1 Foreword

1.1 Introduction of Maintenance Tools

The Maintenance Tools are comprised of the On-Line Monitor and the Off-Line Monitor. The following two connection methods are available in the Online Monitoring.

(1)Monitoring by connecting the maintenance tool to MN converter (CMS-MNF) via RS-232C.

(2)Monitoring through the central controller (G-50) by connecting the maintenance tool to LAN. A brief explanation of each of their function is provided here.

*To use the maintenance tool via G-50 (Network), license registration for the G-50 to be used is necessary. Purchasing the license No. for each G-50 to be used, conduct the license registration through the Web browser (http://[IP address of the G-50A]/ administrator.html). After selecting "Maintenance tool" of the optional function on the Web Browser Screen displayed, enter the purchased license No..

For the detail of the license registration, see Chapter 4 [Registering a License for Optional Functions] of Central Controller Model: G-50A Web Browser Operation Manual (For manager).

1.1.1 On-Line Monitor(via MN converter)

The On-Line Monitor is connected to the unit by a MN Converter (CMS-MNF) and can monitor such areas as system data, unit data and operating data.

(1) In case for local connection

Connecting PC installed with the maintenance tool to M-NET transmission line via MN Converter allows conducting various monitoring and setting from the maintenance tool.

RS-232C M-NETM-NET

Maintenance

MN Converter

Tools PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) In case for remote connection

Using a modem and remotely connecting PC installed with the maintenance tool to MN Converter via public telephone circuit allow conducting various monitoring and setting as same in the case of local connection.

Public

network

RS-232C

RS-232C M-NET

MODEM

MODEM MN Converter

Maintenance

 

Tools PC

 

*For the remote connection utilizing MN Converter, an isolator is required to be inserted between the modem and MN Converter.

For detail, please see Installation Manual-annexing of MN Converter (CMS-MNF).

1

Image 2
Contents Mitsubishi Operating ManualOn-Line Monitorvia MN converter Introduction of Maintenance ToolsForeword Case for remote connection Dialup connection mode On-Line Monitorvia G-50Remote access method Wide area access modeImage of the Operation monitor mail communication mode Off-Line MonitorRequired Materials Required Operating EnvironmentHardware Requirements Setting up the database InstallationSetting Up the Maintenance Tools New setup MinutesSetting up the Maintenance Tools Uninstalling the Maintenance Tool Running Maintenance Tool UpgradeEnding the Maintenance Tool Upgrade the DatabaseUninstalling the Maintenance Tools RE Change of computer name on PCWide area access mode Starting the Maintenance ToolNormal mode Starting and Ending the ApplicationCase for remote connection Page Click on Line will be disconnected Starting the On-Line MonitorG-50 connection Case for local connectionCase for remote connection Dialup Next Remote Monitor screen is displayedCase for remote connection E-mail Address book Using the Wide area access mode Starting the Off-Line MonitorCreating the Customer name folder Online ConnectionCreating the Area name folder Above Setting the Air conditioning system nameSetting screen of air conditioning system Setting of Com port Other settingMail setting of maintenance tool PC Offline AnalyzeOpen the Off-line Analyze Screen Ending the Off-Line MonitorOpen the Main Screen Operating Method Terms for Each SectionDesign of Screen On-Line Monitor Operating Method On-Line Monitor Screen TransferAddress Search Method Selection Function ChartAddress Search Method Automatic SearchSearching Screen will appear Automatic SearchingManual Searching Refer to 3.6 Connecting Information 3.6.2 2 Menu Bar Main ScreenScreen Transfer Operation Connecting InformationFunction Selection Operations Items Performed HereClick on Term and Explanation of Terminology Screen appear 4Momentarily, the Connecting Information ScreenScreen Functions and Operation Operation Monitor Message Monitoring! Please wait for a moment. will appearMomentarily, the Operation Status Monitor Screen will appear Screen Functions and Operations 1Operation ButtonsAbout LM Adapter Introduction to the screen Tens digit Trend graph Ending the graph Screen function and operationMalfunction Log Message Monitoring. Please wait for a moment. will appearMessage Close the malfunction log display? will be displayed Optional Setting Self-Diagnosis MonitoringCommand Screen and return to the Optional Setting Screen Sending CommandMonitoring of Pre-error Data Refer to 3.6 Connecting Information 3.6.2 2Menu BarDate / Time Setting Main ScreenOperation Control Screen Functions and Operation Indoor unit, Lossnay unitScreen Functions and OperationBC Controller Monitoring of contact status Free contact of indoor unitStarting of this function Operation of output contact Termination of this functionOff-Line Monitor Screen Transfer Monitoring of Pre-error DataOff-Line Monitor Operating Method Title ScreenSystem Information Monitor Function common for each screen Filing operationMonitor Screen. Refer to c Off-Line AnalyzingOperation Status Monitor Screen Graph Trend Graph ScreenPage Mail Server Setting Check mailSystem Information Monitoring of Pre-error Data 4.5.1 Off-Line Analyzing Export Function common for each screen Filing operationDelete Data ImportText Convert Monitor Data information convertRight-clicking menu Offline Analyze on Wide area access mode System Information Data Pre-error DataFile Names Operating Status Monitor DataE-Mail mode and MN converter connection, it is not related How to change setting of FirewallHow to Change Setting of Firewall for Windows XP II In the case of G-50 Network Remote Connection Dialup Case of Windows XP Service Pack Page Page Trouble with Main Screen Troubleshooting?Trouble When Installing or Starting Trouble Cause RepairConnecting information Trouble Operation Monitor TroubleOperation Monitor Mail Communication Mode Trouble Malfunction Log TroubleOff-Line Monitor Trouble1 Specific troubles induced by E-mail connection modeFree contact of indoor unit Trouble Off-Line Monitor Trouble2

G-50A, MN Converter specifications

The Mitsubishi MN Converter, G-50A, represents a significant advancement in power conversion technology, designed to meet the rigorous demands of various industrial applications. This converter excels in delivering efficient and reliable performance while addressing specific user requirements.

One of the standout features of the G-50A is its high efficiency, typically exceeding 95%. This efficiency minimizes energy losses during the conversion process, significantly reducing operational costs and enhancing the overall economic viability of power-intensive operations. Its robust design ensures that it can handle fluctuating loads, making it suitable for diverse environments, from manufacturing plants to renewable energy systems.

The G-50A employs advanced digital signal processing (DSP) technology, enabling precise control of power conversion processes. This feature not only enhances the converter's performance but also allows for adaptive control strategies that can optimize energy use based on real-time conditions. As a result, users can experience improved reliability and performance consistency over time.

Thermal management is another critical characteristic of the G-50A. It utilizes a sophisticated cooling system that manages the heat generated during operation, ensuring that the unit remains within optimal temperature ranges. This prevents overheating and extends the lifespan of the converter, which is essential for maintaining operational uptime in demanding applications.

The modular design of the G-50A facilitates easier maintenance and scalability. Users can easily replace or upgrade individual components without the need for extensive downtime, significantly improving overall operational efficiency. Moreover, the compact footprint of the G-50A allows for flexible installation in various settings, making it adaptable to space-constrained environments.

In addition to its state-of-the-art technologies and features, the G-50A adheres to stringent international standards for safety and environmental compliance. This ensures that users can operate the converter with confidence, knowing that it meets necessary regulations while minimizing their environmental impact.

Overall, the Mitsubishi MN Converter, G-50A, combines high efficiency, advanced digital technology, and robust design attributes to provide a versatile and reliable power solution for a wide range of applications. Whether integrating into existing systems or establishing new processes, the G-50A stands as an innovative choice for enterprises seeking to optimize energy usage and enhance operational performance.