Sierra Monitor Corporation IZS31 operation manual Detection of the dirt on the electrode needle

Page 12

3.DC mode

Plasma ions or minus ions are continuously discharged. The parts other than the charged object need to be grounded to prevent them from being charged. The plasma and minus ions cannot be discharged simultaneously.

3-2. Detection of the dirt on the electrode needle

When the maintenance start-up signal is input, the ionizer detects if the static charge elimination capability is degraded due to the dirt on the electrode needle. If the electrode needle needs to be cleaned because of the degraded capability of the static charge, the maintenance LED lights up, and then the maintenance output signal is output. Because just installing the feed back sensor or auto balance sensor is not enough to detect if the static charge eliminating capability is degraded, regularly input the maintenance start-up signal to check the static charge elimination capability.

3-3. Indication/ Setting part description

⑪ ⑩ ⑨ ⑧ ⑦ ⑥ ⑤ ④ ③ ② ①

No.

Name

Type

Description

Power supply

LEDGreen

Lights up green when the power supply is turned ON.

 

indication

 

Flashes when the power supply voltage is not proper.

Sensor connecting

LEDGreen

Lights up when the feed back sensor and/or auto

 

indication

 

balance sensor is connected.

Minus indication

LEDBlue

 

Completion indication

LEDGreen

LED will change depending on the operating modes.

Plus indication

LED

4. See the selection of models and setting.

 

 

Orange

 

Indication for abnormal

LEDRed

Lights on red when overcurrent is applied to the

 

high voltage

 

electrode needle.

Sensor failure

LEDRed

Lights on red when the feed back sensor and/or auto

 

indication

 

balance sensor is not operating properly.

Maintenance indication

LEDRed

Flashes red when dirt on the electrode needle is

 

 

 

detected.

Maintenance level

Rotary

LED will change depending on the operating modes.

 

selecting switch

switch

4. See the selection of models and setting.

Frequency selecting

Rotary

 

 

switch

switch

 

Balance adjusting

Trimmer

This trimmer is used to adjust the ion balance when the

 

trimmer

 

auto balance sensor is not used.

11

Image 12
Contents IZS31 Series Doc. No.IZ*-OMK0015 BInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions Installation To 1.5 NmWiring and piping Environment Installation Installation of Ionizer bodyAttached M4 threads Intermediate bracket M5 threadsInstallation of sensor Installation of sensor headM3 screws Metal plate Operation mode Function descriptionSee the selection of models and setting Detection of the dirt on the electrode needle.Selection and setting of equipment .Sensing DC mode„ Connection with the power supply for I/O signal OUT4„ Alarm LED ・・・ Failure of the ionizer is displayed „ ION LED ・・・ The charged condition of the work is displayedAlarm Timing chart „ Timing chart with a normal operationPulse DC mode Auto ManualPower supply cable for „ Connection power supply for I/O signalFunction Ionizer drive„ Alarm LED ・・・ Failure of the ionizer will be indicated Goes out② Auto operation (b)W/o auto balance sensor.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP .Specifications [Electrode cartridge quantity and weight].Ionizer 300 380 620 780 1100 1260 1500 1900 2300„ Sensor monitor output When feed back sensor is used .Sensor„ Detection range of Feedback sensor