Sierra Monitor Corporation IZS31 operation manual Function, Power supply cable for, Ionizer drive

Page 18

5. Setting of the frequency selecting switch Select the ion-production frequency.

Ion-production

Switch setting

frequency

 

1Hz

0

3Hz

1

5Hz

2

10H

3

15Hz

4

20Hz

5

30Hz

6

60Hz

7

6. Wiring of the power supply cables

Connect a dedicated power supply cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

„ Connection power supply

for ionizer drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Lead wire color

Description

Direction

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Power supply

 

 

 

 

of signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC1+

Brown

Power supply

power supply cable for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC24V

 

ionizer drive

 

 

Brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC1-

Blue

Power supply

 

 

Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND[FG]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT4

Dark Green

Sensor monitor

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Be sure to ground DC1(-)Blue. (Resistance between the lead wire and the earth ground should be 100Ω or less.) If not, it may break the ionizer.

„Connection power supply for I/O signal

No

Lead wire

Description

Direction

 

color

 

of signal

DC2+

Red

Power supply DC24V

DC2-

Black

Power supply GND

IN1

Light

Discharge-stop signal

 

 

Green

 

 

 

 

 

 

 

 

 

IN2

Gray

Maintenance start-up

 

 

signal

 

 

 

White

Orange

OUT1

Pink

Completion signal for

 

 

static charge elimination

 

 

 

OUT2

Yellow

Maintenance output

 

 

signal

 

 

 

OUT3

Purple

Signal for failure

 

 

 

 

 

 

 

Function

Power supply cable for I/O signal

Signal for starting/ stopping the discharge NPN specOperation will begin when it is connected with DC2-)[Black.

PNP specOperation will begin when it is connected with DC2+)[Red.

A signal that is input when the maintenance of the electrode needle is necessary.

Outputs when the dirt on the electrode needle is detected.

Outputs when the maintenance of the electrode needle is necessary.

Outputs in case of abnormal high voltage and sensor and/or CPU failure.

(B contact output)

Wires that are minimum required to operate the ionizer. △ : Wires that are required to use the functions.

- : Wires that are not necessary with the pulse DC mode. These wires should not be short-circuited with other cables.

7.Air piping

When the piping is only connected to one port, the other unused port should be plugged with the M-5P that is packaged together with the ionizer.

17

Image 18
Contents IZS31 Series Doc. No.IZ*-OMK0015 BInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions Installation To 1.5 NmWiring and piping Environment Installation Installation of Ionizer bodyAttached M4 threads Intermediate bracket M5 threadsInstallation of sensor Installation of sensor headM3 screws Metal plate Operation mode Function descriptionSee the selection of models and setting Detection of the dirt on the electrode needle.Selection and setting of equipment .Sensing DC mode„ Connection with the power supply for I/O signal OUT4„ Alarm LED ・・・ Failure of the ionizer is displayed „ ION LED ・・・ The charged condition of the work is displayedAlarm Timing chart „ Timing chart with a normal operationPulse DC mode Auto ManualFunction Power supply cable for„ Connection power supply for I/O signal Ionizer drive„ Alarm LED ・・・ Failure of the ionizer will be indicated Goes out② Auto operation (b)W/o auto balance sensor.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP .Ionizer .Specifications[Electrode cartridge quantity and weight] 300 380 620 780 1100 1260 1500 1900 2300„ Sensor monitor output When feed back sensor is used .Sensor„ Detection range of Feedback sensor