Mitsubishi G-50A, MN Converter manual Check mail, Mail Server Setting

Page 52

4.3.3 Check mail

*Mail Server Setting

In order to provide mail checking to the operation data mail-messaged from G-50 by utilizing Mail communication mode under online mode, the setting is required relating to the connection of the objective mail server.

(a)Clicking on the sub-menuMail server setting” of “Setting” on the menu bar displays Mail server setting screen.

(b)For lan connection, click on “LAN,” set the items relating to

mail servers, and click on .

Items to be set

-Pop server

-User name

-Password

:Ip address of mail servers for receiving :User name for mail receiving :Password for mail receiving

(c)For diaplup connection, click on ”Dialup Network,” set the

items relating to dialup and mail servers,and click on .

Items to be set

-Connection name:dialup connection name (requires to set the information on the provider to be connected by [dialup connection] from [control panel])

-Dialup user name:user name for dialup connection

-Dialup password :password for dialup connection

-

POP Server

:IP address of mail servers for receiving

-

User Name

:User name for mail receiving

-

Password

:Password for mail receiving

*When there are many amounts of data, this several hours case is in update of monitor data. We recommend you to set up so that interval time may be inputted into "POP Receive Interval" of "Mail Server Setting" and a mail check may be carried out periodically.

(A mail check is automatically performed at the set-up interval.)

(1)Click on to display the data list screen of Operation Monitor.

(2)Click on .

Initiates the checking of the operation monitor data mail for the mail server, and storing of the acquired data. During the data transfering and storing, the progress rate will be displayed.

(3) After completing of data tranffer and storing, the

numbers of received mail will be displayed.

(The numbers of the received mail counted here have

no relation with the numbers displayed on the monitor data.)

Clicking on

returns to the data list screen of Operation

Monitor.

 

*The capacity to store the data obtained by the maintenance tool counts for 2G-bite maximum. When the remaining storage capacity is getting insufficient during data reception by mail, Warning Screen will appear. In this case, suspend the mail checking, and delete unnecessary data on Offline Screen to keep a proper capacity.

51

Image 52
Contents Mitsubishi Operating ManualForeword Introduction of Maintenance ToolsOn-Line Monitorvia MN converter Case for remote connection Dialup connection mode On-Line Monitorvia G-50Wide area access mode Image of the Operation monitor mail communication modeRemote access method Off-Line MonitorHardware Requirements Required Operating EnvironmentRequired Materials Installation Setting Up the Maintenance Tools New setupSetting up the database MinutesSetting up the Maintenance Tools Running Maintenance Tool Upgrade Ending the Maintenance ToolUninstalling the Maintenance Tool Upgrade the DatabaseUninstalling the Maintenance Tools RE Change of computer name on PCStarting the Maintenance Tool Normal modeWide area access mode Starting and Ending the ApplicationCase for remote connection Page Click on Line will be disconnected Starting the On-Line MonitorG-50 connection Case for local connectionCase for remote connection Dialup Next Remote Monitor screen is displayedCase for remote connection E-mail Address book Using the Wide area access mode Starting the Off-Line MonitorCreating the Area name folder Online ConnectionCreating the Customer name folder Setting screen of air conditioning system Setting the Air conditioning system nameAbove Other setting Mail setting of maintenance tool PCSetting of Com port Offline AnalyzeOpen the Main Screen Ending the Off-Line MonitorOpen the Off-line Analyze Screen Design of Screen Terms for Each SectionOperating Method On-Line Monitor Operating Method On-Line Monitor Screen TransferFunction Chart Address Search MethodAddress Search Method Selection Automatic SearchManual Searching Automatic SearchingSearching Screen will appear Refer to 3.6 Connecting Information 3.6.2 2 Menu Bar Main ScreenConnecting Information Function Selection OperationsScreen Transfer Operation Items Performed HereScreen Functions and Operation 4Momentarily, the Connecting Information ScreenClick on Term and Explanation of Terminology Screen appear Operation Monitor Message Monitoring! Please wait for a moment. will appearMomentarily, the Operation Status Monitor Screen will appear Screen Functions and Operations 1Operation ButtonsAbout LM Adapter Introduction to the screen Tens digit Trend graph Ending the graph Screen function and operationMalfunction Log Message Monitoring. Please wait for a moment. will appearMessage Close the malfunction log display? will be displayed Optional Setting Self-Diagnosis MonitoringSending Command Monitoring of Pre-error DataCommand Screen and return to the Optional Setting Screen Refer to 3.6 Connecting Information 3.6.2 2Menu BarDate / Time Setting Main ScreenOperation Control Screen Functions and Operation Indoor unit, Lossnay unitScreen Functions and OperationBC Controller Starting of this function Free contact of indoor unitMonitoring of contact status Operation of output contact Termination of this functionMonitoring of Pre-error Data Off-Line Monitor Operating MethodOff-Line Monitor Screen Transfer Title ScreenSystem Information Monitor Function common for each screen Filing operationOperation Status Monitor Screen Off-Line AnalyzingMonitor Screen. Refer to c Graph Trend Graph ScreenPage Mail Server Setting Check mailSystem Information Monitoring of Pre-error Data 4.5.1 Off-Line Analyzing Function common for each screen Filing operation Delete DataExport ImportText Convert Monitor Data information convertRight-clicking menu Offline Analyze on Wide area access mode Pre-error Data File NamesSystem Information Data Operating Status Monitor DataHow to Change Setting of Firewall for Windows XP How to change setting of FirewallE-Mail mode and MN converter connection, it is not related II In the case of G-50 Network Remote Connection Dialup Case of Windows XP Service Pack Page Page Troubleshooting? Trouble When Installing or StartingTrouble with Main Screen Trouble Cause RepairConnecting information Trouble Operation Monitor TroubleOperation Monitor Mail Communication Mode Trouble Malfunction Log TroubleFree contact of indoor unit Trouble Specific troubles induced by E-mail connection modeOff-Line Monitor Trouble1 Off-Line Monitor Trouble2

G-50A, MN Converter specifications

The Mitsubishi MN Converter, G-50A, represents a significant advancement in power conversion technology, designed to meet the rigorous demands of various industrial applications. This converter excels in delivering efficient and reliable performance while addressing specific user requirements.

One of the standout features of the G-50A is its high efficiency, typically exceeding 95%. This efficiency minimizes energy losses during the conversion process, significantly reducing operational costs and enhancing the overall economic viability of power-intensive operations. Its robust design ensures that it can handle fluctuating loads, making it suitable for diverse environments, from manufacturing plants to renewable energy systems.

The G-50A employs advanced digital signal processing (DSP) technology, enabling precise control of power conversion processes. This feature not only enhances the converter's performance but also allows for adaptive control strategies that can optimize energy use based on real-time conditions. As a result, users can experience improved reliability and performance consistency over time.

Thermal management is another critical characteristic of the G-50A. It utilizes a sophisticated cooling system that manages the heat generated during operation, ensuring that the unit remains within optimal temperature ranges. This prevents overheating and extends the lifespan of the converter, which is essential for maintaining operational uptime in demanding applications.

The modular design of the G-50A facilitates easier maintenance and scalability. Users can easily replace or upgrade individual components without the need for extensive downtime, significantly improving overall operational efficiency. Moreover, the compact footprint of the G-50A allows for flexible installation in various settings, making it adaptable to space-constrained environments.

In addition to its state-of-the-art technologies and features, the G-50A adheres to stringent international standards for safety and environmental compliance. This ensures that users can operate the converter with confidence, knowing that it meets necessary regulations while minimizing their environmental impact.

Overall, the Mitsubishi MN Converter, G-50A, combines high efficiency, advanced digital technology, and robust design attributes to provide a versatile and reliable power solution for a wide range of applications. Whether integrating into existing systems or establishing new processes, the G-50A stands as an innovative choice for enterprises seeking to optimize energy usage and enhance operational performance.