Sierra Monitor Corporation IZS31 „ ION LED ・・・ The charged condition of the work is displayed

Page 15

8.LED display

„POWER LED ・・・ The power supply input and the connection of the sensors are displayed.

LED name

 

Functions

POWER

MAIN

Lights up when the power supply is applied. (Green)

 

 

(Flashes when wrong power supply is applied.

 

SNSR

Lights up when the feed back sensor is connected.(Green)

„ION LED ・・・ The charged condition of the work is displayed.

LED name

 

Functions

ION

The charged potential of the work is positive.Orange

 

OK

The charged potential of the work is low.Green

 

The charge potential of the work is negative.Blue

The charged condition of the work can be identified with the LED display.

Charged polarity of work

LED

 

Charged potential of the work

 

+ OK

-

 

 

 

 

Plus

■□□ More than +400V

light on

 

□□ +100V to +400V

flash with 4 Hz

 

■□ +30V to +100V

light out

static charge elimination

□■□ +30V to -30V

 

 

□■-30 to -100V

 

 

□□-100 to -400V

 

Minus

□□■ More than -400V

 

„ ALARM LED ・・・ Failure of the ionizer is displayed.

LED name

 

Functions

ALARM

HV

Lights up when overcurrent is applied to the electrode

 

 

needle.Red

 

SNSR

Lights up when the feed back sensor doesn’t work properly.

 

 

Red

 

NDL

Lights up when dirt on the electrode needle is detected.

 

CHECK

Red

 

 

Flashes when the dirt is being detected.

14

Image 15
Contents Doc. No.IZ*-OMK0015 B IZS31 SeriesInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions To 1.5 Nm InstallationWiring and piping Environment Installation Installation of Ionizer bodyAttached M4 threads M5 threads Intermediate bracketInstallation of sensor Installation of sensor headM3 screws Metal plate Function description Operation modeDetection of the dirt on the electrode needle See the selection of models and setting.Sensing DC mode .Selection and setting of equipmentOUT4 „ Connection with the power supply for I/O signal„ ION LED ・・・ The charged condition of the work is displayed „ Alarm LED ・・・ Failure of the ionizer is displayedTiming chart „ Timing chart with a normal operation AlarmAuto Manual Pulse DC modeIonizer drive Power supply cable for„ Connection power supply for I/O signal FunctionGoes out „ Alarm LED ・・・ Failure of the ionizer will be indicated(b)W/o auto balance sensor ② Auto operation.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP 300 380 620 780 1100 1260 1500 1900 2300 .Specifications[Electrode cartridge quantity and weight] .Ionizer„ Sensor monitor output When feed back sensor is used .Sensor„ Detection range of Feedback sensor