Mitsubishi MN Converter, G-50A manual II In the case of G-50 Network Remote Connection Dialup

Page 61

(7)The [Local Area Connection Properties] screen will be displayed.

(8)Select the [Advanced] tab.

(9)Confirm that the checking column of [Internet Connection Firewall] has been affixed with a check mark.

(10)Click the [Settings - - -] button.

(11)The [Advanced Settings] screen will be displayed.

(12)Click the checking column of [Internet Mail Server [SMTP]] within the [Service] tab to affix a check mark.

(13)Click the [OK] button to close the [Advanced Settings] screen.

II)In the case of G-50 (Network) - Remote Connection (Dialup)

The procedure for the items of (1) ~ (3) is same as that of G-50 (Network) - Local Connection (LAN).

(4)Open the [Network Connection] screen.

(5)Select the Dialup name used for G-50 (Network) - Remote Connection1 (Dialup), and right-click to display the sub menu.

(6)Select [Properties] from the sub menu displayed.

(7) [Properties of (Dialup name)] will be displayed.

(8)Double-click the [Advanced] tab.

(9)Confirm that the checking column of [Internet Connection Firewall] has been affixed with a check mark.

(10)Click the [Settings - - -] button.

60

Image 61
Contents Operating Manual MitsubishiForeword Introduction of Maintenance ToolsOn-Line Monitorvia MN converter On-Line Monitorvia G-50 Case for remote connection Dialup connection modeImage of the Operation monitor mail communication mode Wide area access modeRemote access method Off-Line MonitorHardware Requirements Required Operating EnvironmentRequired Materials Setting Up the Maintenance Tools New setup InstallationSetting up the database MinutesSetting up the Maintenance Tools Ending the Maintenance Tool Running Maintenance Tool UpgradeUninstalling the Maintenance Tool Upgrade the DatabaseRE Change of computer name on PC Uninstalling the Maintenance ToolsNormal mode Starting the Maintenance ToolWide area access mode Starting and Ending the ApplicationCase for remote connection Page Click on Line will be disconnected Case for local connection Starting the On-Line MonitorG-50 connectionNext Remote Monitor screen is displayed Case for remote connection DialupCase for remote connection E-mail Address book Starting the Off-Line Monitor Using the Wide area access modeCreating the Area name folder Online ConnectionCreating the Customer name folder Setting screen of air conditioning system Setting the Air conditioning system nameAbove Mail setting of maintenance tool PC Other settingSetting of Com port Offline AnalyzeOpen the Main Screen Ending the Off-Line MonitorOpen the Off-line Analyze Screen Design of Screen Terms for Each SectionOperating Method On-Line Monitor Screen Transfer On-Line Monitor Operating MethodAddress Search Method Function ChartAddress Search Method Selection Automatic SearchManual Searching Automatic SearchingSearching Screen will appear Main Screen Refer to 3.6 Connecting Information 3.6.2 2 Menu BarFunction Selection Operations Connecting InformationScreen Transfer Operation Items Performed HereScreen Functions and Operation 4Momentarily, the Connecting Information ScreenClick on Term and Explanation of Terminology Screen appear Message Monitoring! Please wait for a moment. will appear Operation MonitorMomentarily, the Operation Status Monitor Screen will appear 1Operation Buttons Screen Functions and OperationsAbout LM Adapter Introduction to the screen Tens digit Trend graph Screen function and operation Ending the graphMessage Monitoring. Please wait for a moment. will appear Malfunction LogMessage Close the malfunction log display? will be displayed Self-Diagnosis Monitoring Optional SettingMonitoring of Pre-error Data Sending CommandCommand Screen and return to the Optional Setting Screen Refer to 3.6 Connecting Information 3.6.2 2Menu BarMain Screen Date / Time SettingScreen Functions and Operation Indoor unit, Lossnay unit Operation ControlScreen Functions and OperationBC Controller Starting of this function Free contact of indoor unitMonitoring of contact status Termination of this function Operation of output contactOff-Line Monitor Operating Method Monitoring of Pre-error DataOff-Line Monitor Screen Transfer Title ScreenFunction common for each screen Filing operation System Information MonitorOperation Status Monitor Screen Off-Line AnalyzingMonitor Screen. Refer to c Trend Graph Screen GraphPage Check mail Mail Server SettingSystem Information Monitoring of Pre-error Data 4.5.1 Off-Line Analyzing Delete Data Function common for each screen Filing operationExport ImportMonitor Data information convert Text ConvertRight-clicking menu Offline Analyze on Wide area access mode File Names Pre-error DataSystem Information Data Operating Status Monitor DataHow to Change Setting of Firewall for Windows XP How to change setting of FirewallE-Mail mode and MN converter connection, it is not related II In the case of G-50 Network Remote Connection Dialup Case of Windows XP Service Pack Page Page Trouble When Installing or Starting Troubleshooting?Trouble with Main Screen Trouble Cause RepairOperation Monitor Trouble Connecting information TroubleMalfunction Log Trouble Operation Monitor Mail Communication Mode TroubleFree contact of indoor unit Trouble Specific troubles induced by E-mail connection modeOff-Line Monitor Trouble1 Off-Line Monitor Trouble2

G-50A, MN Converter specifications

The Mitsubishi MN Converter, G-50A, represents a significant advancement in power conversion technology, designed to meet the rigorous demands of various industrial applications. This converter excels in delivering efficient and reliable performance while addressing specific user requirements.

One of the standout features of the G-50A is its high efficiency, typically exceeding 95%. This efficiency minimizes energy losses during the conversion process, significantly reducing operational costs and enhancing the overall economic viability of power-intensive operations. Its robust design ensures that it can handle fluctuating loads, making it suitable for diverse environments, from manufacturing plants to renewable energy systems.

The G-50A employs advanced digital signal processing (DSP) technology, enabling precise control of power conversion processes. This feature not only enhances the converter's performance but also allows for adaptive control strategies that can optimize energy use based on real-time conditions. As a result, users can experience improved reliability and performance consistency over time.

Thermal management is another critical characteristic of the G-50A. It utilizes a sophisticated cooling system that manages the heat generated during operation, ensuring that the unit remains within optimal temperature ranges. This prevents overheating and extends the lifespan of the converter, which is essential for maintaining operational uptime in demanding applications.

The modular design of the G-50A facilitates easier maintenance and scalability. Users can easily replace or upgrade individual components without the need for extensive downtime, significantly improving overall operational efficiency. Moreover, the compact footprint of the G-50A allows for flexible installation in various settings, making it adaptable to space-constrained environments.

In addition to its state-of-the-art technologies and features, the G-50A adheres to stringent international standards for safety and environmental compliance. This ensures that users can operate the converter with confidence, knowing that it meets necessary regulations while minimizing their environmental impact.

Overall, the Mitsubishi MN Converter, G-50A, combines high efficiency, advanced digital technology, and robust design attributes to provide a versatile and reliable power solution for a wide range of applications. Whether integrating into existing systems or establishing new processes, the G-50A stands as an innovative choice for enterprises seeking to optimize energy usage and enhance operational performance.