6. Wiring of the power supply cable
・Connect dedicated power supply cables.
Connection with the power supply for ionizer operation
Symbol | Cable | Cable name | Connection | Description |
| color |
|
|
|
DC1(+) | Brown | Power supply DC24V | ○ | Power supply cable for |
Blue | Power supply GND[FG] | ○ | ionizer operation | |
OUT4 | Dark | Sensor monitor output |
| Charged potential of the |
| Green |
| △ | work is output with |
|
|
|
| analog signal (1 to 5V) |
DC Power supply
Brown
Blue
Ground
※Be sure to ground
Connection with the power supply for I/O signal
Symbol | Cable | Cable name | Conne |
| color |
| ction |
DC2(+) | Red | Power supply DC24V | ○ |
Black | Power supply GND | ○ | |
IN1 | Light |
| |
| Green |
|
|
|
|
| ○ |
|
|
|
|
IN2 | Gray | Maintenance | △ |
|
|
| |
|
|
|
|
- | White | - | - |
- | Orange | - | - |
OUT1 | Pink | Completion signal for |
|
|
| static charge elimination | △ |
|
|
|
|
OUT2 | Yellow | Maintenance output signal | △ |
|
|
| |
|
|
|
|
OUT3 | Purple | Signal for failure |
|
|
|
| △ |
|
|
|
|
Description
Power supply cable for I/O signal
Signal for starting/ stopping the discharge
(NPN spec)Operation will begin when it is connected with
(PNP spec)Operation will begin when it is connected with DC2(+)[Red].
A signal that is input when the maintenance of the electrode needle is necessary.
-
-
Outputs when the charged potential of the work is
Outputs when the maintenance of the electrode needle is necessary.
Outputs in case of abnormal high voltage and sensor and/or CPU failure.
(B contact output)
○: Wires that are minimum required to operate the ionizer. △ : Wires that are required to use the functions.
-: Wires that are not necessary with the sensing DC mode. These wires should not be
7.Air piping
・When the piping is only connected to one port, the other unused port should be plugged with the
13