Sierra Monitor Corporation IZS31 operation manual ② Auto operation, (b)W/o auto balance sensor

Page 20

9. Alarm

Type of alarm

Description

How to reset

Abnormal high voltage

Notifies when overcurrent such as high voltage

Turn off the power supply to solve the problem.

 

leakage occurs.The ion-discharge-output is

Once it’s solved, apply the power supply again.

 

stopped, HV ALRM sets off and output the signal

Or turn on and off the discharge-stop signal.

 

for failure.

 

Sensor failure

Notifies that the auto balance sensor doesn’t

Turn off the power supply to solve the problem.

 

work properly. SNSR ALARM lights up, and the

Once it’s solved, apply the power supply again.

 

signal for sensor failure is output.

Or turn on and off the discharge-stop signal.

CPU failure

Notifies that CPU fails due to noise. All LEDs

Turn off the power supply to solve the problem.

 

Flashes, and the signal for CPU failure is output.

Once it’s solved, apply the power supply again.

 

 

Or turn on and off the discharge-stop signal.

Electrode needle

Notifies when the maintenance of the electrode

Turn off the power supply and clean the

maintenance

needle is necessary. NDL CHECK ALARM lights

electrode needle. Then apply the power supply.

 

up, and the maintenance output signal is output.

 

10.Timing chart

„Timing chart with a normal operation

 

 

ON

 

 

 

 

Power supply DC24V

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

ON

(Operation)

 

 

Discharge-stop signal

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

ON

(Discharge)

 

 

State of ion discharge

OFF

 

 

 

 

 

 

 

 

 

 

 

„Timing chart when the dirt on the electrode needle is detectedadjust ion balance

(a)With auto balance sensor

Manual operation

 

 

 

ON

 

 

 

 

 

 

 

 

Power supply DC24V

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

(Operation)

 

 

 

 

 

 

Discharge-stop signal

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

Completion signal for

Output

ON

(Contamination detecting of electrode needle / Ion balance is being adjusted.)

OFF

 

 

 

 

 

 

2s

Static charge elimination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

 

ON

(SW ON)

 

100ms or more

Start-up signal

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

 

ON

(SW ON)

 

 

 

 

 

Output signal

Output OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance indication

 

ON

(Lighting)

 

 

Blink

(NDL CHECK ALARM)

LED

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ionizer

Contamination detecting

 

 

 

 

 

Detection is executed when the

of electrode needle

 

 

 

 

 

 

maintenance level selecting switch,

operation

 

 

 

 

 

 

 

 

H, M or L is selected.

Adjust ion balance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto operation

 

 

Input

ON

 

 

 

 

 

 

 

 

Power supply DC24V

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Discharge-stop signal

 

ON

(Operation)

 

 

 

 

 

 

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

Completion signal for

Output

ON

(Contamination detecting of electrode needle)

OFF

 

 

 

 

 

 

2s

Static charge elimination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

 

ON

(SW ON)

 

100ms or more

 

 

Input

OFF

 

 

 

 

 

 

 

 

Start-up signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

 

ON

(SW ON)

 

 

 

 

 

Output signal

Output

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance indication

 

ON

(Lighting)

 

Blink

(NDL CHECK ALARM)

LED

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contamination detecting

 

 

 

 

 

 

Detection is executed when the

Ionizer

of electrode needle

 

 

 

 

 

 

 

maintenance level selecting switch,

operation

 

 

 

 

 

 

 

 

 

H, M or L is selected.

Adjust ion balance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(b)W/o auto balance sensor

 

 

 

ON

 

 

 

 

 

 

 

 

Power supply DC24V

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

(Operation)

 

 

 

 

 

 

Discharge-stop signal

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

Completion signal for

 

ON

(Contamination detecting of electrode needle)

Static charge eliminationOutput OFF

 

 

 

 

 

 

2s

 

 

 

 

 

 

 

 

Maintenance

 

ON

(SW ON)

 

100ms or more

Start-up signal

Input

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance

 

ON

(SW ON)

 

 

 

 

 

Output signal

Output OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance indication

 

ON

(Lighting)

 

Blink

 

 

(NDL CHECK ALARM)

LED

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ionizer

Contamination detecting

 

 

 

 

 

 

Detection is executed when the

of electrode needle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

maintenance level selecting switch,

 

 

 

 

 

 

 

 

 

 

行)

operation

 

 

 

 

 

 

 

 

 

H, M or L is selected.

 

 

 

 

 

 

 

 

 

Adjust ion balance

ON and OFF status will be changed depending on the situation.

The completion signal for static charge elimination is output while the dirt on the electrode needle is being detected

Because ions are discharged from the ionizer when the electrode needle is being detected, the workpiece might be charged. Therefore, the workpieces should not be mounted when the detection is executed.

19

Image 20
Contents IZS31 Series Doc. No.IZ*-OMK0015 BInstallation of Ionizer body ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Safety instructions Installation To 1.5 NmWiring and piping Environment Attached M4 threads InstallationInstallation of Ionizer body Intermediate bracket M5 threadsM3 screws Installation of sensorInstallation of sensor head Metal plate Operation mode Function descriptionSee the selection of models and setting Detection of the dirt on the electrode needle.Selection and setting of equipment .Sensing DC mode„ Connection with the power supply for I/O signal OUT4„ Alarm LED ・・・ Failure of the ionizer is displayed „ ION LED ・・・ The charged condition of the work is displayedAlarm Timing chart „ Timing chart with a normal operationPulse DC mode Auto ManualPower supply cable for „ Connection power supply for I/O signalFunction Ionizer drive„ Alarm LED ・・・ Failure of the ionizer will be indicated Goes out② Auto operation (b)W/o auto balance sensor.DC mode „ ION LED ・・・ The discharged ion polarity is displayed Power supply cable connection circuit PNP .Specifications [Electrode cartridge quantity and weight].Ionizer 300 380 620 780 1100 1260 1500 1900 2300„ Detection range of Feedback sensor „ Sensor monitor output When feed back sensor is used.Sensor