Sierra Monitor Corporation IZS31 operation manual Metal plate

Page 10

„Auto balance sensor

Horizontally place the auto balance sensor under the ionizer and face its metal plate upward. Because

the ion balance will be changed depending on the installation height, install the sensor on the same level with a workpiece as much as possible. The auto balance sensor can be removed once the ion balance adjustment is completed.

Keep the height between the auto balance sensor and ionizer within the installation height stated in 2-1.

Mount the head sensor with 2 pieces of M3 screws (sold separately).

Metal plate

2.Installation of sensor amp

A sensor amp should be mounted with 2 pieces of M3 screws (sold separately).

Do not pull a cable out of the sensor amp. If the cable is pulled with a strong force, the sensor amp might

be damaged or its wires might be broken.

Be sure to ground the sensor amp case. (Resistance between the sensor amp case and the earth ground should be 100Ω or less.) Because the sensor amp case surface is treated with conductive plating, FG wiring is not necessary when the sensor amp case is connected to the mounting surface of the grounded unit. If the mounting surface is insulated with painting or being anodized, be sure to connect the FG wiring for grounding.

M3 threads

Head side

Class D ground

Sensor

2-3. Connection of cable

1.Insert the modular plug of power supply cable IZS31-CP into the modular jack for indicating [power] on the ionizer body. A lever will snap when the modular plug is correctly locked. Fix cables with a tie wrap or other measures in the vicinity of connection not to apply compulsive force to the modular jack and plug.

9

Image 10
Contents IZS31 Series Doc. No.IZ*-OMK0015 BInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions Installation To 1.5 NmWiring and piping Environment Installation of Ionizer body InstallationAttached M4 threads Intermediate bracket M5 threadsInstallation of sensor head Installation of sensorM3 screws Metal plate Operation mode Function descriptionSee the selection of models and setting Detection of the dirt on the electrode needle.Selection and setting of equipment .Sensing DC mode„ Connection with the power supply for I/O signal OUT4„ Alarm LED ・・・ Failure of the ionizer is displayed „ ION LED ・・・ The charged condition of the work is displayedAlarm Timing chart „ Timing chart with a normal operationPulse DC mode Auto ManualFunction Power supply cable for„ Connection power supply for I/O signal Ionizer drive„ Alarm LED ・・・ Failure of the ionizer will be indicated Goes out② Auto operation (b)W/o auto balance sensor.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP .Ionizer .Specifications[Electrode cartridge quantity and weight] 300 380 620 780 1100 1260 1500 1900 2300.Sensor „ Sensor monitor output When feed back sensor is used„ Detection range of Feedback sensor