Regency FP90 Maintenance, Plated Finishes Glass Cleaning, Door Gasket, Door Hinges

Page 35

MAINTENANCE

PLATED FINISHES

GLASS CLEANING

CHIMNEY CLEANING

The optional plated fi nishes on the louvers and surrounds requires little maintenance and needs only to be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty. Keep doors and louvers off during construction to avoid damage.

Only clean your glass window when it is cool. Your local retailer can supply you with a recommended glass cleaner if plain water and a soft cloth does not remove all deposits. Do not use oven cleaner on the glass as it will etch the glass.

Do not use any type of abrasive cleaner to clean glass.

Do not permit any creosote or soot build-up in the chimney system. If you detect any build-up contact a qualifi ed chimney sweep or clean it yourself. Perform the following steps:

a.

Remove the fi rst secondary air tube and

 

baffl es.

b.

Removetheterminationcapbyremoving

 

the screws and lifting.

DOOR GASKET

If the door gasket requires replacement, you must use 5/8" (16mm) diameter oval, medium density material, 34"(864mm)longforeachside. A proper high temperature gasket adhesive is required. Contact your dealer for the Regency Gasket Repair Kit.

DOOR HINGES

Grease door hinges with high temperature grease regularly for smooth operation and to avoid squeaks.

GLASS REMOVAL /

REPLACEMENT

Allow the stove to cool before removing or replacing glass. Remove the door from the

replace and remove the glass retainer. Use caution when removing broken glass to avoid injury. When placing the replacement glass in the door, make sure that the glass gasketing will properly seal your unit. Replace the retainer and tighten securely, but do not wrench down on the glass as this may cause breakage. Do not substitute materials. If your glass door breaks, do not use your unit until it has been replaced.

c. Make sure fi replace doors are shut to

 

prevent soot and dirt from entering the

 

loom.

d.

Clean chimney with either nylon or steel

 

brush.

e.

Replace chimney cap.

f.

Re-install baffles and secondary

 

tubes.

MAINTENANCE

FPI FP90 Wood Fireplace

35

Image 35
Contents FP90 Wood Fireplace Regency Fireplace Product Table of Contents Safety Label for FP90 Safety LabelProduct Details InstallationPlease Retain this Manual for Future Reference Dimensions and Specifications Clearances and Height Requirements Fireplace Enclosure Framing Installation of Nailing StripsHearth Extension Framing DetailsChase Enclosure Installation ComponentsBefore YOU Start Chimney System ConsiderationsOn E Installation Measurements / Framing DetailsSET the Regency FP90 Into Position Assembly StepsInstalling STAND-OFFS Installing the Chimney SystemSpecial Notes Offset Chimney InstallationElevation FT # of Elbows Above SEA Level Installing Outside AIR KITInternal Blower with Thermo-Disc Wiring the FP90Installing Blower Systems Gravity AIR Feed KIT OptionCompleting The Facing Non-self Supporting, Thin Veneer Facades InstallationFinishing Regency FP90 Masonry Retainer Kit Option Completing The Mantle Finishing DetailsMasonry Liner Bricks Glass Secondary AIR Tube InstallationOption Ash Drawer Kit InstallationSafety Precautions ASH Drawer KITDiagram FAN InstallationMasonry Cover Plate Installation Installation 60W xAREA Finishing Trim KIT InstallationStandoff Installing the Handles on the Screen Fireplace Screen InstallationInstalling the Top Louver Installing the Bottom Louver Regency Louver InstallationInstalling the Facing Guide Excalibur Faceplate InstallationExcalibur Accent KIT Installation Approvals Information Heatwave KIT not EPA ApprovedGeneral Listings and CodeAll Models InstallationMinimum Framing Clearances R90 / EX90 ModelsOperation MaintenanceWiring Diagram First Fire Safety GuidelinesOperating Instructions Operating InstructionsDoor Gasket MaintenancePlated Finishes Glass Cleaning Glass Removal ReplacementParts LIST- Firebox & Body Parts ListParts LIST- BAFFLES, DOOR, Options FPI FP90 Wood Fireplace Warranty Lifetime WarrantyInstaller Please complete the following information