diagram below.
6)Screw the fan junction box to the fan housing.
7)Screw the Register Adapter Frame and the Air Register to the Fan Housing, diagram 4 below.
Note: For new construction only the Air Register is required to cover the opening.
8) Complete the fi replace installation as per fi replace installation manual.
OPERATION
1)Start the fireplace as per instructions and allow it to warm up.
2)Turn the Wall Rheostat "ON" and adjust the variable speed based upon desired air fl ow at the Air Duct Register.
MAINTENANCE
1)Service and maintain the fi replace as per the fi replace installation manual.
2)Keep the Air Register(s) clean and free of any blockage.
HEATWAVE
Diagram 3
Diagram 4
WIRING DIAGRAM
NOTE: The wires (in dotted lines) and wire nuts are supplied by others.
Ground Lug |
| CAUTION: Label all wires prior |
|
| to disconnection when servicing |
Caution: Ensure that the wires do | Do not cut the ground terminal off | controls. Wiring errors can |
not touch any hot surfaces and are | under any circumstances. | cause improper and dangerous |
away from sharp edges. |
| operation. |
|
|
|
IMPORTANT: If the internal blower is installed, it cannot be operated if the Heat Wave air duct kit fan is operating.
KIT
FPI FP90 Wood Fireplace | 33 |