Mitsubishi G-50A, MN Converter manual Operation of output contact, Termination of this function

Page 46

(2)Automatic monitoring

To automatically monitor the contact status of indoor units of No.1 ~ 50 repeatedly,

select the [Auto monitor] mode.

a)Click the [Auto monitor] button on the mode selection section.

The contact status of indoor units of No.1 ~ 50 will automatically be monitored, and this operation will be repeated.

The display for [Attribute], [Indoor unit contact mode], [Input contact (monitor)] and [Output contact (monitor/operation)] are identical to that in the manual monitoring.

*In the case to terminate the auto mode, selecting other mode will stop the monitoring.

3.11.3Operation of output contact

(1)Contact operation

To operate for the ON/OFF selection of the output contact of indoor units, select the [Operation contact] mode.

a)Click the [Operation contact] button on the mode selection section.

b)Click the [Output contact (ON/OFF)] button of the unit for which the ON/OFF of the output contact

is desired to be selected for change.

*The state where the button is being depressed (with bold letter) displays the present output status.

[Option] function

Affixing a check mark to [It checks before transmission] displays the warning screen as shown right before transmitting actual transmission command at the operation of output contact.

To continue the transmission, click [Yes].

When a check mark is not affixed, the transmission command will be transmitted at the clicking of the [Output contact (ON/OFF)] button simultaneously.

3.11.4 Termination of this function

(1)Clicking the [Close] button will close this screen and return to the main screen display.

45

Image 46
Contents Mitsubishi Operating ManualForeword Introduction of Maintenance ToolsOn-Line Monitorvia MN converter Case for remote connection Dialup connection mode On-Line Monitorvia G-50Remote access method Wide area access modeImage of the Operation monitor mail communication mode Off-Line MonitorHardware Requirements Required Operating EnvironmentRequired Materials Setting up the database InstallationSetting Up the Maintenance Tools New setup MinutesSetting up the Maintenance Tools Uninstalling the Maintenance Tool Running Maintenance Tool UpgradeEnding the Maintenance Tool Upgrade the DatabaseUninstalling the Maintenance Tools RE Change of computer name on PCWide area access mode Starting the Maintenance ToolNormal mode Starting and Ending the ApplicationCase for remote connection Page Click on Line will be disconnected Starting the On-Line MonitorG-50 connection Case for local connectionCase for remote connection Dialup Next Remote Monitor screen is displayedCase for remote connection E-mail Address book Using the Wide area access mode Starting the Off-Line MonitorCreating the Area name folder Online ConnectionCreating the Customer name folder Setting screen of air conditioning system Setting the Air conditioning system nameAbove Setting of Com port Other settingMail setting of maintenance tool PC Offline AnalyzeOpen the Main Screen Ending the Off-Line MonitorOpen the Off-line Analyze Screen Design of Screen Terms for Each SectionOperating Method On-Line Monitor Operating Method On-Line Monitor Screen TransferAddress Search Method Selection Function ChartAddress Search Method Automatic SearchManual Searching Automatic SearchingSearching Screen will appear Refer to 3.6 Connecting Information 3.6.2 2 Menu Bar Main ScreenScreen Transfer Operation Connecting InformationFunction Selection Operations Items Performed HereScreen Functions and Operation 4Momentarily, the Connecting Information ScreenClick on Term and Explanation of Terminology Screen appear Operation Monitor Message Monitoring! Please wait for a moment. will appearMomentarily, the Operation Status Monitor Screen will appear Screen Functions and Operations 1Operation ButtonsAbout LM Adapter Introduction to the screen Tens digit Trend graph Ending the graph Screen function and operationMalfunction Log Message Monitoring. Please wait for a moment. will appearMessage Close the malfunction log display? will be displayed Optional Setting Self-Diagnosis MonitoringCommand Screen and return to the Optional Setting Screen Sending CommandMonitoring of Pre-error Data Refer to 3.6 Connecting Information 3.6.2 2Menu BarDate / Time Setting Main ScreenOperation Control Screen Functions and Operation Indoor unit, Lossnay unitScreen Functions and OperationBC Controller Starting of this function Free contact of indoor unitMonitoring of contact status Operation of output contact Termination of this functionOff-Line Monitor Screen Transfer Monitoring of Pre-error DataOff-Line Monitor Operating Method Title ScreenSystem Information Monitor Function common for each screen Filing operationOperation Status Monitor Screen Off-Line AnalyzingMonitor Screen. Refer to c Graph Trend Graph ScreenPage Mail Server Setting Check mailSystem Information Monitoring of Pre-error Data 4.5.1 Off-Line Analyzing Export Function common for each screen Filing operationDelete Data ImportText Convert Monitor Data information convertRight-clicking menu Offline Analyze on Wide area access mode System Information Data Pre-error DataFile Names Operating Status Monitor DataHow to Change Setting of Firewall for Windows XP How to change setting of FirewallE-Mail mode and MN converter connection, it is not related II In the case of G-50 Network Remote Connection Dialup Case of Windows XP Service Pack Page Page Trouble with Main Screen Troubleshooting?Trouble When Installing or Starting Trouble Cause RepairConnecting information Trouble Operation Monitor TroubleOperation Monitor Mail Communication Mode Trouble Malfunction Log TroubleFree contact of indoor unit Trouble Specific troubles induced by E-mail connection modeOff-Line Monitor Trouble1 Off-Line Monitor Trouble2

G-50A, MN Converter specifications

The Mitsubishi MN Converter, G-50A, represents a significant advancement in power conversion technology, designed to meet the rigorous demands of various industrial applications. This converter excels in delivering efficient and reliable performance while addressing specific user requirements.

One of the standout features of the G-50A is its high efficiency, typically exceeding 95%. This efficiency minimizes energy losses during the conversion process, significantly reducing operational costs and enhancing the overall economic viability of power-intensive operations. Its robust design ensures that it can handle fluctuating loads, making it suitable for diverse environments, from manufacturing plants to renewable energy systems.

The G-50A employs advanced digital signal processing (DSP) technology, enabling precise control of power conversion processes. This feature not only enhances the converter's performance but also allows for adaptive control strategies that can optimize energy use based on real-time conditions. As a result, users can experience improved reliability and performance consistency over time.

Thermal management is another critical characteristic of the G-50A. It utilizes a sophisticated cooling system that manages the heat generated during operation, ensuring that the unit remains within optimal temperature ranges. This prevents overheating and extends the lifespan of the converter, which is essential for maintaining operational uptime in demanding applications.

The modular design of the G-50A facilitates easier maintenance and scalability. Users can easily replace or upgrade individual components without the need for extensive downtime, significantly improving overall operational efficiency. Moreover, the compact footprint of the G-50A allows for flexible installation in various settings, making it adaptable to space-constrained environments.

In addition to its state-of-the-art technologies and features, the G-50A adheres to stringent international standards for safety and environmental compliance. This ensures that users can operate the converter with confidence, knowing that it meets necessary regulations while minimizing their environmental impact.

Overall, the Mitsubishi MN Converter, G-50A, combines high efficiency, advanced digital technology, and robust design attributes to provide a versatile and reliable power solution for a wide range of applications. Whether integrating into existing systems or establishing new processes, the G-50A stands as an innovative choice for enterprises seeking to optimize energy usage and enhance operational performance.